• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Doctoral Thesis
DOI
https://doi.org/10.11606/T.5.2011.tde-30112011-184542
Document
Author
Full name
Rodrigo Tavares Silva
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2011
Supervisor
Committee
Martinelli Filho, Martino (President)
Costa, Roberto
Luiz, Fatima Dumas Cintra
Medeiros, Paulo de Tarso Jorge
Oliveira, Júlio César de
Title in Portuguese
Avaliação dos eventos arrítmicos em candidatos a transplante renal pela monitorização cardíaca com looper implantável
Keywords in Portuguese
Arritmias cardíacas/diagnóstico
Diálise
Eletrocardiografia ambulatorial/instrumentação
Morte súbita cardíaca
Transplante de rim
Abstract in Portuguese
INTRODUÇÃO: pacientes com doença renal crônica em diálise apresentam elevada mortalidade anual, principalmente decorrente de eventos cardiovasculares, com destaque para morte súbita cardíaca (MSC). Os eventos arrítmicos (EA) são considerados os principais responsáveis pela MSC, tornando relevante a sua avaliação. Dispositivos cardíacos modernos como o looper implantável, que tem capacidade de monitorar o ritmo cardíaco por longo período de tempo e diagnosticar EA, podem contribuir na estratificação de risco desta população. OBJETIVOS: avaliar a taxa de ocorrência dos EA em candidatos a transplante renal com looper implantável e identificar fatores associados; determinar a significância prognóstica dos EA na MSC e mortalidade total; avaliar eficiência diagnóstica do looper e o papel da diálise. MÉTODOS: estudo clínico observacional, prospectivo e aberto que incluiu cem candidatos a transplante renal, em hemodiálise e com alto risco para transplante (idade >=50 anos, DM ou doença cardiovascular). Entre junho/2009 e janeiro/2010, os pacientes foram submetidos ao implante do looper para detecção dos EA e seguimento clínico de um ano. A idade média do grupo foi 59 anos; 65% homens; 97% hipertensos, 70% diabéticos, 34% com infarto prévio e tempo médio de 53,8 meses em hemodiálise. O diagnóstico dos EA seguiu protocolo específico e foram descritos todos os eventos clínicos fatais e não fatais. A estatística incluiu: análise descritiva dos EA, associação destes com variáveis exploratórias pelos testes de qui-quadrado, exato de Fischer, t-Student, Mann-Whitney e regressão logística stepwise selection para análise multivariada (p<0,05). RESULTADOS: foram diagnosticados 5075 EA em 98 pacientes em seguimento médio de 425 dias. A taxa de ocorrência dos EA na casuística foi: bradiarritmias (25%), arritmias supraventriculares (94%) e arritmias ventriculares (79%). Os EA mais comuns foram: taquicardia sinusal (39%) e atrial não sustentada (27%), extrassístoles ventriculares e atriais isoladas (16% e 5,4%) e taquicardia ventricular não sustentada (TVNS - 5,3%). Foram preditores para ocorrência dos EA: duração intervalo PR (p=0,0008; OR=1,05; IC-95%=1,02-1,08) e QT longo (p=0,002; OR=7,28; IC- 95%=2,01-26,35) para bradiarritmias; duração intervalo QTc (p=0,022; OR=1,02; IC-95%=1,01-1,04) e presença de insuficiência cardíaca (p=0,034; OR=9,87; IC- 95%=1,17-82,79) para arritmias ventriculares e dilatação ventricular esquerda (p=0,041; OR=2,83; IC-95%=1,01-7,96) para TVNS. Ocorreram 35 eventos clínicos não fatais, 14 transplantes renais e 18 óbitos. Dentre os óbitos, 38,9% foram cardiovasculares súbitos: quatro arritmogênicos, um IAM e dois indeterminados. Não houve associação entre EA e eventos fatais; fibrilação atrial e bradiarritmias tiveram associação significativa com eventos não fatais. O mecanismo de morte (arritmogênico) foi elucidado pelo looper em quatro pacientes com MSC; um paciente apresentou bloqueio atrioventricular e necessitou de marca-passo. A taxa de EA foi superior no período intradiálise em comparação ao interdiálise (p<0,001). CONCLUSÕES: neste estudo, que avaliou a monitorização cardíaca prolongada com looper implantável em candidatos a transplante renal, a taxa de ocorrência de EA foi elevada; foram preditores dos EA: a duração intervalo PR e presença de QT longo para bradiarritmias, duração intervalo QTc e insuficiência cardíaca para arritmias ventriculares e dilatação ventricular para TVNS; a taxa de mortalidade foi elevada, com importante contribuição da MSC; não houve associação entre EA e mortalidade total ou súbita; houve associação entre as bradiarritmias e a fibrilação atrial com a ocorrência de eventos não fatais; os EA foram mais frequentes no período intradiálise; o looper implantável foi eficiente na elucidação diagnóstica, com poucas complicações.
Title in English
Long-term recording of arrhythmic events with implantable cardiac monitor in renal transplant candidates
Keywords in English
Ambulatory electrocardiograhy/instrumentation
Cardiac arrhythmias/diagnosis
Dialysis
Kidney transplantation
Sudden cardiac death
Abstract in English
INTRODUCTION: chronic kidney disease patients undergoing dialysis have a high annual mortality rate, mainly due to cardiovascular disease. Sudden cardiac death (SCD), attributed to arrhythmic mechanisms, is considered the major cause of these high death rates. The implantable loop recorder (ILR), a modern cardiac device has the ability for long-term cardiac rhythm monitoring and diagnosing arrhythmic events (AE), which in fact may contribute to the risk stratification of this population. OBJECTIVES: this study was designed to evaluate the incidence and predictors of AE in renal transplant candidates with ILR; to determine the prognostic significance of AE in SCD and all-cause mortality, evaluate the diagnostic effectiveness of ILR and the role of dialysis. METHODS: a prospective, open, observational clinical study was conducted, including one hundred renal transplant candidates undergoing hemodialysis, at high risk for transplantation (age >=50 years, diabetes or cardiovascular disease). Between June/2009 and January/2010, patients received an ILR for detection of AE with a one-year follow-up. Mean age of the group was 59 years; 65% were men; 97% hypertensive, 70% diabetic, 34% had previous myocardial infarction and mean hemodialysis time was 53.8 months. The diagnosis of AE followed specific protocol and all fatal and non-fatal clinical events were described. The statistical analysis included: descriptive analysis of AE, an association between these events and exploratory variables by chi-square tests, Fisher exact test, Student's t test, Mann-Whitney test and logistic regression using stepwise selection for multivariate analysis (p<0.05). RESULTS: during mean follow-up of 425 days, 5075 AE were diagnosed by ILR in 98 patients. The rate of occurrence of EA in this patients was: bradyarrhythmias (25%), supraventricular arrhythmias (94%) and ventricular arrhythmias (79%). The most common AE were: sinus tachycardia (39%), nonsustained atrial tachycardia (27%), isolated premature ventricular beats (16%), isolated premature atrial beats (5.4%) and nonsustained ventricular tachycardia (NSVT - 5.3%). Predictors for the occurrence of AE were: duration of PR interval (p=0.0008; OR=1.05; 95%CI=1.02-1.08) and long QT (p=0.002; OR=7.28; 95%CI=2.01-26.35) for bradyarrhythmia; duration of QTc interval (p=0.022; OR=1.02; 95%CI=1.01-1.04) and presence of heart failure (p=0.034; OR=9.87; 95%CI=1.17-82.79) for ventricular arrhythmia and left ventricular dilatation (p=0.041; OR=2.83; 95%CI=1.01-7.96) for NSVT. There were 35 non-fatal clinical events, 14 renal transplantations and 18 deaths during follow-up. Regarding causes of death, 38.9% were due to sudden cardiovascular event: four were arrhythmogenic, one resulted from acute myocardial infarction and two were indeterminate. There was no association between AE and all cause or sudden mortality; bradyarrhythmias and atrial fibrillation were associated with the occurrence of non-fatal clinical events. The mechanism of death (arrhythmogenic) was elucidated by ILR in four patients with SCD; one patient had atrioventricular block and required pacemaker insertion. The rate of AE was higher in the intradyalitic period compared to interdialytic (p <0.001). CONCLUSIONS: in this study, which evaluate long-term cardiac rhythm monitoring with ILR in renal transplant candidates, the incidence of AE was high; predictors for the occurrence of AE were: duration of PR interval and presence of long QT for bradyarrhythmia, duration of QTc interval and heart failure for ventricular arrhythmia and left ventricular dilatation for NSVT; mortality rate was high and SCD made an important contribution. There was no association between AE and all-cause mortality and SCD; bradyarrhythmias and atrial fibrillation were associated with non-fatal events; the EA rate was higher at intradialytic period; the ILR was efficient in elucidating diagnoses and had few complications.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2011-12-01
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.