• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Doctoral Thesis
DOI
https://doi.org/10.11606/T.5.2014.tde-14012015-145945
Document
Author
Full name
Pablo Rodrigo de Siqueira
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2014
Supervisor
Committee
Poggetti, Renato Sergio (President)
Fontes, Belchor
Hashiba, Kiyoshi
Malheiros, Carlos Alberto
Sakai, Paulo
Title in Portuguese
Sutura endoscópica para perfuração gástrica nos procedimentos cirúrgicos endoscópicos translumenais por orifício natural, utilizando dispositivo T-Tag associado à câmara plástica protetora: factibilidade e resultados - estudo experimental
Keywords in Portuguese
Cirurgia endoscópica por orifício natural
Endoscopia do sistema digestório
Estômago/lesões
Modelos animais
Procedimentos cirúrgicos do sistema digestório
Técnicas de sutura
Abstract in Portuguese
A perfuração gástrica por endoscopia é a consequência de alguns de seus procedimentos, e atualmente, com o advento das cirurgias endoscópicas translumenais por orifícios naturais, um meio de manipulação dos órgãos abdominais. Esse é o motivo pelo qual os endoscopistas estão procurando um reparo endoscópico seguro. O objetivo foi avaliar a factibilidade e os resultados do fechamento da abertura gástrica similar àquelas realizadas nos procedimentos cirúrgicos endoscópicos translumenais por orifícios naturais utilizando-se o T-Tag associado à câmara plástica protetora. Sob anestesia geral, dez porcos Landrace foram submetidos a uma perfuração gástrica calibrada em 18 mm de diâmetro. A abertura foi fechada pelo novo método apresentado, composto de fios cirúrgicos conectados em uma âncora metálica (T-Tag) posicionados pela parede gástrica através de uma agulha. Uma câmara protetora plástica foi adaptada à extremidade distal do endoscópio para proteger os órgãos abdominais adjacentes da punção da agulha fora do estômago. Seis dispositivos T-Tag foram posicionados na maioria dos casos e os fios atados com um apertador de nó metálico endoscópico formando três pontos de sutura. O teste de vazamento foi realizado com uma pinça endoscópica e distensão da câmara gástrica com ar. Os animais receberam líquidos no mesmo dia do procedimento. Uma dose de antibiótico diária por dois dias foi administrada. Nenhuma complicação foi detectada no período pós-operatório. Um mês depois, a endoscopia revelou a presença de cicatriz em todos os animais, e a maioria apresentava materiais da sutura aderidos à superfície mucosa da região. A região do antro gástrico apresentava poucas aderências identificadas na laparotomia realizada no mesmo momento. O reparo endoscópico utilizando o T-Tag e a câmara protetora plástica é factível, fácil de ser realizada e seguro. São necessários estudos adicionais para mostrar o real valor desse tipo de procedimento
Title in English
Endoscopic suturing for gastric perforation in natural orifice translumenal endoscopic surgery procedures, using T-Tag device and a plastic protection chamber: feasibility and results- experimental study
Keywords in English
Digestive system surgical procedures
Endoscopy digestive system
Models animal
Natural orifice endoscopic surgery
Stomach/injuries
Suture techniques
Abstract in English
The endoscopic gastric perforation is a consequence of some endoscopic procedures and now a way to manage abdominal organs. This is the reason why endoscopists are studying a safe endoscopic repair. The objective was to evaluate feasibility and results of the gastric opening closure similar to those performed in natural orifice translumenal endoscopic surgery procedures using T-Tag associated with the plastic protection chamber. Ten Landrace pigs underwent a gastric perforation of 1.8 cm in diameter under general anesthesia. The opening was repaired with stitch assembled in a T-Tag anchor placed through the gastric wall with a needle. A plastic transparent chamber, adapted to the endoscope tip protected the abdominal organs from the needle puncture outside the stomach. Six T-Tags were placed in most cases and the stitches were tied with a metallic tie-knot, forming three sutures. The leakage test was performed with a forceps and by air distention. The animals received liquids in the same operative day. One daily shot antibiotic during two days was used. No complication was detected in the postoperative course. One month later the endoscopy revealed a scar in all animals, and the majority of these with suture material. The antral anterior gastric wall was clear with few adhesions in the laparotomy performed in the same time. The endoscopic repair using T-Tag and a protector chamber is feasible, easy to perform and safe. Further studies are needed to show the real value of this kind of procedure
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2015-01-14
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.