Doctoral Thesis
DOI
https://doi.org/10.11606/T.5.2019.tde-15012019-100022
Document
Author
Full name
Vitor Cervantes Gornati
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2018
Supervisor
Committee
Silva, Erasmo Simao da (President)
Ayres, Inêz Ohashi Torres
Sincos, Igor Rafael
Zerati, Antonio Eduardo
Title in Portuguese
Desenvolvimento e aplicação prática de shunt vascular temporário por punção: estudo experimental em porcos
Keywords in Portuguese
Dispositivos de acesso vascular
Lesões do sistema vascular
Procedimentos cirúrgicos vasculares
Shunt vascular
Shunt vascular temporário
Trauma de extremidades
Trauma vascular
Abstract in Portuguese
Os shunts vasculares temporários (SVT) são utilizados como uma técnica eficaz para reestabelecer rapidamente o fluxo sanguíneo em casos de lesão vascular com isquemia do membro ou órgão acometido, no qual a revascularização deverá ser postergada. Habitualmente, o SVT é inserido dentro dos cotos proximal e distal do vaso lesado através de uma abertura na pele, visando restaurar a perfusão e interromper a isquemia. O objetivo deste estudo é comparar a pressão arterial média (PAM em mmHg) e o fluxo sanguíneo (em ml/min) em dois modelos de SVT, um habitual e outro implantado por punção, bem como o tempo para a inserção destes dispositivos e suas patências primária e secundária. Realizamos experimentos em 30 suínos, somando 60 intervenções de revascularização arterial temporária dos membros posteriores: trinta SVT habituais e trinta por punção. Analisamos a PAM durante os procedimentos nos membros posteriores e o fluxo através dos dois tipos de SVT. A análise de fluxo mostrou uma diferença significativa entre os SVT testados (p=0,001), sendo menor no grupo SVT por punção. No entanto, o tempo decorrido (min) para inserção do SVT habitual foi maior do que o tempo para inserção do SVT por punção (15,32 ± 3,08 vs. 10,37 ± 1,7, p=0,001). Além disso, observamos uma recuperação da PAM nos membros submetidos aos dois tipos de SVT próxima à PAM sistêmica em 100% dos experimentos. Os resultados revelaram patência primária, secundária, e taxa de complicações similares entre os dois tipos de SVT. Concluímos que o fluxo foi menor no SVT por punção, mas a recuperação da PAM foi semelhante e com menor tempo de inserção do SVT por punção
Title in English
Development and practical application of a puncture temporary vascular shunt: an experimental study in pigs
Keywords in English
Temporary vascular shunt
Vascular access devices
Vascular shunt
Vascular surgical procedures
vascular system injury
Vascular trauma, Extremity trauma
Abstract in English
Temporary vascular shunts (TVS) are used as an effective technique to rapidly restore blood flow in cases of vascular injury with ischemia of the affected limb or organ, in which revascularization shall be postponed. Usually, TVS is positioned within the proximal and distal stumps of the injured vessel, through an opening of the skin, in order to restore perfusion and stop the ischemia. We sought to compare mean blood pressure (MBP in mmHg) and blood flow (ml/min) between two types of TVS, a standard one and a puncture one, as well as the time spent to insert these devices. We performed an experimental study on 30 pigs, including 60 vascular interventions in posterior limbs: thirty standard TVS and thirty puncture TVS. MBP was analyzed during the interventions in both posterior limbs and the flow through both types of TVS. Flow analysis revealed a significant difference between the two types of TVS (p=0,001), being lower in the puncture TVS. However, the time spent during standard TVS insertion was greater than that of the puncture shunt (15,32 ± 3,08 min vs.10,37 ± 1,7 min, p=0,001). In addition, we observed a limb MBP recovery close to systemic MBP in 100% of the experiments. The results show similar primary and secondary patency and complication rate in both TVS types. Therefore, we conclude that the flow was lower in the puncture TVS, but the MBP recovery was similar and it took less time to be inserted
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2019-01-16
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.