Disertación de Maestría
DOI
https://doi.org/10.11606/D.46.2014.tde-30092014-110547
Documento
Autor
Nombre completo
Pedro Alves Machado
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2014
Director
Tribunal
Agostinho, Silvia Maria Leite (Presidente)
Gutz, Ivano Gebhardt Rolf
Santos, Celia Aparecida Lino dos
Título en portugués
Estudo da atuação e sinergismo de inibidores de corrosão para o aço inoxidável austenítico 304 em meio de ácido peracético comercial 0,2%
Palabras clave en portugués
Ácido peracético
Aço 304
Benzotriazol
Corrosão
Dodecilsulfato de sódio
Inibidores
Resumen en portugués
O ser humano tem uma grande necessidade de se proteger de fontes de contaminação microbianas. Para tal, ao longo da história, diversos meios foram empregados, desde lavagem com água corrente até as mais modernas substâncias esterilizantes. Entre essas, o ácido peracético (APA) é o mais seguro, sob o ponto de vista ambiental, além de não ser cancerígeno ou tóxico para o corpo humano. O maior empecilho para a aplicação do APA em certas superfícies é seu caráter fortemente oxidante, que pode causar danos em materiais metálicos. Para que tal aplicação seja viável, é necessária a aplicação de inibidores de corrosão que reduzam os danos que o APA possa causar. Para tanto, foram estudadas sete substâncias empregadas comercialmente como inibidores de corrosão para aço inoxidável 304 em meio de ácido peracético a temperatura ambiente: benzotriazol (BTAH), molibdato de sódio, tungstato de sódio, fosfato monossódico, fosfato dissódico, hexametafosfato de sódio e dodecilsulfato de sódio (SDS) e, posteriormente, sinergismos entre os mesmos. Seus desempenhos foram estudados por diferentes técnicas eletroquímicas: potencial de circuito aberto, polarização linear potenciodinâmica, cronoamperometria, espectroscopia de impedância eletroquímica. A superfície do aço foi estudada por microscopia eletrônica de varredura (MEV). As técnicas eletroquímicas demonstraram que o aço 304 encontra-se passivado em meio de ácido peracético 0,2%. Sua resistência à corrosão pode ser significativamente aumentada com o emprego de BTAH, e de sua mistura com SDS, chegando a uma eficiência inibidora de 70%. Os outros inibidores ou pares de inibidores estudados apresentaram eficiências mais baixas. Ensaios microbiológicos foram realizados com o objetivo de se determinar se os inibidores de corrosão poderiam interferir no desempenho do APA como esterilizante. Os resultados obtidos comprovaram que a presença dos inibidores de corrosão BTAH e SDS não interfere sobre a ação esterilizante do APA.
Título en inglés
Study of the effect and synergism between corrosion inhibitors over the 304 austenitic stainless steel in 0,2% commercial peracetic acid media
Palabras clave en inglés
304 steel
Benzotriazol
Corrosion
Inhibitors
Peracetic acid
Sodium dodecilsulfate
Resumen en inglés
The humanity has a great need to protect itself from microbial contamination. For that, through the history, several ways were employed, since running water washing until the most modern sterilizing substances. Between those, the peracetic acid (PAA) is the safest, under an environmentalist view, besides not being carcinogenic nor toxic to the human body. The great trouble to the application of PAA in some surfaces is its high oxidative property, which can cause damage to metallic materials. Therefore the application of corrosion inhibitor is necessary to reduces the damage that PAA might cause. For that, seven substances commercially applied as corrosion inhibitors for the 304 stainless steel in peracetic acid media were studied: benzotriazole (BTAH), sodium molybdate, sodium tungstate, monosodic phosphate, disodic phosphate, sodium hexametaphophate and sodium dodecilsulphate, as well as the synergism between them. Their per formances were studied through several electrochemical techniques: open circuit potential, linear polarization, chronoamperometry and electrochemical impedance spectroscopy. The steel surfaces were studied through scanning electronic microscopy (SEM). The electrochemical techniques showed that the 304 stainless steel presents passive behavior in 0.2% PAA media. Its corrosion resistance can be significantly improved through the application of BTAH alone, and in combination with SDS, achieving 70% of inhibitor efficiency. The other inhibitors and mixtures studied presented lower efficiency. Microbiological studies were performed aiming to define if the corrosion inhibitor could interfere with the PAA sterilizing performance. The results proved that the presence of BTAH and SDS corrosion inhibitors did not interfere with the sterilizing properties of PAA.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2014-11-06
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.