• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Doctoral Thesis
DOI
https://doi.org/10.11606/T.5.2005.tde-20102005-150207
Document
Author
Full name
Sissy Lara Melo
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2005
Supervisor
Committee
Sosa, Eduardo Argentino (President)
Coelho, Otavio Rizzi
Negrao, Carlos Eduardo
Pimenta, João
Zimerman, Leandro Ioschpe
Title in Portuguese
Ablação do istmo cavo-tricuspídeo para controle do flutter atrial: estudo prospectivo e randomizado comparando eficácia e segurança de cateter irrigado com cateter de 8 mm.
Keywords in Portuguese
Ablação por cateter/métodos
Ensaios controlados Aleatórios
Estudos prospectivos
Flutter atrial/terapia
Abstract in Portuguese
O cateter irrigado foi comparado com o de 8 mm para ablação com radiofrequência do istmo cavo-tricuspídeo(Ist-CT). Foram randomizados 52 pacientes portadores de flutter atrial típico para ablação com cateter irrigado(grupoI) ou com cateter de 8 mm(grupo II). O bloqueio do Ist-CT foi obtido em 51 pacientes. Não houve diferença estatística em relação aos parâmetros de aplicação de RF entre os dois grupos. A ablação do Ist-CT com cateter irrigado versus cateter de 8mm foi igualmente eficaz e segura no controle do flutter atrial típico.
Title in English
Cavotricuspid isthmus ablation for the treatment of atrial flutter: prospective randomized study comparing efficacy and safety of cooled-tip versus 8-mm-tip catheters.
Keywords in English
Atrial flutter/therapy
Catheter ablation/methods
Prospective studies
Randomized controlled trials
Abstract in English
A 4-mm cooled tip catheter was compared to an 8-mm tip catheter to cavotricuspid isthmus(CTI) ablation. This prospective study enrolled 52 patients with typical atrial flutter to ablation with a closed cooled-tip catheter(group1) or an 8-mm tip catheter. Radiofrequency(RF) applications were performed to achieve complete CTI block wich was achieved in 51 patients. No significant differences were found in the procedure parameters. CTI ablation with an irrigated tip catheter versus an 8-mm tip catheter was equally effective and satisfactorily safe for ablation of typical atrial flutter.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
SissyLaradeMelo.pdf (385.97 Kbytes)
Publishing Date
2005-10-20
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.