• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.5.2014.tde-20052014-105722
Documento
Autor
Nombre completo
Rimena de Melo Germano da Silva
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2013
Director
Tribunal
Zugaib, Marcelo (Presidente)
Fonsêca, Eduardo Sérgio Valério Borges da
Francisco, Rossana Pulcineli Vieira
Título en portugués
Comparação do comprimento do úmero em fetos portadores de Síndrome de Down com o comprimento do úmero em fetos normais
Palabras clave en portugués
Estudos de casos e controles
Programas de rastreamento
Sensibilidade e especificidade
Síndrome de Down/ultrassonografia
Ultrassonografia pré-natal
Úmero/embriologia
Úmero/ultrassonografia
Resumen en portugués
Objetivo: Comparar o comprimento do úmero em fetos portadores de síndrome de Down (T21) com o comprimento do úmero em fetos normais, utilizando instrumentos de referência da população local. Método: Estudo caso-controle retrospectivo que comparou o comprimento do úmero de fetos normais com os fetos com T21, entre 18 semanas e 23 semanas e 6 dias. Os exames dos fetos com T21 foram realizados entre 1994 e 2012. Os controles normais foram avaliados entre 2007 e 2009. Foram analisadas as médias, medianas e desvios-padrão da idade materna, idade gestacional e medida do úmero. Posteriormente, foi feita análise da correlação entre as medidas dos úmeros e a idade gestacional, sendo seus valores expressos em múltiplos da mediana (MoMs). O comprimento do úmero dos fetos com T21 foram confrontados com os fetos normais utilizando o teste t-Student. A medida do úmero foi avaliada considerando-se os níveis de corte abaixo do percentil 10, 5 e 2,5 a fim de obter as respectivas taxas de sensibilidade. Calculou-se, ainda, a razão de verossimilhança (RV). A seguir, foi utilizado um modelo linear geral tendo a idade materna como covariável para controlar na comparação. Comparou-se, também, a medida do comprimento do úmero dos fetos normais da população local com o comprimento do úmero esperado baseado na curva de Jeanty. Os testes foram realizados com nível de significância de 5%. Resultados: Foram incluídos 58 casos com T21 e 1888 controles normais. A sensibilidade do comprimento do úmero para a detecção da T21 utilizando o nível de corte abaixo do percentil 10 foi de 44,8 % com RV de 4,4, abaixo do percentil 5 foi de 34,4 % com RV de 6,9 e abaixo do percentil 2,5 foi de 31,0 % com RV de 12. O valor médio dos úmeros, em MoMs, de fetos com T21 é estatisticamente inferior ao dos fetos normais (p < 0,001), utilizando o teste t-Student. Quando controlada a idade materna na comparação entre os grupos, a diferença permaneceu estatisticamente significativa (p < 0,001). Fez-se uma análise para comparar o comprimento do úmero nos fetos normais da população local com o comprimento do úmero esperado para a curva de Jeanty, e viu-se que os fetos normais locais têm comprimento do úmero estatisticamente significante menor. Conclusões: Existe diferença estatisticamente significante entre o comprimento do úmero de fetos normais e de fetos com T21 na população local (p < 0,001). A sensibilidade para detecção de T21 foi de 44,8%, 34,4% e 31%, para o úmero abaixo do percentil 10, 5 e 2,5, respectivamente. A curva de Jeanty não tem rendimento adequado para uso como controle do crescimento umeral em fetos normais locais, acarretando com seu uso o inevitável aumento da taxa de falsos positivos de úmeros curtos
Título en inglés
Comparison of humeral length between fetuses with Down syndrome and normal fetuses
Palabras clave en inglés
Case-control studies
Down syndrome/ultrasonography
Humerus/embryology
Humerus/ultrasonography
Mass screening
Sensitivity and specificity
Ultrasonography prenatal
Resumen en inglés
Objective: This study aimed to compare the humeral length (HL) in fetuses with Down syndrome (T21) with HL in normal fetuses, by using instruments of reference of the local population. Method: A case-control study was conducted comparing HL in normal fetuses with HL in fetuses with T21, aged between 18 weeks and 23 weeks and 6 days. Fetuses with T21 who were examined between 1994 and 2012 were included. The normal controls were evaluated between 2007 and 2009. The averages, medians, and standard deviations were obtained for maternal age, gestational age, and HL. Afterwards, we analyzed the correlation between the HL and the gestational age, with values expressed as multiples of the median (MoMs). The HLs of fetuses with T21 were compared with the HLs in normal fetuses by using Student's t-test. The humeri were evaluated considering the cut-off levels below the 10th, 5th, and 2,5th percentiles to obtain the sensitivity. The likelihood ratios (LR) were also calculated. Next, a general linear model was used with maternal age as a covariate to control for comparison of the groups. Comparison was also made between the HL of fetuses in the local population and the expected HL, based on the Jeanty curve. The tests were performed with a significance level of 5%. Results: The study included 58 cases with T21 and 1888 normal controls. The sensitivity of the HL to detect T21 by using a cut-off level below the 10th percentile was 44.8% with a LR of 4.4; below the 5th percentile, the sensitivity was 34.4% with a LR of 6.9; and below the 2.5th percentile, the sensitivity was 31.0% with a LR of 12. The average value of the humerus, in MoMs, of fetuses with T21 is statistically lower than that of normal fetuses (p < 0.001), as measured by using Student's t-test. When maternal age was controlled as a covariant in the comparison between groups, the difference remained statistically significant (p < 0.001). An analysis to compare the HL in normal fetuses of the local population with expected HL based on the Jeanty curve concluded that the HL in normal fetuses of the local population is lower than expected. Conclusions: There is a statistically significant difference between the HL of normal fetuses and HL of fetuses with T21 in the local population (p < 0.001). The sensitivity for detection of T21 was 44.8%, 34.4%, and 31% for the humerus below the 10th, 5th and 2.5th percentile, respectively. The Jeanty curve is not adequate to use as growth control for humeri in local normal fetuses, as its use leads to an increase in false positive rates when measuring the proportion of short humeri
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2014-05-20
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.