• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Thèse de Doctorat
DOI
https://doi.org/10.11606/T.5.2005.tde-20102005-150207
Document
Auteur
Nom complet
Sissy Lara Melo
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2005
Directeur
Jury
Sosa, Eduardo Argentino (Président)
Coelho, Otavio Rizzi
Negrao, Carlos Eduardo
Pimenta, João
Zimerman, Leandro Ioschpe
Titre en portugais
Ablação do istmo cavo-tricuspídeo para controle do flutter atrial: estudo prospectivo e randomizado comparando eficácia e segurança de cateter irrigado com cateter de 8 mm.
Mots-clés en portugais
Ablação por cateter/métodos
Ensaios controlados Aleatórios
Estudos prospectivos
Flutter atrial/terapia
Resumé en portugais
O cateter irrigado foi comparado com o de 8 mm para ablação com radiofrequência do istmo cavo-tricuspídeo(Ist-CT). Foram randomizados 52 pacientes portadores de flutter atrial típico para ablação com cateter irrigado(grupoI) ou com cateter de 8 mm(grupo II). O bloqueio do Ist-CT foi obtido em 51 pacientes. Não houve diferença estatística em relação aos parâmetros de aplicação de RF entre os dois grupos. A ablação do Ist-CT com cateter irrigado versus cateter de 8mm foi igualmente eficaz e segura no controle do flutter atrial típico.
Titre en anglais
Cavotricuspid isthmus ablation for the treatment of atrial flutter: prospective randomized study comparing efficacy and safety of cooled-tip versus 8-mm-tip catheters.
Mots-clés en anglais
Atrial flutter/therapy
Catheter ablation/methods
Prospective studies
Randomized controlled trials
Resumé en anglais
A 4-mm cooled tip catheter was compared to an 8-mm tip catheter to cavotricuspid isthmus(CTI) ablation. This prospective study enrolled 52 patients with typical atrial flutter to ablation with a closed cooled-tip catheter(group1) or an 8-mm tip catheter. Radiofrequency(RF) applications were performed to achieve complete CTI block wich was achieved in 51 patients. No significant differences were found in the procedure parameters. CTI ablation with an irrigated tip catheter versus an 8-mm tip catheter was equally effective and satisfactorily safe for ablation of typical atrial flutter.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
SissyLaradeMelo.pdf (385.97 Kbytes)
Date de Publication
2005-10-20
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.