Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.46.2012.tde-28032012-104252
Document
Auteur
Nom complet
Raquel Rainone
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2011
Directeur
Jury
Oliveira, Pedro Vitoriano de (Président)
Bazito, Reinaldo Camino
Silva, Júlio César José da
Titre en portugais
Avaliação de métodos analíticos para determinação de Na, K, Ca, Mg, P e S em biodiesel por ICP OES
Mots-clés en portugais
Biodiesel
Digestão
Emulsão
ICP OES
Introdução direta
Padrão interno
Resumé en portugais
Esse trabalho avaliou três diferentes procedimentos de preparo de amostra para determinação de Na, K, Ca, Mg, P e S em biodiesel por ICP OES. O primeiro procedimento avaliado foi uma modificação daquele proposto pela ANP para o controle da qualidade do biodiesel, onde a amostra foi introduzida diretamente no equipamento com e sem diluição em solvente orgânico (querosene ou xilol). Essa forma de preparo, apesar de ser bastante simples, apresentou interferências físicas graves que só puderam ser corrigidas com o uso de vaselina líquida nas soluções de calibração do equipamento para igualar a viscosidade às amostras e com o uso do carbono como padrão interno. O segundo método estudado baseou-se na introdução de biodiesel na forma de emulsão. Para esse caso, preparou-se emulsões contendo 500 mg de biodiesel, 1% m v-1 de Triton X-100 como agente emulsificante e 10% v v-1 de ácido nítrico, misturados com água ultra-pura até o volume final de 10 mL. Esse método de preparo foi bastante simples e eliminou as grandes dificuldades de se trabalhar com solução orgânica no plasma. No entanto, o agente emulsificante apresentou elevadas concentrações de alguns dos analitos, aumentando o sinal dos brancos, além de gerar resultados com altos desvios padrões. O terceiro método foi a digestão das amostras usando aquecimento assistido por micro-ondas. Esse método eliminou quase que completamente a matriz orgânica, gerando os menores limites de detecção e tornou a introdução da amostra no equipamento mais fácil. Contudo, o tempo de preparo da amostra para o método da digestão, assim como os custos associados a este método, foram os maiores obtidos em relação aos outros. Outro ponto negativo foi e elevado fator de diluição desse método que dificultou a detecção dos analitos. Testes de adição e recuperação de analitos foram realizados nos três métodos e os resultados obtidos nos três casos ficaram dentro da faixa considerada satisfatória de 80 a 120% de recuperação. Ao final do desenvolvimento, 7 amostras foram analisadas pelos três métodos e seus resultados comparados. Em certos casos, a comparação foi dificultada pelo grande número de resultados abaixo dos limites de detecção. No entanto, pôde-se observar que, com exceção do S, os resultados obtidos pelos diferentes métodos não apresentaram boa concordância entre si. Entretanto, devido à falta de material certificado, não se pode avaliar qual método seria o mais exato. Todavia, considerando-se o preparo mais simples e com a menor taxa de diluição, a análise de biodiesel puro (100%), com o uso do carbono como padrão interno foi considerado o método com resultados mais confiáveis.
Titre en anglais
Evaluation of analytical methods for the determination of Na, K, Ca, Mg, P and S by ICP OES
Mots-clés en anglais
Biodiesel
Digestion
Direct introduction
Emulsion
ICP OES
Internal standard
Resumé en anglais
The present work has evaluated three different sample preparation methods for determination of Na, K, Ca, Mg, P and S in Biodiesel by ICP OES. The first one was similar to the method required by ANP for Biodiesel quality control, based on the introduction of organic samples into the ICP. In this case, the samples were analyzed with and without dilution in organic solvents (kerosene or xylol). Even though this sample preparation procedure has shown to be very simple, the physical interferences observed were severe and required the use of two different strategies to be overcome: addition of high viscosity oil (vaseline) to the calibration solutions and carbon as internal standard. The second method was based on the introduction of Biodiesel emulsion into the ICP. These emulsions were prepared by the addition of 500 mg of sample, 1% w v-1 Triton X-100 as emulsifying agent and 10% v v-1 of nitric acid in ultrapure water up to 10 mL of final volume. Although this simple sample preparation method has eliminated the challenges associated with the use of organic solvents, the blank solution presented a high concentration of some analytes, due to the contamination by the emulsifying agent and this method generated results with high blank signal and standard deviation. The third method was based on microwave assisted digestion of Biodiesel samples. This method was the only one capable of eliminating the organic matrix and all the challenges associated with it, which made the sample introduction easier and improved the method detection limits. Nevertheless, the time consumed in this sample preparation was higher than in the other cases, as also were the associated costs of analysis. The dilution factor was also very high, making difficult the detection of the analytes. The spike recoveries obtained for each method were in the range of 80 to 120%, which were considered satisfactory. Seven different samples were analyzed by each method, but the comparison of the results was difficult because many results were lower than the detection limits. Even though, it was possible to conclude that the concentrations obtained in each method were very different for all elements, excluding S. Without a certified reference material, it was not possible to point out which results were more exact, but considering the simpler sample preparation procedure, with the lower dilution factor, we concluded that the direct analysis of Biodiesel 100%, using carbon as an internal standard was the method that presented more reliable results
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2012-05-14
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.