• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Doctoral Thesis
DOI
https://doi.org/10.11606/T.5.2016.tde-23022016-160047
Document
Author
Full name
Wagner Malagó Tavares
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2015
Supervisor
Committee
Fonoff, Erich Talamoni (President)
Contreras, Lionel Fernel Gamarra
Fernandes, Adriano Yacubian
Martins, Roberto Sergio
Miura, Flávio Key
Title in Portuguese
Avaliação de protocolo para redução da distorção em estereotaxia para ressonância magnética de três tesla
Keywords in Portuguese
Algoritmos
Imagens de fantasmas
Neurocirurgia
Processamento de imagem assistida por computador
Radiocirurgia
Abstract in Portuguese
Introdução: o presente estudo demonstra a aplicação de um algoritmo para correção de distorções em imagens de RM em 3T. Métodos: foi utilizado um Modelo Tridimensional com Alvos (MTA) de acrílico (Micromar, São Paulo, Brasil) montado em uma plataforma com as dimensões e características de um arco estereotáctico. O MTA foi submetido à aquisição de imagens em uma bobina de crânio utilizando o aparelho Philips 3T Magnetom Sigma LX(TM) (Philips Medical Systems, Eindhoven, Netherlands). Para cada aquisição duas imagens foram obtidas, a normal e a reversa (nRM e rRM, respectivamente). Foi aplicado o protocolo de correção com gradiente reverso para produzir coordenadas x, y e z corrigidas. Após ter sido determinada a acurácia dos alvos, foram submetidos 20 pacientes ao mesmo protocolo para determinar a validade em indivíduos. Resultados: a análise dos dados demonstrou que as diferenças entre observadores não foram estatisticamente significantes. Além disso, os pontos obtidos após o processo de retificação das coordenadas no MTA revelou uma distorção média de 1,05 mm. Nos pacientes, a distorção pré correção variava de 0 a 5,6 mm; após a correção variou entre 0 e 3,5 mm. Conclusão: o presente estudo examinou uma técnica de retificação das distorções geométricas encontradas em imagens de RM. Esta mostrou-se bem sucedida em produzir resultados consistentemente acurados para registro de alvos estereotácticos. A técnica pode ser aplicada de maneira universal a todas as imagens de RM adquiridas em protocolo spin-echo e corrige as distorções geométricas presentes
Title in English
A method for geometric distortion correction for stereotaxic neurosurgery on three tesla
Keywords in English
Algorithms
Image processing computer-assisted, Phantoms imaging
Neurosurgery
Radiosurgery
Abstract in English
The present work presents an application of a image distortion correction algorithm for 3T MR images. Methods: We used a phantom head model (Micromar, São Paulo, Brazil) mounted on a plataform with the dimensions and features of a stereotactic frame. The phantom was scanned within the head coil of a Philips 3T Magnetom Sigma LX(TM) (Philips Medical Systems, Eindhoven, Netherlands). For each scan, 2 images were obtained - the normal and the reversed image (nMR and rMR, respectively). We applied the inverted gradient correction protocol to produce a corrected x, y and z coordinate. After we ensure target accuracy we submitted 20 patients to the same protocol to exactitude evaluation in human subjects. Results: For all the analyzed data, the differences among the observers were not statistically significant. Moreover, the data rectification proved to be effective as the average distortion on phantom, after correction, was 1.05 mm. On patients the pre-correction distortion varied between 0 and 5.6mm, after correction it varied between 0 mm and 3.5 mm. Conclusion: This study examined a rectifying technique for correcting geometric distortions encountered in the MR images, and the technique proved to be highly successful in producing consistently accurate stereotactic target registration. The technique is universally applicable to all routinely employed spin-echo MR images, and corrects for geometric distortions
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2016-02-25
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.