• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Doctoral Thesis
DOI
https://doi.org/10.11606/T.5.2015.tde-12082015-160504
Document
Author
Full name
Christian Diniz Ferreira
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2015
Supervisor
Committee
Matushita, Hamilton (President)
Nishikuni, Koshiro
Pinto, Fernando Campos Gomes
Salomão, José Francisco Manganelli
Shu, Edson Bor-Seng
Title in Portuguese
Modelo anatômico de ventriculomegalia para treinamento neuroendoscópico
Keywords in Portuguese
Cadáver
Educação médica
Encéfalo
Hidrocefalia
Médicos residentes
Modelos anatômicos
Neuroendoscopia
Terceiro ventrículo/cirurgia.
Abstract in Portuguese
OBJETIVO: Desenvolver peças anatômicas que simulem uma condição real de ventriculomegalia para serem utilizadas como uma ferramenta no treinamento dos neurocirurgiões nas técnicas de neuroendoscopia e viabilizar estudo anatômico dos ventrículos. MÉTODO: Foram utilizadas vinte peças anatômicas de encéfalo de cadáveres de indigentes, com a aprovação do Comitê de Ética em pesquisa da FMUSP sob o número 046/10. As peças foram retiradas da base do crânio com a persistência da superfície óssea (parte da calvária) para serem submetidas aos seguintes procedimentos: canulação do IV ventrículo por meio da abertura mediana do IV ventrículo (forame de Magendie); tomografias pré-experimento e injeção de água destilada no sistema ventricular. A água injetada estava à temperatura ambiente e os cérebros foram resfriados até 4º C e, após 12 horas, foram congelados a uma temperatura de 0º C (no estado sólido) por 24 horas. Esses procedimentos foram realizados na frequência de três vezes. Após o experimento, foram realizadas tomografias pós-experimento e procedimentos neuroendoscópicos ventriculares. Foram excluídos encéfalos com lesões traumáticas ou antecedentes de enfermidades transmissíveis. Não foram critérios de exclusão o sexo e a idade. Foram avaliadas, nas imagens tomográficas, a variação pré e pós-experimento dos seguintes parâmetros: coeficiente corno frontal/diâmetro interno; índice de Evan; e tamanho do corno temporal. As análises estatísticas foram realizadas no programa SPSS (Statistical Package for the Social Sciences) versão 13, para ambos os grupos. RESULTADOS: A avaliação da relação Corno frontal/Diâmetro interno, antes e pós-experimento apresentou média de 11,98% e 19,46%, respectivamente. Estudo estatístico (t Student) mostrou diferença estatística (t= -5142, gl =19; p < 0,01). O Índice de Evan também apresentou diferença significativa (t = -5,172, gl = 9; p < 0,01) entre os resultados antes (média de 10,86%) e após experimento (média de 18,35%). A análise do tamanho do corno temporal mostrou diferença significativa entre os grupos antes e depois do experimento (t = -2,297, gl = 9; p< 0,01), indicando que o tamanho mediano do Corno Temporal é maior após o experimento (média de 2,65cm). CONCLUSÕES: A exploração das características físico-químicas anômalas da molécula da água pode nos fornecer um bom mecanismo expansor de cavidades ventriculares para a indução de ventriculomegalia em uma peça anatômica de encéfalo, em que o endoscópio poderá ser introduzido pelas vias habituais, podendo, assim, realizar observação anatômica e simular o procedimento cirúrgico com a mesma sensibilidade tátil que irá encontrar no procedimento real
Title in English
Ventriculomegaly anatomical models for neuroendoscopy training
Keywords in English
Anatomical models
Cadaver
Encephalus
Hydrocephalus
Medical education
Neuroendoscopy
Residents medical
Third ventricle/surgery
Abstract in English
PURPOSE: To develop anatomical models which simulate real conditions of ventriculomegaly and to use them as tools to train neuroendoscopic techniques and allow the study of the ventricles. METHODS: A total of twenty brains, with the approval of the Ethics in Research Committee from FMUSP (046/10) were used to perform this research. The brains were separated from the skull base, but keeping part of the calvaria, and then underwent the following procedures: cannulation of the fourth ventricle through the median open of the fourth ventricle (foramen of Magendie); CT scans performed before the experiment; and then injection of distilled water into the ventricular system. The water was injected at room temperature, and then the brains were cooled to 4ºC. After 12 hours, they were then frozen at 0ºC for 24 hours.These procedures were repeated three times. After the experiment,CT scans were performed after the injections and neuroendoscopic procedures. Brains, which had traumatic injuries or history of infectious diseases, were excluded. Gender and age were not exclusion criteria. The statistical analysis was performed with the SPSS program (Statistical Package for the Social Sciences) version 13, for both groups. To assess the variation of the frontal horn (FH)/internal diameter (ID) coefficient, such as Evan's index's variation, and to analyze the temporal horn (TH) size, thet-Student test was used. RESULTS: The results of the t-Student test showed that the FH/ID, with an average of 11.98% before the experiment, had significant difference (t = -5.142, gl = 19; p < 0.01) after the experiment, with an average of19.46%. The Evan's index also showed a significant difference (t = -5.172, gl = 9; p < 0,01) with an initial average of 10.86% and a final average of 18.35%. The analysis of the temporal horn size showed a significant difference between the size before and after the experiment (t = -2.297, gl = 9; p < 0.01), indicating the significant increase of the temporal horn (with an initial average of 0.02cm and a final average of 2.65cm). CONCLUSIONS: The use of the anomalous physical and chemical characteristics of water can provide us with a good expanding mechanism of the ventricular system, creating ventriculomegaly in anatomical models, allowing the endoscope to be introduced by the usual approaches, to perform anatomical observation, and to simulate a surgical procedure with the same sensitivity of a real procedure
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2015-08-12
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.