Master's Dissertation
DOI
https://doi.org/10.11606/D.46.2017.tde-31102016-090427
Document
Author
Full name
André Luiz Rosa
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2016
Supervisor
Committee
Petri, Denise Freitas Siqueira (President)
Breitkreitz, Márcia Cristina
Silva, Rodrigo César da
Title in Portuguese
Caracterização físico-química de sistemas coloidais em sprays nasais
Keywords in Portuguese
Análise de partículas
Celulose microcristalina
Planejamento de experimentos
Reologia
Spray nasal
Abstract in Portuguese
Neste trabalho avaliou-se o comportamento coloidal de suspensões nasais contendo micropartículas de celulose (MCC-NaCMC) com o objetivo de desenvolver um produto genérico compatível com o produto referência de mercado. As propriedades reológicas destas formulações possuem alta influência nos atributos críticos de qualidade do produto, como uniformidade de dose, devido sedimentação durante estocagem em prateleira, e também na performance in-vitro/ in-vivo. Realizaram-se testes com diferentes concentrações de MCC-NaCMC e diferentes parâmetros de processo (tempo e taxa de cisalhamento) utilizando um planejamento de experimentos (DoE) de superfície de respostas através de um modelo composto central. As respostas avaliadas foram tamanho de partículas (quantidade em porcentagem de partículas menores que 1µm e D90) através da técnica por difração a laser e viscosidade/tixotropia através de um reômetro rotacional. Influências significativas dos três fatores e efeitos sinérgicos entre eles nas respostas analisadas foram observadas. Desta maneira foi possível obter respostas próximas ao do produto referência de mercado através deste mapeamento. Observou-se também uma alta correlação entre as respostas, pois este estudo mostrou que o tamanho das partículas coloidais controla a viscosidade e tixotropia das dispersões coloidais. Este trabalho mostrou a significativa influência das etapas de processo no comportamento coloidal das formulações. Idealmente o processo deveria ser monitorado por medidas reológicas, porém este controle é inviável devido ao tempo para a reestruturação do sistema (24 horas). Portanto, a melhor alternativa seria o monitoramento do processo por análise de tamanho de partículas online.
Title in English
Physical-chemistry characterization of colloidal systems in nasal sprays
Keywords in English
DoE
Microcrystalline cellulose
Nasal spray
Particle size analysis
Rheology
Abstract in English
In this work, the colloidal behavior of nasal suspensions containing cellulose microparticles (MCC-NaCMC) was evaluated, in order to develop a generic product compatible with the brand-name product. The rheological properties of these formulations have high influence on the critical quality attributes of the product, such as dose uniformity, due to sedimentation during shelf life, and also on in-vitro/in-vivo performance. Tests were performed with different concentrations of MCC-NaCMC and different process parameters (time and shear rate) using a Design of Experiments (DoE) with response surface by central composite design. The responses evaluated were particle size (amount in percentage of particles smaller than 1m and D90) by means of laser diffraction, and viscosity / thixotropy using a rotational rheometer. Significant influences of the three factors and synergic effects among responses were observed. Through this mapping it was possible to obtain nearby responses to the brand-name product. There was also a strong correlation between the responses, because the size of colloidal particles controlled the dispersion viscosity and thixotropy. This study showed the significant influence of the process steps on the colloidal behavior of the formulations. Ideally the process should be monitored by rheological measurements, but this control is not feasible due to the time required for the system rebuilding (24 hours). Therefore, the best alternative would be monitoring the process by the online particle size analysis.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2017-02-16
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.