Disertación de Maestría
DOI
https://doi.org/10.11606/D.46.2018.tde-12042018-083705
Documento
Autor
Nombre completo
Rafael Carlucci Tavares
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2017
Director
Tribunal
Adamowski, Julio Cezar (Presidente)
Garcia, Roberto
Nan, Pai Chi
Título en portugués
Investigação da força de união de juntas aparafusadas com o auxílio da técnica de ultrassom
Palabras clave en portugués
Força
Parafuso
Porca
Pulso-eco
Ultrassom
Resumen en portugués
O presente estudo propõe investigar o método para estimar a força exercida pelo parafuso na junta aparafusada, propondo uma possível substituição a célula de carga convencional. Com base na técnica pulso-eco ultrassônico, verificando o tempo de propagação da onda em um parafuso retificado antes e após ser submetida a uma carga normal. A diferença de tempo correlacionada à força medida pela célula de carga foi realizada após a aplicação de um torque de aperto na região elástica da fixação. As amostras de parafuso foram retificados nas suas extremidades paralelas, o aparelho ultrassônico com transdutor de 5MHz de 6mm de diâmetro foi acoplado magneticamente sob o parafuso utilizando gel a base dágua como acoplante, para assim verificar o deslocamento, no tempo, do sinal do eco que é detectado por um limiar de amplitude desse sinal, o tempo de voo do pulso-eco longitudinal no meio isotrópico foi o objeto do estudo para correlacionar com a força medida em uma célula que mede força (kN). A diferença do tempo do pulso ultrassônico foi causado por um esforço longitudinal após um torque aplicado na região elástica de resistência mecânica do parafuso na junta simulada, utilizando um equipamento que basicamente é formado por célula de carga longitudinal e torcional com torquímetro eletrônico transdutorizado para efetuar o aperto gradativo. Este equipamento é atualmente usado para verificar o atrito de elementos roscados e as interações de inúmeras possibilidades de superfícies de contato, tais quais porcas e parafusos, conforme fórmulas da norma ISO16047.
Título en inglés
Investigation of the clamp force of bolted joints with the aid of the ultrasound technique
Palabras clave en inglés
Bolt
Echo-pulse
Force
Nut
Ultrasound
Resumen en inglés
The present study proposes to investigate the method to estimate the force exerted by the screw in the bolted joint, proposing a possible replacement to the conventional load cell. Based on the pulse-echo technique ultrasonic, checking the wave propagation time in a rectified screw before and after being subjected to a normal load. The time difference correlated to the force measured by the load cell was performed after the application of a tightening torque in the elastic region of the fixation. The screw samples were rectified at their parallel ends, the ultrasonic apparatus with a 5MHz of 6mm diameter was magnetically coupled under the screw using water-based gel as a coupling, to thereby verify the time shift of the echo signal that is detected by a threshold amplitude of that signal, the flight time of the pulse-echo in the isotropic medium was the object of the study to correlate with the force measured in a cell that measures force (kN). The difference of the time of the ultrasonic pulse was caused by a longitudinal effort after a tightening torque applied in the elastic region of mechanical resistance of the screw in the simulated joint, using equipment that basically is formed by cell of longitudinal and torsional load with electronic transduced torque wrench to define the gradual tightening. This equipment is currently used to check the friction of threaded elements and the numerous possibilities of contact surfaces, such as nuts and bolts, according to ISO16047 formulas.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2018-04-26
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.