• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Thèse de Doctorat
DOI
https://doi.org/10.11606/T.5.2016.tde-06092016-145622
Document
Auteur
Nom complet
Renata Moscolini Romão
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2016
Directeur
Jury
Carvalho, Mário Henrique Burlacchini de (Président)
Peralta, Cleisson Fábio Andrioli
Andrade, Lisandra Stein Bernardes Ciampi de
Brizot, Maria de Lourdes
Levi, José Eduardo
Titre en portugais
Desenvolvimento de um teste para a trissomia do cromossomo 21 através da análise de ácidos nucleicos fetais no plasma materno por sequenciamento de última geração
Mots-clés en portugais
Cromossomos humanos par 21
Diagnóstico pré-natal/métodos
DNA/sangue
Feto
Líquido amniótico
Plasma
Síndrome de Down
Resumé en portugais
O objetivo do presente trabalho foi o desenvolvimento de um teste não invasivo para a trissomia do cromossomo 21 através da análise de ácidos nucleicos fetais livres no plasma materno por sequenciamento de última geração realizado no sequenciador automático Ion Torrent. A metodologia proposta para o teste é a análise de SNPs com alta taxa de heterozigosidade na população brasileira localizados em dois genes presentes no cromossomo 21 (PLAC4 e C21orf105), e a detecção da cópia extra do cromossomo 21 é feita pela razão dos alelos desses SNPs, sendo que a razão de 1:1 indica que o feto é normal, e a razão de 2:1 indica que o feto tem uma cópia extra do cromossomo 21. Para a validação da metodologia foram utilizadas 50 amostras de DNA livre extraídas de líquido amniótico, previamente caracterizadas por análise citogenética consideradas como o padrão ouro pois contém apenas material genético fetal abundante. A metodologia foi validada com sucesso nessas amostras, sendo que as 24 amostras de fetos com trissomia foram claramente distinguidas das 26 amostras de fetos normais. A metodologia validada foi aplicada a 44 amostras de DNA livre extraídas de plasma de gestantes (21 amostras de fetos com trissomia do 21 e 23 de fetos normais), porém não foi possível fazer a distinção entre fetos normais e fetos com trissomia do 21, possivelmente devido à variações na fração fetal do DNA livre em relação à fração materna. Como nosso objetivo principal não foi alcançado, Propomos aqui que o teste realizado em líquido amniótico seja utilizado como uma alternativa mais simples, rápida e barata ao cariótipo convencional atualmente utilizado para fazer o diagnóstico da trissomia do cromossomo 21 em amostras coletadas por procedimentos invasivos, enquanto as deficiências do teste não-invasivo pelo plasma materno são aprimoradas
Titre en anglais
Development of a trisomy 21 test by analysis of fetal nucleic acids in maternal plasma by next-generation sequencing
Mots-clés en anglais
Amniotic fluid
Chromosomes human pair 21
DNA/blood
Down syndrome
Fetus
Plasma
Prenatal diagnosis
Resumé en anglais
The purpose of this study was to develop a test for trisomy 21 by analyzing cell-free fetal nucleic acids in maternal plasma by next-generation sequencing performed on automated sequencer Ion Torrent. The proposed methodology for the test is based on analysis of SNPs with high heterozygosity rates in Brazilian population, located in two genes present on chromosome 21 (PLAC4 and C21orf105), and the detection of the extra copy of chromosome 21 is made by the allelic-ratio of these SNPs, where 1:1 ratio indicates a normal fetus, and the 2:1 ratio indicates that the fetus has an extra copy of chromosome 21. In order to validate the methodology 50 cell-free DNAs extracted from amniotic fluid were used representing a gold standard since it contains abundant genetic material exclusively from the fetus. The methodology has been successfully validated in these samples, all the 24 samples from fetuses with trisomy 21 were clearly distinguished from 26 samples of normal fetuses. The validated method was applied to 44 cell-free DNA samples extracted from plasma of pregnant women (21 samples from fetuses with trisomy 21 and 23 from normal fetuses), but unfortunately it was not possible to distinguish between normal and trisomy 21 fetuses, possibly due to variations on the fetal fraction of the cell-free DNA in relation to maternal fraction. As our main goal was not achieved, we propose here that the test performed on amniotic fluid sample could be used as a simpler, faster and cheaper alternative test to traditional karyotype, which is used nowadays to make the diagnosis of trisomy 21 in samples collected by invasive procedures. In parallel, minor improvements in the described method may enable its clinical use
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2016-09-08
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.