• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.5.2009.tde-02062009-090754
Documento
Autor
Nombre completo
Kadidja Claudia Maia e Machado
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2009
Director
Tribunal
Barros Filho, Tarcisio Eloy Pessoa de (Presidente)
Bolliger Neto, Raul
Carvalho, Camilla de Freitas
Título en portugués
O uso de placa oclusal no tratamento da disfunção temporomandibular: análise eletromiográfica em 26 pacientes
Palabras clave en portugués
Eletromiografia
Placas oclusais
Síndrome da disfunção da articulação temporomandibular
Resumen en portugués
INTRODUÇÃO: O tratamento das disfunções temporomandibulares não segue um padrão aceito na literatura nem na prática clínica. Os efeitos desse tratamento sobre a musculatura mastigatória apresentam-se ainda de maneira não concreta ao profissional. OBJETIVO: Avaliar a atividade eletromiográfica do masséter, direito e esquerdo, em repouso e em contração, além do comportamento elétrico, do músculo em questão, antes e após o uso de placa oclusal, por três meses, em sete momentos. MÉTODOS: Este estudo experimental e prospectivo foi realizado entre setembro de 2006 e junho de 2007. A atividade elétrica foi avaliada através de eletromiografia de superfície em amostra constituída por 26 pacientes, sendo 22 do gênero feminino e 4 do masculino, com disfunção temporomandibular, em sete momentos: antes do uso da placa oclusal, após 7, 14, 21, 30, 60 e 90 dias de uso. Foram comparadas as atividades elétricas entre masséter direito e esquerdo e o comportamento elétrico do músculo nos sete momentos de avaliação, em repouso e em contração. RESULTADOS: Os dados foram analisados estatisticamente. Não houve diferença estatisticamente significante entre as atividades do masséter direito e esquerdo, em repouso (p=0,848) e em contração (p=0,658), durante as avaliações. Nos sete momentos, em repouso, houve diminuição da atividade elétrica do masséter (p=0,000), apresentaram diferenças estatisticamente significantes os momentos 7 e 21 dias (p=0,048); 7 e 30 dias (p=0,005); 7 e 90 dias (p=0,001) e 14 e 90 dias (p=0,032). Em contração, também houve diminuição da atividade eletromiográfica (p=0,000). As diferenças estatisticamente significantes aconteceram entre os momentos: Antes e 7 dias (p=0,017) e Antes e 90 dias (p=0,007). CONCLUSÕES: O uso de placa oclusal não alterou a atividade eletromiográfica entre o masséter direito e esquerdo. O uso de placa oclusal causou diminuição da atividade eletromiográfica em repouso e em contração, nos sete momentos de avaliação.
Título en inglés
The using of occlusal splints on temporomandibular dysfunction therapy: electromyography analysis on 26 patients
Palabras clave en inglés
Electromyography
Occlusal splints
Temporomandibular joint dysfunction syndrome
Resumen en inglés
INTRODUCTION: Temporomandibular dysfunction treatment does not follow an accepted pattern in the literature and at the clinical practice. Treatment effects, on chewing muscles, still present themselves in a non-concrete way to professionals. OBJECTIVES: To analyze right and left masseter electromyographyc activity, as well as their electric behavior, prior to and after the use of occlusal splint for a three-month period in seven different moments. METHODS: This experimental and prospective study has been done between September 2006 and June 2007. The electric activity was evaluated through sample surface electromyography of 26 patients, 22 female genders and 4 male genders with temporomandibular dysfunction in 7 different moments: before the occlusal splint usage and after 7, 14, 21, 30, 60 and 90 days of usage. The electric activity has been compared along the right and left masseter and the muscle electric behavior on the seven evaluation moments, relaxed and under contraction. OUTCOMES: Data has been analyzed statistically. There has not been statistic differences among right and left masseters; relaxed (p=0,848) and contracted (p=0,658), during evaluations. On the seven moments, when relaxed, there was a decrease on the masseter electric activity; statistically significant differences are displayed on the 7 and 21 day-moments (p=0,048); 7 and 30 day-moments (p=0,005); 7 and 90 day-moments (p=0,001) and 14 and 90 day-moments (p=0,032). Under contraction, there has been a decrease on the electromyographyc activity as well (p=0,000). The significant statistically differences took place between the moments: before and 7days (p=0,017) and before and 90 days (p=0,007). CONCLUSIONS: The occlusal splint usage did not alter the electromyographyc activity between right and left masseter. The occlusal splint usage decreasing the electromyographyc activity under contraction and relaxed, on seven moments.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
kadidjacmmachado.pdf (1.33 Mbytes)
Fecha de Publicación
2009-06-09
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.