Doctoral Thesis
DOI
https://doi.org/10.11606/T.5.2011.tde-02122011-102500
Document
Author
Full name
Esteban Wisnivesky Rocca Rivarola
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2011
Supervisor
Committee
Sosa, Eduardo Argentino (President)
Cirenza, Cláudio
Oliveira Júnior, Múcio Tavares de
Pimenta, João
Rochitte, Carlos Eduardo
Title in Portuguese
Análise espectral de sinais atriais e sua correlação topográfica com a inervação parassimpática cardíaca
Keywords in Portuguese
Ablação por cateter
Análise espectral
Fibrilação atrial
Sistema nervoso parassimpático
Abstract in Portuguese
Objetivo. Verificar se as características espectrais dos eletrogramas atriais (EgA) em ritmo sinusal (RS) se correlacionam com a presença de gânglios parassimpáticos cardíacos. Materiais e Resultados. Treze pacientes encaminhados para submeter-se a ablação de fibrilação atrial (FA) foram incluídos de forma prospectiva. Previamente ao início da ablação, realizou-se o registro de EgA em RS em uma série de regiões anatômicas pré-determinadas, seguindo-se uma ordem sequencial. Em seguida, aplicou-se estímulos elétricos de alta frequência (20 Hz de frequência, amplitude de 100 V e duração de pulso de 4 ms), nos mesmos locais. Uma resposta vagal evocada foi definida como um súbito aumento no intervalo RR ou a indução de bloqueio na condução átrio-ventricular imediatamente após a aplicação do estímulo de alta-frequência (EAF). Procedeu-se à análise espectral dos sinais atriais em RS registrados, com amostragem de 1000 Hz, janela Hanning. No total, 1488 EgA oriundos de 186 locais anatômicos foram registrados, sendo 129 de regiões com resposta vagal negativa e 57 correspondentes a regiões de resposta vagal positiva. A duração do eletrograma e o número de deflecções foram similares nos pontos com resposta vagal positiva e negativa. A densidade de potência espectral em locais de resposta vagal positiva, no entanto, foi menor entre 26 e 83 Hz, e maior entre 107 e 200 Hz, comparados com os locais de resposta negativa. A área sobre a curva entre 120 e 170 Hz normalizada para a área total do espectro foi testada como um novo parâmetro diagnóstico. A análise de curva ROC demonstrou que o valor area 120-170 / area total > 0,14 foi capaz de identificar locais de inervação vagal com sensibilidade de 70,9% e especificidade de 72,1%. Conclusão. A análise espectral de sinais atriais durante RS é um método factível e simples de mapear os locais de inervação parassimpática cardíaca, sem a necessidade de qualquer tipo de estimulação
Title in English
Spectral analysis of atrial signals and its topographic correlation with cardiac parassimpathetic innervation
Keywords in English
Atrial fibrillation
Catheter ablation
Parasympathetic nervous system
spectral analysis
Abstract in English
Objective. To verify whether spectral components of atrial electrograms (AE) during sinus rhythm (SR) correlate with cardiac ganglionated plexus (GP) sites. Methods and Results. Thirteen patients undergoing atrial fibrillation (AF) ablation were prospectively enrolled. Prior to radio frequency application, endocardial AE were recorded with a sequential point-by-point approach. Electrical stimuli were delivered at 20 Hz, amplitude 100 V, and pulse width of 4 msec. A vagal response was defined as a high-frequency stimulation (HFS) evoked AV block or a prolongation of RR interval. Spectral analysis was performed on single AE during SR, sampling rate of 1000 Hz, Hanning window. Overall, 1488 SR electrograms were analyzed from 186 different left atrium sites, 129 of them corresponding to negative vagal response sites and 57 to positive response sites. The electrogram duration and the number of deflections were similar in positive and negative response sites. Spectral power density of sites with vagal response was lower between 26 and 83 Hz and higher between 107 and 200 Hz compared with negative response sites. The area between 120 and 170 Hz normalized to the total spectrum area was tested as a diagnostic parameter. ROC curve analysis demonstrated that an area 120-170 / area total value > 0,14 identified vagal sites with 70,9% sensitivity and 72,1% specificity. Conclusions. Spectral analysis of AE during SR is feasible and simple method of mapping the cardiac autonomic nervous system (ANS), with no stimulation required
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2011-12-05
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI