• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.46.2006.tde-24112006-154234
Documento
Autor
Nombre completo
Allan Cezar Vieira dos Santos
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2006
Director
Tribunal
Masini, Jorge César (Presidente)
Abate, Gilberto
Rocha, Fábio Rodrigo Piovezani
Título en portugués
Uso de técnicas eletroanalíticas em fluxo no estudo da adsorção de Cd(II), Pb(II) e Cu(II) em vermiculita visando tratamento alternativo para efluentes da indústria de tintas
Palabras clave en portugués
Análise por injeção seqüencial
Eletroanalítica
Metais pesados
Resíduos industriais
Tratamento de água
Resumen en portugués
Esta dissertação descreve o uso de técnicas eletroanalíticas em fluxo no estudo da adsorção de Cd(II), Pb(II) e Cu(II) em vermiculita visando tratamento alternativo para efluentes da indústria de tintas. O estudo indicou que na faixa de pH entre 4 e 6 não há diferença entre a utilização de vermiculita expandida ou não-expandida na remoção dos íons. Observou-se que nos pH's avaliados o tempo de interação de 180 minutos foi suficiente para que o sistema atingisse o equilíbrio. Pode-se afirmar que a vermiculita não expandida apresenta as seguintes ordens de afinidade pelo cátions considerados: pH 4: Cu(II) < Cd(II) < Pb(II); pH 5: Cu(II) ? Cd(II) < Pb(II); pH 6: Cd(II) < Cu(II) < Pb(II). Nas condições de trabalho, os ensaios envolvendo a coluna de vermiculita não evidenciaram uma melhor capacidade de extração dos íons estudados frente ao sistema de extração em batelada. Percentuais de extração da ordem de 76% em amostra de efluente no sistema em batelada reforçam a viabilidade do uso da vermiculita como adsorvente destes metais. Um método SIA-ASV (análise por injeção seqüencial - voltametria de redissolução anódica) foi proposto e validado. Para um tempo de deposição de 80 s e vazão de 10 µLs-1, os limites de detecção foram 0,06, 0,09 e 0,16 µmolL-1 para Cd, Pb e Cu, respectivamente, além de apresentar uma faixa linear de trabalho entre 0,2 e 9,0 µmolL-1.
Título en inglés
Use of flow electroanalytical techniques to study the adsorption of Cd(II), Pb(II) and Cu(II) onto vermiculite aiming an alternative treatment of wastewater from coatings industry
Palabras clave en inglés
Electroanalysis
Heavy metals
Industrial wastes
Sequential injection analysis
Wastewater treatment
Resumen en inglés
This dissertation describes the use of flow electroanalytical techniques to study the adsorption of Cd(II), Pb(II) and Cu(II) onto vermiculite aiming an alternative treatment of wastewater from coatings industry. The study indicated that under pH range from 4 to 6 there is no difference on using expanded or not expanded vermiculite for removal of ions. It was also observed that at any evaluated pH, a 180 minutes interaction time was long enough to allow the system reach equilibrium. It's possible to state that non-expanded vermiculite presents the following affinity orders by the studied ions: pH 4: Cu(II) < Cd(II) < Pb(II); pH 5: Cu(II) ? Cd(II) < Pb(II); pH 6: Cd(II) < Cu(II) < Pb(II). At working conditions, tests involving vermiculite columns didn't show a better performance on extracting these ions when faced to batch extraction systems. Extraction percentuals of about 76% were obtained using a sample of coatings industry wastewater, reinforcing the viability of the use of vermiculite as an adsorbent of these metals. A SIA-ASV (sequential injection analysis - anodic stripping voltammetry) method was proposed and validated. For a deposition time of 80 s and a flow rate of 10 µL s-1, detection limits were 0.06, 0.09 and 0.16 µmol L-1 to Cd, Pb and Cu, respectively; a linear working range, between 0.2 and 9.0 µmol L-1 was also determined.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2007-03-22
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.