Disertación de Maestría
DOI
https://doi.org/10.11606/D.46.2007.tde-19102007-105035
Documento
Autor
Nombre completo
Alexandre Luiz de Souza
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2007
Director
Tribunal
Oliveira, Pedro Vitoriano de (Presidente)
Gomes Neto, José Anchieta
Rocha, Fabio Rodrigo Piovezani
Título en portugués
Determinação simultânia de Cd/Pb em cimento usando TI como padrão interno e de Cr/Mn em alumina por espectrometria de absorção atômica com amostragem de suspensão
Palabras clave en portugués
Alumina
Cimento
Espectrometria de absorção atômica
Resumen en portugués
O objetivo desse trabalho foi o desenvolvimento de métodos analíticos para a determinação simultânea de Cd/Pb em cimento e Cr/Mn em alumina por espectrometria de absorção atômica com atomização eletrotérmica (SIMAAS) e amostragem de suspensão. Considerando os erros de amostragem de suspensão e as condições compromissadas impostas para a determinação simultânea, foi também objetivo do trabalho estudar a aplicação de padrão interno para corrigir erros sistemático e aleatório. A viabilidade de se usar o Tl como padrão interno foi explorada na determinação de Cd e Pb em cimento. O uso do padrão interno se baseou na hipótese de que o elemento Tl deveria adsorver quantitativamente sobre as partículas do material em suspensão. Foi feito o estudo térmico dos elementos Cd, Pb e Tl em soluções aquosas e suspensões, na presença e ausência de diferentes modificadores químicos. O melhor modificador químico (5 µg Pd + 3 µg Mg) foi escolhido com base nos gráficos de correlação. As melhores temperaturas de pirólise e atomização para a determinação simultânea de Cd e Pb foram 600°C e 2000°C, respectivamente. A preparação das amostras foi feita com suspensões contendo 30 µg L-1 de Tl em 0,1 % (v v-1) de HNO3 + 0,025 % (m v-1) de Triton X-100. A avaliação da exatidão foi feita com a determinação de Cd e Pb em cimento de construção civil e dentário com análise de solução e análise de materiais de referência de sedimento marinho (MESS1 e BCSS 1) e de rio (Buffalo River, IEAEA 356). Os resultados foram concordantes em um nível de confiança de 95% (teste t-student). Os limites de detecção (LD) obtidos foram 0,14 µg L-1 (1,4pg) para o Cd e de 1,2 µg L-1 (12 pg) para Pb. As massas características foram 1,2 pg e 25 pg para Cd e Pb, respectivamente. Na determinação simultânea de Cr e Mn em alumina não foi utilizado padrão interno. O estudo envolveu a obtenção de curvas de pirólise e atomização em presença de diferentes modificadores. Estudos de interferência mostraram que 100 mg L-1 de Al provocaram aumento nos sinais analíticos dos elementos que foi eliminado com o modificador químico NaOH (0,2 mol L-1) + HF (0,4 mol L-1) combinado com 350 µg de Nb. Nessa condição as temperaturas de pirólise e atomização foram 1400°C e 2400°C, respectivamente. As suspensões de alumina foram preparadas em 2 % (v v-1) HNO3. A avaliação da exatidão foi feita com a determinação de Cr e Mn em material de referência de alumina (Alumina Reduction Grade - 699) e os resultados foram concordantes em um nível de confiança de 95% (teste t-student). Os limites de detecção (LD), estimados a partir da variabilidade de 20 medidas consecutivas de uma solução contendo 2 % (v v-1) HNO3 foram 0,11 µg L-1 (2,2 pg) para Cr e 0,17 µg L-1 (3,5 pg) para o Mn. As massas características foram 10 pg e 1,3 pg para Cr e Mn, respectivamente.
Título en inglés
Simultaneous determination of Cd/Pb in cement using Tl as internal standard and Cr/Mn in alumina by atomic absorption spectrometry with slurry sampling
Palabras clave en inglés
Alumina
Atomic absorption spectrometry
Cement
Resumen en inglés
The aim of this work was the development of analytical methods for the simultaneous determination of Cd/Pb in cement and Cr/Mn in alumina by electrothermal atomic absorption spectrometry (SIMAAS) and slurry sampling. Considering the errors of slurry sampling and the imposed compromissed conditions for the simultaneous determination, it was also the aiming of this work to study the application of internal standard for the sistematic and random errors correction. The viability of using Tl as internal standard was investigated for Cd and Pb determination in cement. The internal standard aplicability was based on the hypothesis of the element Tl would have to adsorver quantitatively on the particles of the material in suspension. The thermal behaviour of Cd, Pb and Tl in aqueous solutions and suspensions was obtained in presence and absence of different chemical modifiers. The best chemical modifier (5 mg Pd + 3 mg Mg) was chosen based on correlation graphs. The pyrolysis and atomization temperatures for the simultaneous determination of Pb were 600°C and 2000°C, respectively. The sample the preparation was made with 30 mg L-1 of Tl in 0,1% (v v-1) of HNO3 + 0.025% (m v-1 of Triton X-100. The evaluation of the accuracy was made with the determination of Cd and Pb in cement, microwave extraction in acid media and analysis of marine sediment reference materials (MESS1 and BCSS 1) and river sediment (Buffalo River, IEAEA 356). The results are concordant at 95% of confidence level using Studen's t-test. The detention limits (LD) was 0.14 µg L-1 (1.4 pg) for Cd and 1.2 µg L-1(12 pg) for Pb. The characteristic masses were 1.2 pg and 25 pg for Cd and Pb, respectively. The simultaneous determination of Cr and Mn in alumina was done without internal standard. Pyrolysis and atomization temperaturas were obtained in presence of different modifiers. Studies of interference shown that 100 mg L-1 of Al provoked increase in the analytical signals of Cr and Mn that was eliminated with the chemical modifier NaOH (0,2 mol L-1) + HF (0,4 mol L-1) combined with 350 mg of Nb as permanent chemical modifier. In this condition pyrolysis and atomization temperatures were 1400 °C and 2400 °C, respectively. The alumina suspensions were prepared in 2% (v v-1) HNO3. The evaluation of the accuracy was made with the determination of Cr and Mn in alumina reference material (Reduction Alumina Grating - 699) and the results were concordant at 95 % of the confidence level using Student's t-test. The detention limits (LD) were 0.11 µg L-1 (2.2 pg) for Cr and 0.17 µg L-1 (3.5 pg) for Mn. The characteristic masses were 10 and 1.3 pg for Cr and Mn, respectively.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2007-11-01
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.