• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.46.2007.tde-18102007-164848
Document
Auteur
Nom complet
Robson Pinho da Silva
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2007
Directeur
Jury
Serrano, Silvia Helena Pires (Président)
Bertotti, Mauro
Fatibello Filho, Orlando
Titre en portugais
Aplicações analíticas de eletrodos quimicamente modificados por espécies de interesse biológico
Mots-clés en portugais
Ácido úrico
Dopamina
Eletrodo modificado
Guanina
NADH
Voltametria
Resumé en portugais
O trabalho apresentado nesta Dissertação de Mestrado descreve o desenvolvimento e aplicação de eletrodos de pasta de carbono modificados eletroquimicamente em soluções de guanina e de eletrodos de grafite pirolítico modificados em soluções de dopamina. Estes eletrodos foram empregados na detecção e, a quantificação, por voltametria de pulso diferencial (VPD), de alguns compostos de importância biológicas tais como NADH, NADPH, 8-oxo-guanina, ácido úrico (AU), ácido ascórbico (AA), dopamina (DA) e xantina (XA). No primeiro caso, os eletrodos de pasta de carbono foram modificados em solução de guanina por aplicação de um potencial de 1,1 V (vs Ag/AgCl, KClsat) ao eletrodo de trabalho por 12 minutos sob sat agitação constante. Com estes eletrodos detectaram-se NADH, NADPH, 8-oxo-guanina e AU, com limites de detecção de 3,3, 3,7, 2,0 e 6,6 x 10-6 mol L-1 respectivamente, na faixa de concentração de 7,5 x 10-6 a 8,1 x 10-4 mol L-1 . No segundo caso, eletrodos de grafite pirolítico, previamente tratados em solução de NaOH, foram modificados eletroquimicamente em solução de DA por aplicação de um potencial 1,5 V (vs Ag/AgCl, KClsat ) ao eletrodo de trabalho durante 2 minutos. Com estes eletrodos foi possível a determinação simultânea de AA, AU e DA. Para obtenção das curvas analíticas variou- se a concentração do analito de interesse, mantendo-se constante a concentração dos possíveis interferentes nos valores de 1,0 x 10-4 mol L-1 (DA), 5,0 x 10-5 mol L-1 (AU) e 1,0 x 10-3 mol L-1 (AA). Os limites de detecção calculados para AU, AA e DA foram respectivamente de 1,4 x 10-6 mol l-1 , 2,5 x 10-5 mol l-1 e 1,1 x 10-7 mol l-1 . Ácido úrico foi determinado em amostras de urina, sangue e soro humano com 92 a 103 % de recuperação, sem a necessidade de tratamento prévio das amostras.
Titre en anglais
Analytical applications of chemically modified electrode of biological species interest
Mots-clés en anglais
Dopamine
Guanine
Modified electrode
NADH
Uric acid
Voltammetry
Resumé en anglais
Chemically Modified Carbon Paste and Pyrolitic Graphite Electrodes were prepared via electrochemical deposition from guanine and dopamine solutions. Carbon paste electrodes were modified in guanine solutions under an applied potential of 1.1 V (vs Ag/AgCl, KClsat ) during 12 minutes under constant stirring. They were used for sat electrochemical detection of NADH, NADPH, uric acid and 8-oxoguanine. Detection limits were 3.3, 3.7, 6.6 and 2.0 10-6 mol L-1 respectively, with sensitivity of 0.13, 0.10, 0.26 and 0.40 A mol-1 L cm-2 , respectively. The electrodes showed high reproducibility and absence of surface poisoning effects. Good analytical performance was attributed to the formation of superficial dimer or trimers species of guanine during the modification process. Pyrolitic graphite electrodes, previously submitted an electrochemical treatment in NaOH solution, were modified in dopamine solution (phosphate buffer, pH 10) under an applied potential of 1.5 V (vs Ag/AgCl, KClsat ) during 2 minutes under constant sat stirring and, further used for the simultaneous determination of ascorbic acid (AA), uric acid (AU) and dopamine (DA). The analytical curves were obtained changing the concentration of the wished analyte, at constant concentration levels of the interferences: 1.0 x 10-4 mol L-1 (DA), 5.0 x 10-5 mol L-1 (UA) and 1.0 x 10-3 mol L-1 (AA). Detection limits were 1.4 x 10-6 mol L-1 , 2.5 x 10-5 mol L-1 and 1.1 x 10-7 mol L-1 for UA, AA and DA, respectively. Uric acid was determined in human urine, blood and serum samples without any previous treatment. Recovering percentages of 92 to 103 % were obtained.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
ErrataRobsonPinho.pdf (29.74 Kbytes)
MESTRADOROBSONPINHO.pdf (527.11 Kbytes)
Date de Publication
2007-11-01
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.