Tesis Doctoral
DOI
https://doi.org/10.11606/T.5.2011.tde-02082011-160101
Documento
Autor
Nombre completo
Henrique Melo de Campos Gurgel
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2011
Director
Tribunal
Croci, Alberto Tesconi (Presidente)
Oliveira, Reginaldo Perilo
Picado, Celso Herminio Ferraz
Queiroz, Roberto Dantas
Vicente, José Ricardo Negreiros
Título en portugués
Posicionamento do componente acetabular na artroplastia total do quadril com e sem o auxílio de um sistema de navegação computadorizado: estudo comparativo prospectivo randomizado
Palabras clave en portugués
Acetábulo
Artroplastia
ATQ
Navegação
Quadril
Resumen en portugués
Em um estudo prospectivo e randomizado sobre o posicionamento do componente acetabular na artroplastia total do quadril, 20 quadris foram operados com o auxílio da navegação livre de métodos de imagem e 20 quadris foram operados através do método convencional. Todas as cirurgias foram realizadas pelo mesmo cirurgião com o paciente em decúbito lateral. A avaliação do posicionamento foi feita através da medição tomográfica pós-operatória dos ângulos de anteversão e inclinação cirúrgicos e análise da zona de segurança. Os resultados obtidos foram similares em todas as comparações: anteversão média de 17,4o no grupo navegado e 14,5o no grupo convencional (p=0,215), inclinação média de 41,7o no grupo navegado e 42,2o no grupo convencional (p=0,633), desvio médio do objetivo da anteversão (15o) de 5,5o no grupo navegado e 6,6o no grupo convencional (p=0,429), desvio médio do objetivo da inclinação (40o) de 3o no grupo navegado e 3,2o no grupo convencional (p=0,783) e localização dentro da zona de segurança de 90% no grupo navegado e 80% no grupo convencional (p=0,661). A avaliação tomográfica pós-operatória do posicionamento acetabular na artroplastia total de quadril realizada com o paciente em decúbito lateral foi semelhante ao se comparar a técnica navegada com a técnica convencional
Título en inglés
Acetabular component positioning in total hip arthroplasty with and without a computer-assisted system: a prospective, randomised and controlled study
Palabras clave en inglés
Acetabulum
Arthroplasty
Hip
Navigation
THA
Resumen en inglés
In a prospective and randomised study of the acetabular component position in total hip arthroplasty, 20 hips were operated using imageless navigation and 20 hips were operated using the conventional method. The same surgeon performed all the operations with the patient in the lateral position. The correct position of the acetabular component was evaluated with computed tomography performed after the surgeries, measuring the operative anteversion angle and the operative inclination angle and determining the cases inside the safe zone. The results were similar in all the analyses: a mean anteversion of 17.4o in the navigated group and 14.5o in the conventional group (p=0.215), a mean inclination of 41.7o in the navigated group and 42.2o in the conventional group (p=0.633), a mean deviation from the desired anteversion (15o) of 5.5o in the navigated group and 6.6o in the conventional group (p=0.429), a mean deviation from the desired inclination (40o) of 3o in the navigated group and 3.2o in the conventional group (p=0.783), and location inside the safe zone of 90% in the navigated group and 80% in the conventional group (p=0.661). The acetabular component positions tomography analyses in total hip arthroplasty, performed with the patient in the lateral position, were similar whether using imageless navigation or performing it conventionally
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2011-08-03
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.