• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tese de Doutorado
DOI
https://doi.org/10.11606/T.5.2007.tde-10032008-132615
Documento
Autor
Nome completo
Marcus Vinicius Herbst Rodrigues
E-mail
Unidade da USP
Área do Conhecimento
Data de Defesa
Imprenta
São Paulo, 2007
Orientador
Banca examinadora
Feltrim, Maria Ignez Zanetti (Presidente)
Auler Junior, Jose Otavio Costa
Lorenzi Filho, Geraldo
Menezes, Sara Lucia Silveira de
Silva, Eliane Maria de Carvalho
Título em português
Estudo do comportamento hemodinâmico, da troca gasosa, da mecânica respiratória e da análise do muco brônquico na aplicação de técnicas de remoção de secreção brônquica em pacientes sob ventilação mecânica
Palavras-chave em português
Escarro
Mecânica respiratória
Modalidades de fisioterapia
Procedimentos cirúrgicos cardiovasculares
Processos hemodinâmicos
Reologia
Respiração artificial
Troca gasosa pulmonar
Resumo em português
INTRODUÇÃO: A aspiração traqueal (ASP) é um procedimento de rotina em pacientes sob ventilação mecânica, porém em algumas situações pode não ser eficiente. Como adjuvante usa-se a técnica "Bag-Squeezing" (BS) que consiste na hiperinflação manual associada à compressão torácica manual expiratória seguida ASP. Embora efetiva esta técnica pode apresentar algumas limitações como a desconexão do ventilador mecânico, além do controle precário do pico de pressão inspiratória (PPI) e pico de fluxo inspiratório (PFI). Como opção, podemos substituir o ressuscitador manual pelo próprio ventilador mecânico, alterando seus parâmetros e evitando assim a desconexão. Propusemos padronizar esta técnica e denominá-la PEEP-ZEEP (PZ); realizando-se a inflação dos pulmões aumentando a PEEP em 10 cmH2O, por 5 ciclos respiratórios, seguido de rápida descompressão pulmonar pela redução abrupta da PEEP até 0 cmH20, simultâneo à compressão torácica manual. OBJETIVOS: Avaliar o comportamento hemodinâmico, da troca gasosa e da mecânica respiratória, na aplicação das técnicas ASP, BS e PZ e seus efeitos na remoção de secreções brônquicas em pacientes ventilados mecanicamente. MÉTODO: 1ª etapa - "Pacientes sem secreção brônquica" estudamos prospectivamente 45 pacientes, divididos aleatoriamente em 3 grupos iguais, avaliamos os efeitos da aplicação das técnicas ASP, BS e PZ nos parâmetros hemodinâmicos, na troca gasosa e na mecânica pulmonar antes, imediatamente após, do 1o ao 10o e 30o min. subseqüentemente à aplicação das técnicas. Na 2ª etapa - "Pacientes com hipersecreção brônquica" foram estudados prospectivamente 15 pacientes ventilados mecanicamente, que apresentavam hipersecreção brônquica submetidos às técnicas ASP, BS e PZ aleatoriamente em intervalos de 2 horas, avaliamos as mesmas variáveis da 1a etapa porém acompanhamos os pacientes até 120 min. após cada intervenção. Avaliamos também o peso úmido da secreção brônquica, bem como sua reologia. RESULTADOS: 1ª etapa - Semelhantes quanto aos dados antropométricos e tempos de CEC, nossos pacientes apresentavam 59±10anos, IMC 26±3,2 kg/m2 e tempo médio de CEC de 91±19min. Houve elevação da FC somente após aplicação de BS (98±8; 106±10). PAM e SpO2 não se alteraram, observamos elevação na ETCO2 (36±6; 37±6 e 37±7; 39±8) nas técnicas BS e PZ respectivamente. Não verificamos alteração na mecânica respiratória até 30 min. após aplicação das técnicas. Durante a execução das técnicas BS e PZ respectivamente observamos elevação significante do PPI (63±17 vs 17±3), PPLATÔ (22±5 vs 26±3), PFI (154±27 vs 20±5) e PFE (86±20 vs 64±10). 2ª etapa - Nossos pacientes apresentavam 66±14anos, IMC 24±3,2 kg/m2 e tempo médio de CEC de 113±54min. A FC e a SpO2 não se alteraram, porém houve elevação significante da PAM imediatamente após a aplicação de ASP, BS e PZ (85±12 vs 101±16, 90±12 vs 100±14, 84±10 vs 97±11). Na PZ houve diminuição na ETCO2 (36±6 vs 35±7). Não observamos alteração na mecânica respiratória até 120 min. após aplicação das técnicas. Durante a execução das técnicas BS e PZ respectivamente observamos elevação significante do PPI (45±22 vs 27±3) e PFI (91±21 vs 44±17), porém a PPLATÔ (27±15 vs 26±3) e o PFE (71±20 vs 64±13) foram semelhantes entre elas. Não encontramos diferença significante no peso úmido do muco ASP(0,91±1), BS(1,09±1) e PZ(0,53±0,5), nem na análise do deslocamento e da viscoelasticidade. CONCLUSÕES: As técnicas não alteraram significantemente o comportamento hemodinâmico, de troca gasosa e de mecânica respiratória. BS e PZ foram capazes de aumentar o PFE, porém a nova proposta PZ permite maior controle das variáveis de mecânica respiratória, possibilitando monitoramento das pressões e fluxos impostos ao sistema respiratório. Todas as técnicas foram capazes de remover secreções brônquicas de forma semelhante.
Título em inglês
Airway clearance techniques in patients submitted to mechanical ventilation: A hemodynamic, gas exchange, respiratory mechanics and bronquial sputum study
Palavras-chave em inglês
Artificial respiration
cardiovascular surgical procedures and hemodynamic processes
Physical therapy modalities
Pulmonary gas exchange
Reology
Respiratory mechanics
Sputum
Resumo em inglês
INTRODUCTION: Tracheal suction (TS) is a routine procedure in patients submitted to mechanical ventilation. In association, the bag-squeezing (BS) technique is described as a manual hyperinflation associated to a manually assisted coughing followed by TS. This technique might present few limitations as its mechanical ventilator disconnection and poor control of variables such as peak inspiratory pressure (PIP) and peak inspiratory flow (PIF). We might substitute the manual ressuscitator by the mechanical ventilator itself altering its parameters and avoiding its disconnection. We proposed to standardize this technique and named it PEEP-ZEEP (PZ); inflate the lungs increasing the PEEP in 10 cmH20, trough 5 respiratory cycles, followed by an abrupt pulmonary decompression bringing the PEEP to 0 cmH20, associated to the manually assisted coughing. OBJECTIVES: Assess the hemodynamic, gas exchange and respiratory mechanics variables during the use of TS, BS and PZ techniques and assess their effects in the removal of bronchial secretions in mechanically ventilated patients. METHODS: First step - "Patients without bronchial secretions" - We assessed 45 patients prospectively, divided randomically into three groups, evaluating the effects of TS, BS and PZ techniques in the haemodynamics, gas exchange and respiratory mechanics variables before, immediately after, in the 10th and 30th minute after the technique. Second step - "Patients with bronchial secretions" - We assessed 15 mechanically ventilated patients submitted to the TS, BS and PZ techniques within 2 hours, evaluating the same variables of the first step. However we followed-up the patients until 120 minutes in each technique. We also assessed the humid weight of the bronchial secretions as well as the mucus reology. RESULTS: Results were similar when related to antropometric data and ECC period. First step - There was a raise in the HR after the BS procedure (98±8; 106±10), MAP and SpO2 did not altered. Raise in ETCO2 (36±6; 37±6 and 37±7; 39±8) in the BS e PZ techniques respectively, without alteration in the respiratory mechanics until 30 minutes after the techniques. During the BS e PZ techniques, we observed a significant increase in PIP (63±17 vs 17±3), PPLATEU (22±5 vs 26±3), PIF (154±27 vs 20±5) and PEF (86±20 vs 64±10). Second step - HR and SpO2 did not altered, there was a significant increase in MAP immediately after the TS, BS and PZ techniques (85±12 vs 101±16, 90±12 vs 100±14, 84±10 vs 97±11). The PZ technique had lower ETCO2 (36±6 vs 35±7). We did not observed any respiratory mechanics alteration until 120 minutes after the techniques. During the BS e PZ techniques, respectively, we observed an increase in the PIP (45±22 vs 27±3) and PIF (91±21 vs 44±17), however the PPLATEU (27±15 vs 26±3) and PEF (71±20 vs 64±13) were similar. The PZ technique (0,54±0,5) remove less humid weight mucus when compared to TS (0,91±1) and BS (1,09±1), but the analysis by simulated cough machine PZ (25?11) was better then TS(33?13). CONCLUSION: All techniques remove bronchial secretions and did not altered the hemodynamic, gas exchange and respiratory mechanics significantly. BS and PZ were able to enhance the PEF, however the new proposition of the PZ technique allows a better control of the respiratory mechanics variables.
 
AVISO - A consulta a este documento fica condicionada na aceitação das seguintes condições de uso:
Este trabalho é somente para uso privado de atividades de pesquisa e ensino. Não é autorizada sua reprodução para quaisquer fins lucrativos. Esta reserva de direitos abrange a todos os dados do documento bem como seu conteúdo. Na utilização ou citação de partes do documento é obrigatório mencionar nome da pessoa autora do trabalho.
TESE_MARCUS.PDF (954.96 Kbytes)
Data de Publicação
2008-03-20
 
AVISO: O material descrito abaixo refere-se a trabalhos decorrentes desta tese ou dissertação. O conteúdo desses trabalhos é de inteira responsabilidade do autor da tese ou dissertação.
  • HERBST-RODRIGUES, Marcus, et al. PEEP-ZEEP technique : cardiorespiratory repercussions in mechanically ventilated patients submitted to a coronary artery bypass graft surgery [doi:10.1186/1749-8090-6-108]. Journal of Cardiothoracic Surgery [online], 2011, vol. 6, n. 1, p. 108.
Todos os direitos da tese/dissertação são de seus autores
CeTI-SC/STI
Biblioteca Digital de Teses e Dissertações da USP. Copyright © 2001-2024. Todos os direitos reservados.