Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.46.2006.tde-24112006-154234
Document
Auteur
Nom complet
Allan Cezar Vieira dos Santos
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2006
Directeur
Jury
Masini, Jorge César (Président)
Abate, Gilberto
Rocha, Fábio Rodrigo Piovezani
Titre en portugais
Uso de técnicas eletroanalíticas em fluxo no estudo da adsorção de Cd(II), Pb(II) e Cu(II) em vermiculita visando tratamento alternativo para efluentes da indústria de tintas
Mots-clés en portugais
Análise por injeção seqüencial
Eletroanalítica
Metais pesados
Resíduos industriais
Tratamento de água
Resumé en portugais
Esta dissertação descreve o uso de técnicas eletroanalíticas em fluxo no estudo da adsorção de Cd(II), Pb(II) e Cu(II) em vermiculita visando tratamento alternativo para efluentes da indústria de tintas. O estudo indicou que na faixa de pH entre 4 e 6 não há diferença entre a utilização de vermiculita expandida ou não-expandida na remoção dos íons. Observou-se que nos pH's avaliados o tempo de interação de 180 minutos foi suficiente para que o sistema atingisse o equilíbrio. Pode-se afirmar que a vermiculita não expandida apresenta as seguintes ordens de afinidade pelo cátions considerados: pH 4: Cu(II) < Cd(II) < Pb(II); pH 5: Cu(II) ? Cd(II) < Pb(II); pH 6: Cd(II) < Cu(II) < Pb(II). Nas condições de trabalho, os ensaios envolvendo a coluna de vermiculita não evidenciaram uma melhor capacidade de extração dos íons estudados frente ao sistema de extração em batelada. Percentuais de extração da ordem de 76% em amostra de efluente no sistema em batelada reforçam a viabilidade do uso da vermiculita como adsorvente destes metais. Um método SIA-ASV (análise por injeção seqüencial - voltametria de redissolução anódica) foi proposto e validado. Para um tempo de deposição de 80 s e vazão de 10 µLs-1, os limites de detecção foram 0,06, 0,09 e 0,16 µmolL-1 para Cd, Pb e Cu, respectivamente, além de apresentar uma faixa linear de trabalho entre 0,2 e 9,0 µmolL-1.
Titre en anglais
Use of flow electroanalytical techniques to study the adsorption of Cd(II), Pb(II) and Cu(II) onto vermiculite aiming an alternative treatment of wastewater from coatings industry
Mots-clés en anglais
Electroanalysis
Heavy metals
Industrial wastes
Sequential injection analysis
Wastewater treatment
Resumé en anglais
This dissertation describes the use of flow electroanalytical techniques to study the adsorption of Cd(II), Pb(II) and Cu(II) onto vermiculite aiming an alternative treatment of wastewater from coatings industry. The study indicated that under pH range from 4 to 6 there is no difference on using expanded or not expanded vermiculite for removal of ions. It was also observed that at any evaluated pH, a 180 minutes interaction time was long enough to allow the system reach equilibrium. It's possible to state that non-expanded vermiculite presents the following affinity orders by the studied ions: pH 4: Cu(II) < Cd(II) < Pb(II); pH 5: Cu(II) ? Cd(II) < Pb(II); pH 6: Cd(II) < Cu(II) < Pb(II). At working conditions, tests involving vermiculite columns didn't show a better performance on extracting these ions when faced to batch extraction systems. Extraction percentuals of about 76% were obtained using a sample of coatings industry wastewater, reinforcing the viability of the use of vermiculite as an adsorbent of these metals. A SIA-ASV (sequential injection analysis - anodic stripping voltammetry) method was proposed and validated. For a deposition time of 80 s and a flow rate of 10 µL s-1, detection limits were 0.06, 0.09 and 0.16 µmol L-1 to Cd, Pb and Cu, respectively; a linear working range, between 0.2 and 9.0 µmol L-1 was also determined.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2007-03-22
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.