Leandro Mota Santos
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2015
Supervisor
Committee
Oliveira, Pedro Vitoriano de (President)
Gaubeur, Ivanise
Serrano, Silvia Helena Pires
Title in Portuguese
Proposta de método para determinação de Pt em sangue total visando o uso como biomarcador de exposição ambiental por veículos automotivos
Keywords in Portuguese
Absorção atômica
Extração em ponto nuvem
Forno de grafite
Platina
Sangue
Abstract in Portuguese
Reflexo de um modo de vida que exige locomoção rápida e com um mínimo de conforto, atualmente, nas grandes metrópoles, há um grande número de veículos em circulação que emitem gases poluentes (hidrocarbonetos, CO e óxidos de nitrogênio - NOx). Para minimizar a emissão desses gases, os carros atuais são dotados de conversores catalíticos, formados pelos metais do grupo da platina, com a finalidade de converter gases nocivos em gases menos agressivos ao ambiente e ao homem. Porém, esses elementos constituintes dos conversores catalíticos podem ser expelidos para o ambiente, na forma de materiais particulados em suspensão, por volatilização ou junto com os gases da combustão. Desta forma, esses elementos podem acumular-se nos mais diversos ambientes. A utilização de amostras biológicas, tal como sangue, na investigação e no controle à exposição de elementos nos seres humanos vem sendo praticada há muito tempo. Estudos com materiais biológicos apontam que as concentrações de metais do grupo da Platina estão na ordem de ng/kg. Tais níveis de concentração representam um grande desafio para a Química Analítica, pois são muito baixos para que se tenham resultados com boa precisão e exatidão nas análises, mesmo utilizando técnicas muito sensíveis. Como alternativa para contornar os problemas, nas determinações destas baixas concentrações, etapas prévias de pré-concentração, com posterior determinação, vem sendo propostas com sucesso. Nessa pesquisa, para a pré-concentração dos analito, extração em ponto nuvem foi empregada com determinação por espectrometria de absorção atômica por forno de grafite. O procedimento da extração em ponto nuvem consiste em derivatizar os analitos em espécies hidrofóbicas por meio de um agente complexante, e extrair por micelas formadas a partir de um surfactante não iônico, induzidas por mudança de temperatura. Essa extração se baseia no fenômeno que ocorre com a formação de agregados micelares, quais apresentam caráter hidrofóbico. Foram estudados diferentes ligantes, e o melhor resultado para a extração foi obtido empregando-se o APDC (pirrolidina ditiocarbamato de amônio). Os parâmetros da extração em ponto nuvem otimizados para o melhor ligante foram: pH=7; 3,0x10-2 mol L-1 de APDC; 0,5 % m v-1 de Triton X-114; 60ºC durante 10 min de banho, 10 min de centrifugação e 50 mg L-1 Cu(II) como modificador químico. O método apresentou fator de enriquecimento de 24 vezes, mas o LOD (0,24 µg L-1) ficou muito acima dos valores apresentados em amostras de indivíduos expostos e não expostos. Adições de 1, 5 e 10 µg L-1 foram realizadas para avaliar a exatidão do método e apresentaram recuperações média de 91%.
Title in English
A method for determination of Pt in whole blood in order to use as biomarker of environmental exposure by automotive vehicles.
Keywords in English
Atomic absorption
Blood
Cloud point extraction
Graphite furnace
Platinum
Abstract in English
Reflecting a way of life that requires fast displacement with a minimum of comfort, currently in big cities, there are a large number of vehicles that produce a large amount of waste gases (hydrocarbons, CO and nitrogen oxides - NOx) to atmosphere. To minimize the emission of these gases, current cars are equipped with catalytic converter, made of platinum group metals, which has the purpose of converting the noxious gases into less harmful gases to environment and man. However, these constituents of the catalytic converter can be expelled to the environment in form of particulates in suspension, or by volatilization along with the combustion gases. Thus, these elements can accumulate. Biological samples such as blood, urine, hair, nail, have been used for a long time in studies and control of human exposition to elements. Studies of biological materials indicate that the concentrations of platinum group metals are the order of ng/kg. Such concentration levels means a huge challenge for analytical chemistry, as they are too low to provide the necessary results with good precision and accuracy in the analysis, even using very sensitive techniques. As an alternative to overcome the problems in the provisions of these low concentrations, preconcentration methods, with subsequent determination has been proposed successfully. Cloud point extraction (CPE) was proposed in this work for pre-concentration of the analytes. CPE procedure consists in derivatizing the analytes into hydrophobic species by a complexing agent and extracts them trapped inside micelles formed from a nonionic surfactant, induced by temperature change. The cloud point extraction is based on the phenomenon that occurs with the formation of these hydrophobics aggregates by those micelles. Dithizone, DBTC, DMG, DDTC and APDC ligands were studied. The optimized parameters of cloud point extraction were: pH=7; 3,0x10-2 mol L-1 APDC; 0,5% m v-1 Triton X-114; 60 ºC while 10 min of termal bath and 10 min of centrifugation time. A Cu (II) 50 mg L-1 solution was used as a chemical modifier. The method was evaluated after optimized cloud point extraction's parameters conditions. It showed enrichment factor of 24-fold, but the limit of detection (0.24 µg L-1) was higher than the values expected to samples of exposed and non exposed individuals. A recovery test was done and a satisfactory recovery result was provided, up to 91%.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2015-11-06
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.