• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tesis Doctoral
DOI
https://doi.org/10.11606/T.46.2016.tde-06042016-113117
Documento
Autor
Nombre completo
Luís Marcos Cerdeira Ferreira
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2015
Director
Tribunal
Angnes, Lucio (Presidente)
Bertotti, Mauro
Muñoz, Rodrigo Alejandro Abarza
Paixão, Thiago Regis Longo Cesar da
Pedrotti, Jairo Jose
Título en portugués
Caracterização e aplicação analítica de eletrodos modificados com sistemas porfirínicos supramoleculares
Palabras clave en portugués
Eletrocatálise
Eletrodos modificados
Hemoglobinas
Porfirinas tetrarrutenadas
Sensores eletroquímicos
Sistemas supramoleculares
Resumen en portugués
Estudos com eletrodos modificados foram conduzidos utilizando dois sistemas porfirínicos supramoleculares diferentes. O primeiro foi baseado na modificação de eletrodo de carbono vítreo com uma porfirina de níquel tetrarrutenada, [NiIITPyP{RuII(bipy)2Cl}4]4+. A modificação do eletrodo foi realizada por meio de sucessivos ciclos voltamétricos em meio alcalino (pH 13), gerando um eletrodo com característica similar a eletrodos modificados com α-Ni(OH)2. A caracterização química do filme formado foi realizada através das técnicas de voltametria cíclica, ressonância paramagnética eletrônica, espectroscopia eletrônica por reflectância e espectroscopia Raman com ensaio espectro-eletroquímico. Os resultados sugerem a formação de um polímero de coordenação, [µ-O2-NiIITPyP{RuII(bipy)2Cl}4]n, composto por subunidades porfirínicas ligadas entre si por pontes µ-peroxo axialmente coordenadas aos átomos de níquel (Ni-O-O-Ni). O crescimento do filme apresentou dependência da alcalinidade do meio pela formação do precursor octaédrico [Ni(OH)2TRPyP]2+ em solução, pela coordenação de OH- nas posições axiais do átomo de níquel. O processo de eletropolimerização indicou a participação de radical hidroxil, gerado por oxidação eletrocatalítica da água nos sítios periféricos da porfirina contendo o complexo de rutênio. O mesmo eletrodo foi aplicado como sensor eletroquímico para análise amperométrica de ácido fólico em comprimidos farmacêuticos. O sensor foi associado a um sistema de Batch Injection Analysis (BIA) alcançando considerável rapidez e baixo limite de detecção. Para as análises das amostras também foi proposto um método para a remoção da lactose, que agia como interferente. O segundo estudo envolveu a modificação de eletrodos de carbono vítreo com diferentes hemoglobinas, naturais (HbA0, HbA2 e HbS) e sintéticas (Hb-PEG5K2, αα-Hb-PEG5K2 e BT-PEG5K4), para a avaliação da eficiência na redução eletrocatalítica de nitrito mediada por FeI-heme. Os filmes foram produzidos pela mistura de soluções das hemoglobinas com brometo de didodecildimetiltrimetilamônio (DDAB), aplicados nas superfícies com consecutiva evaporação, formando filmes estáveis. Os valores de potencial redox para os processos do grupo heme e a sua associação com a disponibilidade do grupo na proteína foram avaliados por voltametria cíclica. Os valores das constantes de velocidade, k, para redução de nitrito foram obtidos por cronoamperometria em -1,1 V (vs Ag/AgCl(KCl 3M)) que foram utilizados para estudo comparativo entre as espécies sintéticas para eventual aplicação clínica.
Título en inglés
Characterization and analytical application of electrodes modified with supramolecular pophyrin sytems.
Palabras clave en inglés
Electrocatalysis
Electrochemical sensors
Hemoglobin
Modified electrodes
Supramolecular systems
Tetraruthenated porphyrins
Resumen en inglés
Studies with modified electrodos were conducted using two different supramolecular porphyrin systems. The first one was based on the modification of glassy carbon electrode with a tetraruthenated nickel porphyrin, [NiIITPyP{RuII(bipy)2Cl}4]4+. The electrode modification was carried out through successive voltemmetric cycles in alkaline media (pH 13), generating an electrode with feature similar to α-Ni(OH)2 modified electrodes. The chemical characterization of this film was performed by cyclic voltammetry, electronic paramagnetic resonance, reflectance electronic spectroscopy and Raman spectroscopy with spectroelectrochemistry assay. The results suggested the formation of a coordination polymer, [µ-O2-NiIITPyP{RuII(bipy)2Cl}4]n, composed by porphyrin subunits linked by µ-peroxo bridges axially coordinated to nickel atoms (Ni-O-O-Ni). The film growth showed dependence of the alkaline media by the formation of octahedral precursor [Ni(OH)2TRPyP]2+ in solution by way of axial coordination of OH- to the nickel atoms. The electropolymerization process showed to have a contribution from hydroxyl radicals, generated by electrocatalytic oxidation of water on the peripheral sites containing the ruthenium complexes. The same electrode was applied as an electrochemical sensor for amperometric analysis of folic acid in pharmaceutical tablets. The sensor was associated to a Bath Injection Analysis (BIA) system, achieving good sampling frequency and low detection limit. For the samples analysis, it was also proposed a method for lactose removal. The second study comprises the modification of glassy carbon electrodes with different hemoglobin species, of natural occurrence (HbA0, HbA2 e HbS) and synthetics (Hb-PEG5K2, αα-Hb-PEG5K2 e BT-PEG5K4) for evaluation of efficiency on electrocatalytic reduction of nitrite mediated by FeI-heme. The films were produced by mixing solutions of the hemoglobins with didecyldimethylammonium bromide (DDAB), applied on the surfaces with following solvent evaporation, forming stable films. The redox potential values for the heme group processes and the heme availability in the protein were evaluated by cyclic voltammetry. The reaction rate constants, k, for nitrite reduction were obtained by chronoamperometry at -1,1 V, which were used for comparative study between the synthetic species for further clinical applications.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2016-05-19
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.