• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.5.2018.tde-07112018-092737
Documento
Autor
Nombre completo
Juliana Valente Codato Marinelli
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2018
Director
Tribunal
Carvalho, Mário Henrique Burlacchini de (Presidente)
Britto, Ingrid Schwach Werneck
Brizot, Maria de Lourdes
Lobo, Guilherme Antonio Rago
Título en portugués
Parâmetros ultrassonográficos bi e tridimensionais em gestações únicas com colo uterino curto
Palabras clave en portugués
Artéria uterina
Colo do útero
Ecocardiografia Doppler
Ecocardiografia tridimensional
Segundo trimestre da gravidez
Ultrassonografia pré-natal
Resumen en portugués
INTRODUÇÃO: Pouco se sabe sobre parâmetros ultrassonográficos transvaginais possíveis de serem avaliados durante a gestação além do comprimento do colo uterino. A escassa literatura sugere que o volume calculado através da ultrassonografia tridimensional, a quantificação de sinal power Doppler em todo o órgão e o Doppler das artérias uterinas possam sofrer alterações de acordo com o comprimento cervical, e até mesmo anteceder seu encurtamento no processo que leva ao parto. OBJETIVOS: agregar novos parâmetros bi e tridimensionais ultrassonográficos à avaliação do colo uterino em gestações únicas. MÉTODO: Estudo transversal desenvolvido com dados de 2014 a janeiro de 2018 do projeto PROPE, no qual foi realizada ultrassonografia transvaginal em pacientes entre 20 e 23 semanas e 6 dias de gestação. Foram compilados e submetidos à análise secundária os dados de 162 gestantes com comprimento do colo uterino >= 25 mm (grupo Controle), 68 gestantes com comprimento do colo >= 15 mm e < 25 mm (grupo Colo Curto) e 18 gestantes com comprimento do colo < 15 mm (grupo Colo Muito Curto). Foram analisadas as características demográficas e antecedentes obstétricos das gestantes, e foram comparados entre os grupos os parâmetros cervicais de comprimento, volume e vascularização, além do Doppler de artérias uterinas bilateralmente. RESULTADOS: O comprimento médio (± DP) dos colos uterinos de cada grupo foi 35,28 ± 5,12 mm para o grupo Controle, 20,51 ± 2,47 mm para o grupo Colo Curto, e 10,72 ± 2,51 mm para o grupo Colo Muito Curto. Houve diferença entre os grupos quanto à idade materna, cor (etnia) e idade gestacional de inclusão. Quanto aos antecedentes obstétricos, houve associação somente entre a presença de colo curto na gestação atual e pelo menos um parto prematuro anterior em gestantes não nulíparas (p = 0,021). Em relação aos parâmetros ultrassonográficos, verificou-se correlação linear positiva moderada entre volume e comprimento do colo (coeficiente de Pearson=0.587, valor p < 0.0001). Os grupos Controle, Colo Curto e Colo Muito Curto foram estatisticamente diferentes em relação às médias (± DP) de volume (46,38 ± 13,60 cm vs. 32,15 ± 13,14 cm vs. 22,08 ± 11,10 cm, respectivamente)(p <= 0,001), e em relação às médias (± DP) de índice de fluxo (IF) (39,81 ± 6,42 cm vs. 38,73 ± 4,99 cm vs. 36,02 ± 5,34 cm, respectivamente) (p = 0,027), em que a diferença estatística ocorre entre os grupos Controle e Colo Muito Curto. Porém, na presença da informação do volume, após regressão linear, a associação entre os grupos e IF deixa de ser significativa. Também não houve relação entre os grupos estudados e o Doppler de artérias uterinas. CONCLUSÃO: Existe correlação linear positiva entre o volume e o comprimento do colo uterino. Na ausência de informações sobre o volume, comprimento cervical e índices de vascularização não se correlacionam. O comprimento cervical também não está relacionado a alterações no Doppler de artérias uterinas. Apesar das limitações de uma amostra pequena e escassez de dados comparativos na literatura, este estudo foi realizado com uma amostra homogênea da população e abre caminho para maiores pesquisas sobre o assunto
Título en inglés
Two and three-dimensional ultrasound parameters in single pregnancies with short cervix
Palabras clave en inglés
Cervix uteri
Echocardiography Doppler, Uterine artery
Echocardiography three-dimensional
Pregnancy trimester second
Ultrasonography prenatal
Resumen en inglés
INTRODUCTION: Little is known about transvaginal ultrasound parameters other than cervical length that can be assessed during gestation. The literature suggests that changes in volume on three-dimensional ultrasound, quantification of power Doppler signal in the entire organ, and Doppler sonography of uterine arteries may be related to cervical length, and even precede its shortening during spontaneous delivery. OBJECTIVES: To include new two- and three-dimensional ultrasonographic parameters for evaluation of the uterine cervix in single pregnancies. METHODS: A crosssectional study of data from Project PROPE on transvaginal ultrasonography performed in patients between 20 and 23 weeks and 6 days of gestation from May 2014 to January 2018 was conducted. Secondary analysis of data from 162 pregnant women with uterine cervical length >= 25 mm (Control group), 68 pregnant women with cervical length >= 15 mm and < 25 mm (Short Cervix group), and 18 pregnant women with cervical length < 15 mm (Very Short Cervix group) was performed. The demographic characteristics and obstetric history of the pregnant women were analyzed, and the cervical length, volume, and vascularization were compared between the groups. In addition, Doppler velocimetry of the uterine arteries was performed bilaterally. RESULTS: The mean cervical length (± SD) was 35.28 ± 5.12 mm for the Control group, 20.51 ± 2.47 mm for the Short Cervix group, and 10.72 ± 2, 51 mm for the Very Short Cervix group. The groups differed in maternal age, ethnicity, and gestational age. When analyzing the obstetric history of only non-nulliparous patients we observed a significant association between the presence of a short cervix in the current pregnancy and at least one previous preterm birth (p = 0.021). With regard to the ultrasonographic parameters, we observed a moderate positive linear correlation between the volume and length of the cervix (Pearson coefficient = 0.587, p < 0.0001). The Control, Short Cervix, and Very Short Cervix groups showed differences in the mean (± SD) volume (46.38 ± 13.60 cm vs. 32.15 ± 13.14 cm vs. 22.08 ± 11.10 cm, respectively) (p <= 0.001) and mean (± SD) flow index (FI) parameter of cervical vascularization (39.81 ± 6.42 cm vs. 38.73 ± 4.99 cm vs. 36.02 ± 5.34 cm, respectively) (p = 0.027), and the difference between the Control and Very Short Cervix groups was statistically significant. However, after linear regression, in the presence of volume information, we found no association between the groups and FI. CONCLUSION: Cervical length and volume are positively correlated. When information about the volume is not provided, there's no association between cervical length and vascularization. Uterine artery Doppler is not related to cervical length. Despite the limitations of a small sample size and less comparative data in the literature, this study was performed with a homogeneous sample population and paves the way toward further research on the subject
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2018-11-08
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.