• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Thèse de Doctorat
DOI
https://doi.org/10.11606/T.46.2017.tde-11042017-071834
Document
Auteur
Nom complet
Mauro Sergio Ferreira Santos
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2017
Directeur
Jury
Gutz, Ivano Gebhardt Rolf (Président)
Fornaro, Adalgiza
Jesus, Dosil Pereira de
Muñoz, Rodrigo Alejandro Abarza
Paixão, Thiago Regis Longo Cesar da
Titre en portugais
Eletroforese capilar com derivatização eletroquímica de compostos neutros: novas aplicações, otimização e miniaturização do sistema em fluxo EC-CE-C4D
Mots-clés en portugais
Ablação em vidro
Análise de etanol e metanol
Derivatização eletroquímica
Eletroforese capilar
Eletroforese em microchip
Eletrooxidação de glicerol
Instrumentação analítica
Laser de CO2
Miniaturização
Resumé en portugais
A combinação de célula eletroquímica (EC) com a entrada do equipamento de eletroforese capilar (CE), apesar de recente, tem permitido realizar determinação de ânions radicais; pré-concentração eletroquímica de metais pesados, seguida de redissolução, separação e detecção; bem como monitorar produtos carregados formados por oxidação eletrocatalítica de espécies neutras, como álcoois primários e glicerol. Empregando o sistema EC-CE-C4D desenvolvido pelo grupo, a determinação simultânea de cátions, ânions (no contra fluxo) e espécies neutras (detectadas após derivatização eletroquímica) foi demonstrada pela primeira vez, tendo o antisséptico bucal (Listerine® Tartar Control) como amostra real. Embora constante e reprodutível, a conversão dos álcoois primários nos respectivos carboxilatos apresentou rendimento relativamente baixo, ~16%, nas condições anteriormente adotadas, 1,6 V vs. Ag/AgClKCl 3M empregando eletrodo de platina em meio ácido (HNO3 5 mmol L-1 / HCl 1 mmol L-1). Dessa maneira, avaliou-se a oxidação de álcoois primários de cadeia normal (C2 − C5) sobre diferentes materiais de eletrodo (ouro e platina) em diferentes meios (ácido, neutro e alcalino). Os carboxilatos gerados foram monitorados injetando uma alíquota da amostra derivatizada no capilar (50 µm d.i., 45 cm de comprimento e 20 cm efetivo) aplicando 5 kPa durante 5 s, e durante as separações, 30 kV foi aplicado entre as extremidades do capilar preenchido com Tris 30 mmol L-1 / HCl 10 mmol L-1 usado como BGE. Os resultados obtidos com o sistema EC-CE-C4D apontaram maior conversão dos álcoois nos respectivos ácidos carboxílicos em meio ácido, tanto em ouro quanto em platina. Adicionalmente, em eletrodo de ouro a formação dos carboxilatos apresentou certa seletividade não observada sobre platina, favorecendo a conversão dos álcoois de cadeia menor. Noutra vertente, buscando atender as necessidades atuais por metodologias que possibilitem monitorar a eletrooxidação do glicerol em reatores eletroquímicos, desenvolveu-se um método que permitiu determinar simultaneamente o glicerol e alguns de seus possíveis produtos de oxidação neutros, como gliceraldeído e dihidroxiacetona, explorando a formação de complexo carregado com borato (presente no BGE composto por H3BO3 60 mmol L-1 / LiOH 30 mmol L-1), além dos produtos ionizáveis (ácidos carboxílicos) que são comumente analisados por CE. O equipamento de CE utilizado, munido de dois detectores C4D, também permitiu avaliar a interação de alguns ácidos carboxílicos com os modificadores de EOF, Polybrene® e CTAB, empregando MES 30 mmol L-1 / His 30 mmol L-1 como BGE. Seguindo a atual tendência à miniaturização de sistemas analíticos, avaliou-se a possibilidade de construir um sistema EC-CE-C4D miniaturizado. Para isso, um novo método para fabricação de microdispositivos em vidro, baseado em ablação a laser de CO2 assistida por parafina, como alternativa aos dispendiosos métodos de corrosão por via úmida foi desenvolvido. Os dispositivos obtidos por esse método apresentaram canais de perfil semicircular, e as dimensões puderam ser controladas variando a potência e/ou a velocidade de ablação do laser. Contudo, pelos desafios ainda encontrados para se construir um sistema EC-CE-C4D completo em substrato de vidro por ablação a laser de CO2, optou-se por iniciar a miniaturização do sistema EC-CE-C4D com um sistema híbrido em que se aproveita as características mais bem definidas e favoráveis dos tubos capilares de sílica fundida usados em CE convencional. Esse sistema permitiu a determinação quantitativa de metanol na presença de alta concentração de etanol, possibilitando, numa primeira aplicação, realizar o monitoramento da quantidade de metanol e etanol nas frações iniciais coletada durante o processo de destilação fracionada na produção de uísque de milho (moonshine) feito em laboratório. Visto a maior seletividade para conversão dos álcoois de cadeia menor obtidas em eletrodo de ouro e meio ácido, esse foi escolhido para a presente aplicação. As condições que apresentaram melhores resultados no sistema híbrido EC-CE-C4D abrangeram diluição de 100 vezes da amostra em HNO3 2 mmol L-1, eletrooxidação a 1,4 V vs. Ag durante 60 s, injeção eletrocinética no capilar mediante aplicação de 3 kV durante 4 s, e a separação dos carboxilatos realizada aplicando 3 kV entre as extremidades do capilar (50 µm d.i., 15 cm de comprimento com 12 cm efetivo), preenchido com CHES 10 mmol L-1 / NaOH 5 mmol L-1, usado como BGE. A análise das primeiras frações destiladas da "labmade moonshine" apresentou um aumento na concentração de etanol (variando de ~80 % a ~100 %) e simultâneo decréscimo da concentração de metanol (variando de 4 % a ~0,1 %). Em suma, avançou-se tanto no leque de aplicações da derivatização eletroquímica hifenizada com a eletroforese capilar como na miniaturização da instrumentação analítica para EC-CE-C4D, favorecendo a disseminação dessa poderosa combinação de três técnicas eletroquímicas.
Titre en anglais
Capillary Electrophoresis with Electrochemical Derivatization of Neutral Compounds: New Application, Optimization and Miniaturization of the Flow System EC-CE-C4D
Mots-clés en anglais
Analysis of ethanol and methanol
Analytical instrumentation
Capillary electrophoresis
CO2 laser
Electrochemical derivation
Glass ablation
Glycerol electrooxidation
Microchip electrophoresis
Miniaturization
Resumé en anglais
The direct couple of electrochemical cell (EC) with the inlet of the capillary electrophoresis (CE) equipment, recently demonstrated, has allowed the determination of radical anions; to perform electrochemical preconcentration of traces of heavy metals, followed by stripping, injection, separation and detection; and the generation of charged species by electrochemical oxidation of neutral molecules, e.g. primary alcohols and glycerol. Employing the EC-CE-C4D system developed by our group, the simultaneous determination of cations, anions (in the counter EOF mode) and neutral species (after electrochemical derivatization) was demonstrated for the first time and a mouthwash (Listerine® Tartar Control) was used as a real sample. Although constant and reproducible, the conversion of primary alcohols into carboxylates had a low yield (~16%), under the adopted conditions, 1.6 V vs. Ag/AgClKCl 3M using platinum electrode in acid medium (5 mmol L-1 HNO3 / 1 mmol L-1 HCl). Thus, the yield of carboxylates was studied for the oxidation of alcohols (C2 − C5) on two electrode materials (gold and platinum) in different media (acid, neutral and alkaline). After the electrooxidation step an aliquot of the derivatized sample was automatically injected into the capillary (50 µm i.d., 45 cm in length and 20 cm up to detector) by applying 5 kPa during 5 s. The separation was carried out applying 30 kV between the capillary ends previously filled with 30 mmol L-1 Tris / 10 mmol L-1 HCl BGE. Cyclic voltammograms show higher current density for alcohols oxidation in alkaline medium than in acid one both on gold and platinum electrodes. On the other hand the yields of carboxylic acids were higher in acidic medium. Besides that, only on gold electrode some selectivity for the carboxylate formation was observed favoring the conversion of the short chain alcohols. In order to meet the current needs for methodologies that allow the monitoring of the electrooxidation of glycerol in electrochemical reactors, a method was also developed that allowed the determination of glycerol and some of its possible neutral oxidation products, such as glyceraldehyde and dihydroxyacetone, by exploring the formation of borate complexes (provided in the BGE composed of 60 mmol L-1 H3BO3 / 30 mmol L-1 LiOH), together with ionizable ones like carboxylic acids. The employed CE equipment with two C4D detectors allowed the evaluation of the interaction between some carboxylic acids and the EOF modifiers, Polybrene® and CTAB, using 30 mmol L-1 MES / 30 mmol L-1 His as BGE. Aligned with a current trend of analytical instrumentation, the miniaturized EC-CE-C4D system was attempted. For that, a new method for manufacturing microdevices in glass, based on paraffin-assisted CO2 laser ablation, was developed as an alternative to costly wet-etching methods. The devices obtained by this method presented channels of semicircular profile and the dimensions could be controlled by varying the laser power and/or ablation velocity. Due to remaining challenges in the construction of a complete laser ablated EC-CE-C4D system on glass, a miniaturized system based on a hybrid approach is presented in the thesis, by taking advantage of the more defined and favorable characteristics of the well known fused silica capillary tubes used in CE. This system allowed the quantitative determination of methanol in the presence of high ethanol concentration by taking advantage of the higher yield of short-chain carboxylic acid formation on gold in acidic medium. The first application was the monitoring of the amount of methanol and ethanol in the initial fractions collected during the fractional distillation process in the production of corn whiskey (moonshine) made in the laboratory. The conditions that showed the best results with the hybrid EC-CE-C4D system included a 100-fold dilution of the sample in 2 mmol L-1 HNO3, electrooxidation at 1.4 V vs. Ag for 60 s, electrokinetic injection into the capillary by applying 3 kV for 4 s and separation of the carboxylates carried out under 3 kV between the ends of the capillary (50 µm i.d., 15 cm in length and 12 cm up to detector) previously filled with 10 mmol L-1 CHES / 5 mmol L-1 NaOH, used as BGE. Analysis of the first distilled fractions of labmade moonshine showed an increase in ethanol concentration (ranging from ~ 80% to ~ 100%) and a simultaneous decrease in methanol concentration (ranging from 4% to ~ 0.1%). In short, both the range of applications of electrochemical derivatization hyphenated with capillary electrophoresis as well the miniaturization of analytical instrumentation for EC-CE-C4D were improved, favoring the dissemination of this powerful combination of three electrochemical techniques.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2017-04-24
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.