• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.5.2006.tde-12092006-150413
Documento
Autor
Nombre completo
Aline Girotto Ricci
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2006
Director
Tribunal
Brizot, Maria de Lourdes (Presidente)
Duarte, Geraldo
Takiuti, Nilton Hideto
Título en portugués
"Estimativa ultra-sonográfica e clínica do peso fetal"
Palabras clave en portugués
Eficácia
Peso ao nascer
Peso fetal
Ultrasonografia pré-natal
Resumen en portugués
O objetivo deste estudo foi avaliar e comparar a eficácia da estimativa ultra-sonográfica e clínica na predição do peso fetal; analisar fatores maternos e fetais que poderiam interferir na estimativa ultra-sonográfica do peso fetal. Foram realizadas 212 avaliações, em até 24 horas do parto. Os fatores maternos avaliados foram peso, IMC e distância entre a pele e o útero; e os fetais constaram de apresentação, posição de dorso, localização e espessura placentárias, peso fetal e ILA. A estimativa ultra-sonográfica do peso fetal apresenta boa acurácia, já a clínica mostrou-se satisfatória na predição do peso no nascimento, embora com desempenho inferior à avaliação ultra-sonográfica. Quanto maior a distância entre a pele e o útero materno e quanto menor o peso fetal maior o erro na estimativa do peso
Título en inglés
Ultrasound and clinical fetal weight estimation
Palabras clave en inglés
Birth weight
Efficacy
Fetal weight
Ultrasonography prenatal
Resumen en inglés
This study was designed to evaluate the accuracy of ultrasound and clinical fetal weight estimation; evaluate maternal and/or fetal factors that could interfere in ultrasound estimation of fetal weight and, compare the accuracy of ultrasound versus clinical fetal weight estimations. 212 estimation of fetal was performed within 24 hours to delivery. The maternal factors examined were: weight, BMI, skin to uterus distance, and as fetal factors: presentation, position, fetal weight, placental localization and thickness and AFI. Ultrasound presented good accuracy in the estimation of fetal weight. Thick distances between skin to uterus and small fetuses are associated to higher errors in estimating fetal weight. Clinical estimation of fetal weight was satisfactory in the prediction of birth weight, however with lower accuracy than ultrasound
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Alinegricci.pdf (6.81 Mbytes)
Fecha de Publicación
2006-09-15
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.