Disertación de Maestría
DOI
https://doi.org/10.11606/D.5.2017.tde-07032017-143706
Documento
Autor
Nombre completo
Renata Wendel de Moraes
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2016
Director
Tribunal
Carvalho, Mário Henrique Burlacchini de (Presidente)
Britto, Ingrid Schwach Werneck
Brizot, Maria de Lourdes
Título en portugués
Validação de teste de reação em cadeia da polimerase fluorescente quantitativa (QF-PCR) para detecção de aneuploidias fetais
Palabras clave en portugués
Aberrações cromossômicas
Aneuploidia
Diagnóstico pré-natal
Fluorescência
Instabilidade cromossômica
Reação em cadeia da polimerase
Resumen en portugués
A reação em cadeia da polimerase fluorescente quantitativa (QF-PCR) é um método molecular de diagnóstico que se baseia na amplificação de pequenas sequências repetitivas do genoma (Short Tandem Repeats - STRs). Este método pode ser empregado para a detecção de aneuploidias durante a triagem pré-natal, porém, no Brasil, ainda não é utilizado nas instituições públicas. O objetivo do presente estudo foi avaliar a eficácia da QF-PCR em comparação com a citogenética na detecção de aneuploidias. Foram avaliadas 162 amostras de líquido amniótico de gestantes com risco fetal de aneuploidia aumentado. As amostras foram coletadas no Ambulatório de Obstetrícia do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo. O DNA fetal, para a análise do QF-PCR, foi extraído do líquido amniótico e foram utilizados 24 marcadores moleculares fluorescentes para a amplificação de genes presentes nos cromossomos 13, 18, 21, X e Y. A interpretação foi baseada na análise quantitativa dos fragmentos obtidos na amplificação. A análise citogenética foi realizada segundo metodologia convencional. A QF-PCR foi realizada às cegas, sem o conhecimento do resultado citogenético. A concordância entre os resultados obtidos pela citogenética e pela QF-PCR foi de 93,2% (151/162), com sensibilidade total de 90% e especificidade de 97,2%. Quando analisado apenas os resultados passíveis de detecção pela QF-PCR, sem os rearranjos, a concordância atinge 98,1% com sensibilidade de 98,7% e especificidade de 97,2%. O presente estudo demonstra que a QF-PCR é um método eficiente e confiável para triagem pré-natal de aneuploidias. Para a investigação de alterações cromossômicas estruturais a avaliação citogenética é necessária
Título en inglés
Validation of quantitative fluorescent polymerase chain reaction (QF-PCR) test to detect fetal aneuploidies
Palabras clave en inglés
Aneuploidy
Chomosomal instability
Chromosome aberrations
Fluorescence
Polymerase chain reaction
Prenatal diagnosis
Resumen en inglés
Quantitative fluorescence polymerase chain reaction (QF-PCR) is a molecular diagnostic method based on the amplification of short tandem repeats (STRs) present in genome. This method is widely used to detect aneuploidies in prenatal screening, but, in Brazil, it is not used in public services. We investigated the accuracy of QF-PCR for the prenatal recognition of common aneuploidies and compared these results with cytogenetic results in our laboratory. A total of 162 amniotic fluid samples of pregnancies with high risk of fetus aneuploid were collected at the Obstetric Ambulatory of Hospital das Clínicas - Universidade de São Paulo, São Paulo, Brazil. Fetal DNA was extracted and analyzed by multiplex QF-PCR kit, which contains 24 primer pairs located on chromosomes 13, 18, 21, X and Y. Cytogenetic analysis was performed based on conventional method. The results of cytogenetics test was not known while QF-PCR assay was performed. QF-PCR results were consistent with the results of cytogenetic analysis in 93.2% of all samples (151/162), with 90% total sensitivity and 97.2% specificity. When only possible results detected by QF-PCR are analyzed, without rearrangements samples, the agreement between both tests increases to 98.1%, with 98.7% sensitivity and 97.2% specificity. The present study demonstrates that QF-PCR was efficient and reliable for prenatal aneuploidy screening. This study suggests that QF-PCR can be used as a rapid diagnostic method; however, to structural chromosomal abnormalities cytogenetic analysis must be used
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2017-03-08
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.