DOI
https://doi.org/10.11606/D.46.2007.tde-18102007-164848
Documento
Autor
Nombre completo
Robson Pinho da Silva
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2007
Director
Tribunal
Serrano, Silvia Helena Pires (Presidente)
Bertotti, Mauro
Fatibello Filho, Orlando
Título en portugués
Aplicações analíticas de eletrodos quimicamente modificados por espécies de interesse biológico
Palabras clave en portugués
Ácido úrico
Dopamina
Eletrodo modificado
Guanina
NADH
Voltametria
Resumen en portugués
O trabalho apresentado nesta Dissertação de Mestrado descreve o desenvolvimento e aplicação de eletrodos de pasta de carbono modificados eletroquimicamente em soluções de guanina e de eletrodos de grafite pirolítico modificados em soluções de dopamina. Estes eletrodos foram empregados na detecção e, a quantificação, por voltametria de pulso diferencial (VPD), de alguns compostos de importância biológicas tais como NADH, NADPH, 8-oxo-guanina, ácido úrico (AU), ácido ascórbico (AA), dopamina (DA) e xantina (XA). No primeiro caso, os eletrodos de pasta de carbono foram modificados em solução de guanina por aplicação de um potencial de 1,1 V (vs Ag/AgCl, KClsat) ao eletrodo de trabalho por 12 minutos sob sat agitação constante. Com estes eletrodos detectaram-se NADH, NADPH, 8-oxo-guanina e AU, com limites de detecção de 3,3, 3,7, 2,0 e 6,6 x 10-6 mol L-1 respectivamente, na faixa de concentração de 7,5 x 10-6 a 8,1 x 10-4 mol L-1 . No segundo caso, eletrodos de grafite pirolítico, previamente tratados em solução de NaOH, foram modificados eletroquimicamente em solução de DA por aplicação de um potencial 1,5 V (vs Ag/AgCl, KClsat ) ao eletrodo de trabalho durante 2 minutos. Com estes eletrodos foi possível a determinação simultânea de AA, AU e DA. Para obtenção das curvas analíticas variou- se a concentração do analito de interesse, mantendo-se constante a concentração dos possíveis interferentes nos valores de 1,0 x 10-4 mol L-1 (DA), 5,0 x 10-5 mol L-1 (AU) e 1,0 x 10-3 mol L-1 (AA). Os limites de detecção calculados para AU, AA e DA foram respectivamente de 1,4 x 10-6 mol l-1 , 2,5 x 10-5 mol l-1 e 1,1 x 10-7 mol l-1 . Ácido úrico foi determinado em amostras de urina, sangue e soro humano com 92 a 103 % de recuperação, sem a necessidade de tratamento prévio das amostras.
Título en inglés
Analytical applications of chemically modified electrode of biological species interest
Palabras clave en inglés
Dopamine
Guanine
Modified electrode
NADH
Uric acid
Voltammetry
Resumen en inglés
Chemically Modified Carbon Paste and Pyrolitic Graphite Electrodes were prepared via electrochemical deposition from guanine and dopamine solutions. Carbon paste electrodes were modified in guanine solutions under an applied potential of 1.1 V (vs Ag/AgCl, KClsat ) during 12 minutes under constant stirring. They were used for sat electrochemical detection of NADH, NADPH, uric acid and 8-oxoguanine. Detection limits were 3.3, 3.7, 6.6 and 2.0 10-6 mol L-1 respectively, with sensitivity of 0.13, 0.10, 0.26 and 0.40 A mol-1 L cm-2 , respectively. The electrodes showed high reproducibility and absence of surface poisoning effects. Good analytical performance was attributed to the formation of superficial dimer or trimers species of guanine during the modification process. Pyrolitic graphite electrodes, previously submitted an electrochemical treatment in NaOH solution, were modified in dopamine solution (phosphate buffer, pH 10) under an applied potential of 1.5 V (vs Ag/AgCl, KClsat ) during 2 minutes under constant sat stirring and, further used for the simultaneous determination of ascorbic acid (AA), uric acid (AU) and dopamine (DA). The analytical curves were obtained changing the concentration of the wished analyte, at constant concentration levels of the interferences: 1.0 x 10-4 mol L-1 (DA), 5.0 x 10-5 mol L-1 (UA) and 1.0 x 10-3 mol L-1 (AA). Detection limits were 1.4 x 10-6 mol L-1 , 2.5 x 10-5 mol L-1 and 1.1 x 10-7 mol L-1 for UA, AA and DA, respectively. Uric acid was determined in human urine, blood and serum samples without any previous treatment. Recovering percentages of 92 to 103 % were obtained.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
ErrataRobsonPinho.pdf (29.74 Kbytes)
MESTRADOROBSONPINHO.pdf (527.11 Kbytes)
Fecha de Publicación
2007-11-01
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.