• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.46.2006.tde-23032007-182139
Document
Author
Full name
Thiago Nogueira
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2006
Supervisor
Committee
Lago, Claudimir Lúcio do (President)
Oliveira, Marcone Augusto Leal de
Tavares, Marina Franco Maggi
Title in Portuguese
Determinação de cafeína e identificação de adulterações no café empregando a eletroforese capilar com detecção condutométrica sem contato
Keywords in Portuguese
Café
Cafeína
Detecção condutométrica sem contato
Eletroforese
Glucose
Xilose
Abstract in Portuguese
Neste trabalho foram desenvolvidas estratégias para a determinação de cafeína e detecção de adulterações no café, empregando a eletroforese capilar com detecção condutométrica sem contato (CE-C4D). A estratégia desenvolvida para a separação da cafeína se baseia na complexação dinâmica do analito com o ânion do eletrólito de corrida, 3,4-dimetoxicinamato. Utilizou-se como eletrólito de corrida 20 mmol L-1 de ácido 3,4-dimetoxicinâmico/Tris (pH 8,5). As separações foram conduzidas contra o fluxo eletrosmótico e o tempo de análise foi menor do que 5 minutos. Adicionalmente, o método se mostrou seletivo uma vez que análogos da cafeína (teobromina e teofilina) apresentaram tempo de migração diferenciado. O método proposto foi comparado com uma metodologia padrão (HPLC), apresentando resultados concordantes. O método foi aplicado para a determinação de cafeína em amostras de café convencional, solúvel e descafeinado. O limite de quantificação estimado para o método (0,33 mg/g) se mostrou suficientemente baixo, de forma a atender às exigências da legislação vigente. A identificação de adulterações no café provenientes da adição de outros materiais pode ser procedida utilizando como indicadores os teores totais de glicose e xilose obtidas por hidrólise controlada. Para promover a separação dessas espécies dos demais carboidratos presentes no café, varias estratégias foram avaliadas. As separações foram realizadas utilizando NaOH como eletrólito de corrida, de forma a possibilitar a ionização dessas espécies. O emprego de aditivos como metanol, acetonitrila e íons borato foram avaliados. A melhor condição obtida foi utilizando 80 mmol L-1 de NaOH, 0,5 mmol L-1 CTAB e 30% (v/v) de metanol. Os resultados mostraram que é possível identificar contaminações menores que aquelas consideradas como limites aceitáveis.
Title in English
Determination of caffeine and identification of adulteration in coffee by capillary electrophoresis with capacitively coupled contactless conductivity detection
Keywords in English
Caffeine
Capacitively coupled contactless conductivity detection
Coffee
Electrophoresis
Glucose
Xylose
Abstract in English
In this work, methods based on capillary electrophoresis with capacitively coupled contactless conductivity detection (CE-C4D) for the determination of caffeine in coffee as well as for the identification of its adulteration by addition of some other vegetal products were developed. Caffeine is a neutral species, and the proposed method was based on its mobilization by the formation of a complex with the anion 3,4 dimethoxycinnamate. The experiments were carried out in buffer Tris/3,4 dimethoxycinnamic acid (pH 8.5) and the migration of the complex was done in counter electroosmotic flow. The running time was less than 5 minutes. In addition, theobromine and theophylline (two caffeine analogues) were completely separated. The new method was compared to a standard method based on HPLC, and similar results were obtained. Samples of integral, soluble, and decaffeinated coffees were analyzed and the limit of quantification (0.33 mg/g) was low enough to fulfill the Brazilian norm. The proposed approach for the identification of adulteration was based on the controlled hydrolysis of xylan and starch present in some vegetable adulterants, followed by the analysis of the resulting xylose and glucose, which are the monosaccharides that compose, respectively, the two polysaccharides. Although the monosaccharides are neutral species in ordinary conditions, they form anionic species in high values of pH. The best separations were obtained in NaOH 80 mmol L-1, CTAB 0.5 mmol L-1, and methanol 30% (v/v). The results showed that it is possible to identify levels of contamination below tolerable limits.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Thiago_dissertacao.pdf (897.30 Kbytes)
Publishing Date
2007-08-01
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.