Doctoral Thesis
DOI
https://doi.org/10.11606/T.46.2017.tde-16082017-113454
Document
Author
Full name
Daniel Menezes Silvestre
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2017
Supervisor
Committee
Nomura, Cassiana Seimi (President)
Gaubeur, Ivanise
Lago, Claudimir Lucio do
Oliveira, Pedro Vitoriano de
Santos Junior, Dario
Title in Portuguese
Avaliação de parâmetros na análise direta de madeira por LIBS
Keywords in Portuguese
Análise direta
Calibração
Classificação
Emissão atômica
LIBS
Madeira
Abstract in Portuguese
A espectrometria de emissão óptica com plasma induzido por laser (LIBS) tem se tornado uma técnica muito atrativa e bastante explorada nas análises químicas e tem ganhado destaque devido à disponibilidade de instrumentos portáteis, o qual possibilita a análise in situ. Por outro lado, a análise quantitativa tem sido considerada o "calcanhar de Aquiles" da técnica, face as suas dificuldades em executá-la, em especial devido à complexa interação laser-matriz. Nesse contexto, o uso de métodos de calibração apropriados é imperativo. Neste trabalho avaliou-se a possibilidade de empregar LIBS na identificação, discriminação e quantificação elementar em amostras de madeira, uma vez que essa matriz tem grande importância econômica e ambiental. O desenvolvimento de método envolveu a otimização dos parâmetros instrumentais (diâmetro de focalização de 50µm, energia por pulso de 20 mJ, taxa de repetição de 10 Hz, tempo de atraso de 0,25µs, padrão de análise percurso, 300 pulsos de laser, deslocamento da amostra de 0,15 mm/s e fluxo de argônio de 1,0 L/min), bem como a avaliação da influência da umidade, tamanho de partícula e homogeneidade nos resultados analíticos. Diversos métodos de calibração também foram estudados, entre eles, a calibração empregando diferentes CRMs que geraram resultados com erros relativos superiores a 30%. Calibração construída com madeira Pinus adicionada com concentrações crescentes de analito foi a que apresentou os melhores resultados (erros relativos< 20%). Outra abordagem envolveu a confecção de um branco analítico por meio da lavagem da madeira, seguida pela adição elementar o qual apresentou resultados com erros relativos de até 14%, mostrando-se bastante promissora. Apesar disso, aplicações em amostras in natura não é trivial devido à sua baixa homomogeneidade e especialmente devido ao fato de o analito naturalmente presente na amostra interagir de forma diferente ao analito artificialmente adicionado à matriz. A aplicação do LIBS na avaliação da distribuição elementar nos anéis de crescimento de árvores foi eficiente, assim como na discriminação e identificação de amostras de madeira que atingiu 100% de exatidão no índice de acerto quando aplicado KNN.
Title in English
Evaluation of parameters in direct analysis of wood by LIBS
Keywords in English
Atomic emission
Calibration
Classification
Direct analysis
LIBS
Wood
Abstract in English
Laser-induced breakdown spectroscopy (LIBS) has become a very attractive and well-exploited technique in chemical analysis and has gained prominence due to the availability of portable instruments, which enables in situ analysis. On the other hand, quantitative analysis has been considered the "Achilles heel" of this technique, especially due to the strong matrix interference caused by complex laser-matrix interaction. In this context, the use of appropriate calibration methods is imperative.In this work the possibility of using LIBS in the identification, discrimination, and elemental quantification in wood samples was evaluated, since this matrix has an economic and an environmental importance. The method development involved the optimization of the instrumental parameters (50 µm of spot size, 20 mJ of energy by pulse, 10 Hz of pulse repetition rate, 0.25 µs of delay time, raster, 300 laser pulses, sample velocity of 0.15 mm/s and argon flow of 1.0 L/min), as well as the influence of moisture, particle size and homogeneity onto the analytical results. Several calibration methods were also studied, among them, the calibration using different CRMs which was not a good purpose since relative errors higher than 30% on the results were found. The calibration made with Pinus wood spiked with increasing concentrations of analytes showed the best results (relative errors <20%) for wood analysis. Another approach involved the preparation of an analytical blank by washing wood samples with 0.1% HNO3, followed by spiking of increasing concentration of analytes. In this case, relative errors of up to 14% were found, suggesting it is a promising approach. Despite this, applications of these proposed methods in quantitative analysis of in natura wood samples are not trivial due to their low homomogeneity and especially due to the differences on interaction between laser and naturally occurring analyte and artificially spiked analyte. The application of LIBS in the evaluation of the elemental distribution in the tree growth rings was efficient, as well as in the discrimination and identification of wood samples since 100% accuracy were reached when KNN was applied.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2017-08-28
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.