Tese de Doutorado
DOI
https://doi.org/10.11606/T.5.2009.tde-05032010-160913
Documento
Autor
Nome completo
Augusto Hiroshi Uchida
E-mail
Unidade da USP
Área do Conhecimento
Data de Defesa
Imprenta
São Paulo, 2009
Orientador
Banca examinadora
Moffa, Paulo Jorge (Presidente)
Cattani, Cesar Augusto Mastrofrancisco
Oliveira Filho, Japy Angelini
Soares, Paulo Rogério
Tsutsui, Jeane Mike
Título em português
Escore eletrocardiográfico para avaliação de isquemia miocárdica: aplicação em testes ergométricos sequenciais para avaliação do fenômeno do aquecimento
Palavras-chave em português
Doenças das coronárias
Eletrocardiografia
Isquemia miocárdica
Precondicionamento isquêmico
Teste de esforço
Resumo em português
O tempo para 1,0mm de depressão do segmento ST (T-1,0mm) adotado para caracterizar o fenômeno do aquecimento, uma expressão do precondicionamento isquêmico (PCI), em testes ergométricos sequenciais é consistente e reprodutível, porém, possui várias limitações. O objetivo deste estudo foi aplicar um escore eletrocardiográfico de isquemia miocárdica em testes ergométricos sequenciais comparando com o clássico índice T-1,0mm. Avaliamos 61 pacientes, com idade média de 62,2+7,5 anos, 86,9% homens, portadores de diabetes mellitus tipo 2 e coronariopatia multiarterial. Foram analisados 151 exames, destes 116 de pacientes completaram as duas fases de avaliação. A primeira fase compreendia dois testes ergométricos sequenciais para documentação do PCI e a segunda fase, após 1 semana, mais dois testes sob efeito de repaglinida oral. Dois observadores aplicaram o escore de forma cega. Observou-se concordância perfeita inter e intraobservador (Kendall Tau-b = 0,96, p<0,0001, Kendall Tau-b=0,98, p<0,0001, respectivamente). Os valores de sensibilidade, especificidade, valor preditivo negativo, valor preditivo positivo e acurácia, foram respectivamente de 72,41%, 89,29%, 75,8%, 87,5% e 81%. Concluímos que o escore de isquemia é um método consistente e reprodutível para documentação do fenômeno do aquecimento, representando uma alternativa factível ao índice T-1,0mm.
Título em inglês
Electrocardiographic score for myocardial ischemia evaluation: application in sequential exercise tests for warm-up phenomenon evaluation
Palavras-chave em inglês
Coronary disease
Electrocardiography
Exercise test
Ischemic preconditioning
Myocardial ischemia
Resumo em inglês
The time to 1.0mm ST-segment depression (T-1.0mm), adopted to document the warm-up phenomenon, an expression of the ischemic preconditioning (IPC), during sequential exercise tests is considered reliable and reproductible, although with several limitations. The main goal of this study was to apply an electrocardiographic ischemic myocardium score to sequential exercise tests, comparing with the standard T-1.0mm. We evaluated 61 patients, mean age 62,2+7,5 years-old, 86.9% male, with type 2 diabetes mellitus and multivessel coronary disease. We analyzed 151 exercise tests, being 116 tests from patients who fulfilled the two phases of the study. The first phase enrolled the patients for two sequential exercise tests to document the IPC and the second phase, after 1 week, two additional sequential exercise tests were performed under repaglinide treatment. We observed a perfect concordance inter and intraobserver (Kendall Tau-b=0.96, p<0.0001; Kendall Tau-b=0,98, p<0,0001, respectively). The sensibility, specificity, positive predictive value and negative predictive value were also determined: 72.41%, 89.29%, 75.8%, 87.5% and 81%, respectively. In conclusion, the electrocardiographic ischemic score is a consistent and reproductible tool to document the warm-up phenomenon, representing a reliable alternative to the T-1.0mm.
 
AVISO - A consulta a este documento fica condicionada na aceitação das seguintes condições de uso:
Este trabalho é somente para uso privado de atividades de pesquisa e ensino. Não é autorizada sua reprodução para quaisquer fins lucrativos. Esta reserva de direitos abrange a todos os dados do documento bem como seu conteúdo. Na utilização ou citação de partes do documento é obrigatório mencionar nome da pessoa autora do trabalho.
AugustoHiroshiUchida.pdf (730.43 Kbytes)
Data de Publicação
2010-03-15
 
AVISO: Saiba o que são os trabalhos decorrentes clicando aqui.
Todos os direitos da tese/dissertação são de seus autores
CeTI-SC/STI
Biblioteca Digital de Teses e Dissertações da USP. Copyright © 2001-2024. Todos os direitos reservados.