• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.5.2006.tde-12092006-150413
Document
Auteur
Nom complet
Aline Girotto Ricci
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2006
Directeur
Jury
Brizot, Maria de Lourdes (Président)
Duarte, Geraldo
Takiuti, Nilton Hideto
Titre en portugais
"Estimativa ultra-sonográfica e clínica do peso fetal"
Mots-clés en portugais
Eficácia
Peso ao nascer
Peso fetal
Ultrasonografia pré-natal
Resumé en portugais
O objetivo deste estudo foi avaliar e comparar a eficácia da estimativa ultra-sonográfica e clínica na predição do peso fetal; analisar fatores maternos e fetais que poderiam interferir na estimativa ultra-sonográfica do peso fetal. Foram realizadas 212 avaliações, em até 24 horas do parto. Os fatores maternos avaliados foram peso, IMC e distância entre a pele e o útero; e os fetais constaram de apresentação, posição de dorso, localização e espessura placentárias, peso fetal e ILA. A estimativa ultra-sonográfica do peso fetal apresenta boa acurácia, já a clínica mostrou-se satisfatória na predição do peso no nascimento, embora com desempenho inferior à avaliação ultra-sonográfica. Quanto maior a distância entre a pele e o útero materno e quanto menor o peso fetal maior o erro na estimativa do peso
Titre en anglais
Ultrasound and clinical fetal weight estimation
Mots-clés en anglais
Birth weight
Efficacy
Fetal weight
Ultrasonography prenatal
Resumé en anglais
This study was designed to evaluate the accuracy of ultrasound and clinical fetal weight estimation; evaluate maternal and/or fetal factors that could interfere in ultrasound estimation of fetal weight and, compare the accuracy of ultrasound versus clinical fetal weight estimations. 212 estimation of fetal was performed within 24 hours to delivery. The maternal factors examined were: weight, BMI, skin to uterus distance, and as fetal factors: presentation, position, fetal weight, placental localization and thickness and AFI. Ultrasound presented good accuracy in the estimation of fetal weight. Thick distances between skin to uterus and small fetuses are associated to higher errors in estimating fetal weight. Clinical estimation of fetal weight was satisfactory in the prediction of birth weight, however with lower accuracy than ultrasound
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Alinegricci.pdf (6.81 Mbytes)
Date de Publication
2006-09-15
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.