• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.5.2006.tde-30012007-094837
Document
Auteur
Nom complet
Rita de Cassia Alam Machado
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2006
Directeur
Jury
Brizot, Maria de Lourdes (Président)
Bittar, Roberto Eduardo
Boyaciyan, Krikor
Titre en portugais
Gestações gemelares com pesos discordantes: estudo da predição ultra-sonográfica e dos resultados neonatais
Mots-clés en portugais
Gêmeos
Morbidade
Peso fetal
Recém-nascido pequeno para idade gestacional
Retardo de crescimento fetal
Ultra-sonografia pré-natal
Resumé en portugais
A gemelaridade apresenta algumas intercorrências específicas, como a discordância de peso entre fetos e recém-nascidos (RNs). O objetivo do presente estudo foi predizer a discordância de peso do exame ultra-sonográfico comparada à do parto e avaliar a morbidade e a mortalidade neonatais nas gestações gemelares discordantes quanto ao peso. Este foi um estudo retrospectivo, com levantamento dos casos do período de 1998 a 2004, no Setor de Gestações Múltiplas da Clínica Obstétrica do HCFMUSP. Na avaliação da predição ultra-sonográfica, foram inseridas 221 gestações gemelares e, na avaliação da morbidade e da mortalidade, 151 gestações com partos nessa instituição. A discordância de peso foi definida como >= 20%, sendo excluídos os casos de malformações fetais (n=43) e da Síndrome da transfusão feto-fetal (n=24). Para análise da adequação do peso ao nascimento, utilizou-se a curva de Alexander et al., 1998, para gêmeos. No estudo da predição, foram utilizados quatro intervalos de tempo em relação ao parto (0 a 7 dias - n = 96; 8 a 14 dias - n = 66; 15 a 21 dias - n = 58; 22 a 28 dias - n = 59 gestações), somando 279 avaliações. No grupo de 0 a 7 dias, a estimativa da sensibilidade foi de 93,6%, especificidade de 79,4%, valor preditivo positivo de 89,2%, valor preditivo negativo de 87,1% e acurácia de 88,6%. Nos demais grupos, a sensibilidade e a acurácia foram de 95,8% e 84,9%, 95,6% e 84,5%, 90,9% e 84,8%, respectivamente. Em relação à morbidade, 111 gestações eram concordantes (73,5%) e 40 discordantes quanto ao peso. No grupo discordante, 75% das gestações gemelares apresentaram pelo menos um recém-nascido com Restrição de Crescimento Fetal (RCF). Nesta análise, as gestações gemelares concordantes monocoriônicas obtiveram menor média de idade gestacional no parto (34,3 versus 36,2 semanas, p=0,004), menor peso médio (2067 versus 2334 gramas, p=0,0016) e maior tempo de internação (10,6 versus 7,3 dias, p=0,0023) que as gestações concordantes dicoriônicas. Nas gestações discordantes, não houve diferença significativa em relação à corionicidade. As gestações discordantes, com pelo menos um RN abaixo do percentil 10, apresentaram menor média de idade gestacional (35,2 versus 36,8 semanas, p=0,009) e maior tempo de internação (17,5 versus 8,2 dias, p=0,026). Não foi observada diferença significativa de morbidade e mortalidade entre RNs concordantes e discordantes, com pesos entre os percentis 10 e 90. Os fetos menores das gestações discordantes demonstraram maior freqüência de índice de Apgar inferior a 7 (27,5% versus 7,5%, p=0,01). A avaliação da mortalidade não demonstrou diferença significativa em relação aos grupos concordantes (3,7%) e discordantes (4,5%; p = 1,00). No presente estudo, conclui-se que os quatro grupos apresentaram adequada correlação entre a discordância de peso à ultra-sonografia e no nascimento, porém com melhor predição até sete dias antes do parto. A morbidade neonatal esteve relacionada à RCF do menor feto. A discordância de peso e a corionicidade não interferiram na mortalidade neonatal.
Titre en anglais
Twin growth discordance: sonographic prediction and factors related to perinatal outcome
Mots-clés en anglais
Fetal growth retardation
Fetal weight
Morbidity
Prenatal ultrasonography
Small for gestational age infant
Twins
Resumé en anglais
The aim of this study was to evaluate the ability of prenatal ultrasound scans to predict fetal growth discordance in twin pregnancies and perinatal morbidity/mortality associated with these cases. This was a retrospective study (1998-2004) involving twin pregnancies that were scanned and had their delivery at our Institution (HCFMUSP). Cases with fetal malformations (n=43) or twin to twin transfusion syndrome (n=24) were excluded. The study of ultrasound scans consisted of 221 twin pregnancies. The final morbidity/mortality study group consisted of 151 twin pregnancies. Birth weight was evaluated based on twin growth charts published by Alexander et al (1998) and weight discordance as a difference >= 20%. Small for gestacional age (SGA) was defined as birth weight below the 10th centile. The study of ultrasonographic prediction of interwin discordance was made using four different intervals between ultrasound examination and delivery (0 to 7 days, n = 96; 8 to 14 days, n = 66; 15 to 21 days, n = 58; 22 to 28 days, n = 59 pregnancies), with a total of 279 ultrasound examinations. In group 0 to 7 days, the sensitivity was 93,6%, specificity was 79,4%, positive predicted values was 89,2%, negative predicted values was 87,1% and accuracy was 88,6%. In the groups 8 to 14 days, 15 to 21 days and 22 to 28 days the sensitivity and accuracy were 95,8% and 84,9%, 95,6% and 84,5%, 90,9% and 84,8%, respectively. Birthweight discordance was observed in 40 sets of twins (26.5%) and 12 cases were monochorionic MC (30%). Twenty five cases (22.5%) in the non discordant group were MC. In the non discordant group, monochorionic pregnancies showed lower gestational age at delivery (34.3 versus 36.2 wks, p=0.004), lower mean birth weight (2067g versus 2334g, p=0.0016) and longer length of stay in hospital (10.6 versus 7.3 days, p=0.0023) compared to dichorionic twins. In the group with twin birthweight discordance, there were no significant differences between MC and DC pregnancies and 75% of the cases had at least one newborn with SGA. These cases were showed lower gestational age at delivery (35.2 versus 36.8wks, p=0.009) and longer length of stay in hospital (17.5 versus 8.2 days, p=0.026). In the discordant group, the smaller twin had a higher frequency of first minute Apgar score < 7 (27.5% versus 7.5%, p=0.01). Perinatal mortality rate was similar in both groups (discordant 4.5% and concordant 3.7%, p=1.0). There were no significant differences in morbidity and mortality between concordant and discordant twins when birth weight was between the 10 th and 90 th centile. In conclusion, there was a good correlation between fetal growth discordance predicted by prenatal scan and actual birth weight discordance. Neonatal morbidity was related to SGA. Excluding fetal malformation and TTTS cases, birth weight discordance in twin pregnancies is not a significantly associated with neonatal mortality.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2007-02-05
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.