• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.5.2010.tde-23112010-174300
Document
Author
Full name
Célia Luiza de Lima Rodrigues
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2010
Supervisor
Committee
Levi, José Eduardo (President)
Fonseca, Benedito Antonio Lopes da
Okay, Thelma Suely
Title in Portuguese
Avaliação da coleta de sangue em papel de filtro para diagnóstico molecular da dengue
Keywords in Portuguese
Coleta de amostras sanguíneas
Corantes fluorescentes
Dengue/diagnóstico
Reação em cadeia da polimerase
Abstract in Portuguese
O diagnóstico rotineiro da dengue é realizado com amostra de sangue dos casos suspeitos. A coleta tradicional de sangue (por punção venosa) é um procedimento que dificulta a realização de exames e pesquisas por ser um procedimento invasivo que nem sempre é prático para crianças e bebês, requer pessoal especializado e necessita de um local para armazenamento da amostra sob refrigeração ou congelamento. O propósito deste estudo foi coletar amostras por punção digital com uma nova tecnologia (FTA Card) e compará-la com amostras coletadas por punção venosa, avaliando-as através de uma técnica molecular de PCR em tempo real. Sendo o PCR em Tempo Real a técnica molecular atualmente disponível de maior rapidez, sensibilidade e especificidade, padronizamos uma metodologia de passo único de PCR em Tempo Real com SYBR green baseando-se na região 3 não codificante do vírus e utilizando primers degenerados, capazes de detectar os quatro sorotipos de uma só vez. A avaliação das técnicas de coleta e amplificação foram feitas com amostras suspeitas de dengue, obtidas em Goiânia durante surto ocorrido no ano de 2008. O limite de detecção da reação padronizada no presente estudo foi de aproximadamente 100 cópias/ml e uma especificidade de 100%. Para tipagem das amostras positivas a técnica empregada foi o PCR multipex. Dentre as 89 amostras coletadas 60 (67%) foram positivas para àquelas coletadas por punção venosa e 14 (16%) para àquelas coletadas por punção digital. Dentre as 89 amostras para o PCR em Tempo Real, apenas 29 (32%), foram tipadas pelo método de PCR multiplex, sendo 3 casos do vírus da dengue 1 (10%), 16 casos do vírus da dengue 2 (55%), e 10 casos do vírus da dengue 3 (35%). Descritores: Dengue/diagnóstico, coleta de amostras sanguíneas, reação em cadeia da polimerase, corantes fluorescentes
Title in English
Evaluation of blood collected in fta cards for the detection of dengue virus RNA
Keywords in English
Blood specimen collection
Dengue/diagnosis
Fluorescent dyes
Polymerase chain reaction
Abstract in English
The collection by venipuncture is a procedure that is difficult to carry out in diagnosis and research because it is an invasive procedure that is not always practical for children and babies , requires specialized staff, needs a place to store the sample under refrigeration or forzen, This study aimed to collect samples by fingerstick puncture with a new technology named FTA card and compare it with samples collected by venipuncture, using a realtime PCR to evaluate if FTA card collection would have a similar performance to standard blood sampling. Towards that, we obtained viral load values in order to estimate the differences not only qualitatively (e.g. pos or neg) but also in numbers.. We used an one-step SYBR Green I Real-Time PCR based on the region 3 'noncoding virus using degenerate primers which was able to detected all four serotypes of dengue virus. Among the 89 samples collected 60 (67%) were positive for those collected by venipuncture and 14 (16%) to those collected by fingerstick, Only 29 (32%) were possible to be typed by PCR multiplex. Three cases were dengue virus 1 (10%), 16 cases were dengue virus 2 (55%) and 10 cases were dengue virus 3 (35%). The limit of detection obtained was approximately 100 copies / ml and aspecificity of 100% was observed. Keywords: Dengue / diagnosis, collection of blood samples, polymerase chain reaction, fluorescent dyes
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2010-11-26
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.