• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.5.2017.tde-07032017-143706
Document
Author
Full name
Renata Wendel de Moraes
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2016
Supervisor
Committee
Carvalho, Mário Henrique Burlacchini de (President)
Britto, Ingrid Schwach Werneck
Brizot, Maria de Lourdes
Title in Portuguese
Validação de teste de reação em cadeia da polimerase fluorescente quantitativa (QF-PCR) para detecção de aneuploidias fetais
Keywords in Portuguese
Aberrações cromossômicas
Aneuploidia
Diagnóstico pré-natal
Fluorescência
Instabilidade cromossômica
Reação em cadeia da polimerase
Abstract in Portuguese
A reação em cadeia da polimerase fluorescente quantitativa (QF-PCR) é um método molecular de diagnóstico que se baseia na amplificação de pequenas sequências repetitivas do genoma (Short Tandem Repeats - STRs). Este método pode ser empregado para a detecção de aneuploidias durante a triagem pré-natal, porém, no Brasil, ainda não é utilizado nas instituições públicas. O objetivo do presente estudo foi avaliar a eficácia da QF-PCR em comparação com a citogenética na detecção de aneuploidias. Foram avaliadas 162 amostras de líquido amniótico de gestantes com risco fetal de aneuploidia aumentado. As amostras foram coletadas no Ambulatório de Obstetrícia do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo. O DNA fetal, para a análise do QF-PCR, foi extraído do líquido amniótico e foram utilizados 24 marcadores moleculares fluorescentes para a amplificação de genes presentes nos cromossomos 13, 18, 21, X e Y. A interpretação foi baseada na análise quantitativa dos fragmentos obtidos na amplificação. A análise citogenética foi realizada segundo metodologia convencional. A QF-PCR foi realizada às cegas, sem o conhecimento do resultado citogenético. A concordância entre os resultados obtidos pela citogenética e pela QF-PCR foi de 93,2% (151/162), com sensibilidade total de 90% e especificidade de 97,2%. Quando analisado apenas os resultados passíveis de detecção pela QF-PCR, sem os rearranjos, a concordância atinge 98,1% com sensibilidade de 98,7% e especificidade de 97,2%. O presente estudo demonstra que a QF-PCR é um método eficiente e confiável para triagem pré-natal de aneuploidias. Para a investigação de alterações cromossômicas estruturais a avaliação citogenética é necessária
Title in English
Validation of quantitative fluorescent polymerase chain reaction (QF-PCR) test to detect fetal aneuploidies
Keywords in English
Aneuploidy
Chomosomal instability
Chromosome aberrations
Fluorescence
Polymerase chain reaction
Prenatal diagnosis
Abstract in English
Quantitative fluorescence polymerase chain reaction (QF-PCR) is a molecular diagnostic method based on the amplification of short tandem repeats (STRs) present in genome. This method is widely used to detect aneuploidies in prenatal screening, but, in Brazil, it is not used in public services. We investigated the accuracy of QF-PCR for the prenatal recognition of common aneuploidies and compared these results with cytogenetic results in our laboratory. A total of 162 amniotic fluid samples of pregnancies with high risk of fetus aneuploid were collected at the Obstetric Ambulatory of Hospital das Clínicas - Universidade de São Paulo, São Paulo, Brazil. Fetal DNA was extracted and analyzed by multiplex QF-PCR kit, which contains 24 primer pairs located on chromosomes 13, 18, 21, X and Y. Cytogenetic analysis was performed based on conventional method. The results of cytogenetics test was not known while QF-PCR assay was performed. QF-PCR results were consistent with the results of cytogenetic analysis in 93.2% of all samples (151/162), with 90% total sensitivity and 97.2% specificity. When only possible results detected by QF-PCR are analyzed, without rearrangements samples, the agreement between both tests increases to 98.1%, with 98.7% sensitivity and 97.2% specificity. The present study demonstrates that QF-PCR was efficient and reliable for prenatal aneuploidy screening. This study suggests that QF-PCR can be used as a rapid diagnostic method; however, to structural chromosomal abnormalities cytogenetic analysis must be used
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2017-03-08
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.