Titre en portugais
Desenvolvimento de sensores e de métodos analíticos para determinação de compostos de interesse farmacêutico
Mots-clés en portugais
C4D
Eletroforese capilar
Fármacos
FIA
Métodos eletroanalíticos
Sensores
Resumé en portugais
A crescente demanda por produtos farmacêuticos tem como consequência a necessidade de elaboração de novos procedimentos analíticos que, via de regra, apresentem características como: elevada frequência analítica, simplicidade, ausência de substâncias altamente tóxicas, e com baixo custo para o controle de qualidade dos fármacos lançados no mercado. Neste trabalho descreve-se o desenvolvimento de procedimentos para determinação de N-acetilcisteína (NAC), nimesulida (NMS), trimetoprima (TMP) e sulfametoxazol (SMX) em formulações farmacêuticas usando técnicas eletroanalíticas e métodos de separação. Na determinação da NAC foi usado um eletrodo de grafite pirolítico modificado com ftalocianina de cobalto (CoPc) em 0,1 mol L-1 de NaOH. Este sensor mostrou intensa catálise para NAC produzindo um aumento na corrente anódica de cerca de 700 vezes quando comparado com o eletrodo limpo. Um procedimento em FIA foi proposto usando este sensor, e a curva analítica foi linear no intervalo 5,0 × 10-5 a 1,0 × 10-3 mol L-1, com coeficiente de correlação maior que 0,999. O DPR de 1,1% (n = 13) foi obtido para uma solução contendo 5,0 × 10-4 mol L-1 de NAC. Além disso o método apresentou LD e LQ de 9,0 ×10-7 mol L-1 e 3,0 × 10-6 mol L-1, respectivamente. A determinação eletroanalítica de NMS foi conduzida em solução de 1,0 mol L-1 de NaOH usando eletrodo de carbono vítreo, meio em que não ocorre envenenamento da superfície do eletrodo. Desse modo, um método eletroanalítico usando voltametria de onda quadrada foi elaborado para análise de NMS. Nas condições ótimas de análise o método apresentou uma faixa linear no intervalo de 4,3 × 10-5 a 4,2 × 10-4 mol L-1, com limite de detecção de 3,2 × 10-6 mol L-1. A precisão do método foi avaliada em um mesmo dia de análise por sucessivas medidas voltamétricas (n = 10) em solução de hidróxido de sódio 1,0 mol L-1 contendo 1,0 × 10-4 mol L-1 de NMS, sem a necessidade de renovação da superfície do eletrodo. Os resultados para esta série de medidas foram avaliados e o DPR calculado foi somente 1,2%, indicando que nessas condições o eletrodo apresentou uma resposta estável além de não sofrer qualquer efeito de envenenamento. Para a determinação simultânea de TMP e SMX foi desenvolvido um método analítico empregando eletroforese capilar com detecção condutométrica sem contato (C4D). Usando uma solução 10 mmol L-1 lítio-fosfato (pH 7,1 ) como tampão de corrida, a faixa linear de trabalho obtida para ambos os analitos foi de 12,5 a 200 × 10-6 mol L-1 com R > 0,999. Nas condições de análise foram obtidos LDs de 1,1 × 10-6 mol L-1 para a TMP, e 3,3 × 10-6 mol L-1 para o SMX com um tempo total de análise de 2,6 minutos.
Titre en anglais
Development of sensors and analytical methods for determination of compounds of pharmaceutical relevance
Mots-clés en anglais
C4D
Capillary electrophoresis
Electroanalytical methods
FIA
Pharmaceuticals
Sensors
Resumé en anglais
The growing demand for pharmaceutical products has created need for developing new analytical procedures that, as a rule, exhibit characteristics like, high sampling rate, simplicity, absence of highly toxic substances, and low cost for quality control of drugs launched in market. In this work, electroanalytical and capillary electrophoresis methods for determination of N-acetylcysteine (NAC), nimesulide (NMS), trimethoprim (TMP) and sulfamethoxazole (SMX) in pharmaceutical formulations were proposed. For NAC determinations a pyrolytic graphite electrode modified with CoPc in 0.1 mol L-1 NaOH was used. This new sensor showed to be catalytic for this compound producing an anodic current increase of 700 times when compared with bare electrode. A FIA procedure was proposed using this new sensor, and the method showed a linear response in a range of 5.0 × 10-5 to 1.0 × 10-3 mol L-1 with correlation coefficient better than 0.999. RSD of 1.1% (n = 13) was obtained for a solution containing 5.0 × 10-4 mol L-1 NAC. Furthermore the method presented DL and QL of 9.0 × 10-7 mol L-1 and 3.0 × 10-6 mol L-1, respectively. NMS electroanalytical determination was conducted in a 1.0 mol L-1 NaOH solution using a glassy carbon electrode. In strongly alkaline medium it was verified that NMS does not produce poisoning of the electrode surface. Thus an electroanalytical method using square wave voltammetry was proposed for analysis of NMS. In the optimal analysis conditions proposed method showed a linear response in a range of 4.3 × 10-5 to 4.2 × 10-4 mol L-1, with detection limit of 3.2 × 10-6 mol L-1. Accuracy of the method was evaluated on the same day by successive voltammetric measurements (n = 10) in a 1.0 mol L-1 sodium hydroxide solution containing 1.0 × 10-4 mol L-1 of NMS without the needing to renew electrode surface. Results for this series of measures were calculated and standard deviation was of only 1.2%, suggesting that in these conditions the electrode showed a stable response in addition to suffer no poisoning effects. For simultaneous determination of TMP and SMX an analytical method using capillary electrophoresis with contactless conductivity detection (C4D) was developed. Using a 10 mmol L-1 lithium-phosphate (pH 7.1) solution as running buffer, a linear response range for both analytes was obtained ranging through 12.5 to 200 × 10-6 mol L-1 with R> 0.999. Under these analysis conditions, DL of 1.1 × 10-6 mol L-1 for TMP, and 3.3 × 10-6 mol L-1 for SMX were obtained, with a total analysis time of only 2.6 minutes.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2014-03-14
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.