• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Doctoral Thesis
DOI
https://doi.org/10.11606/T.46.2018.tde-16022018-165844
Document
Author
Full name
Marcelo Solitrenick Pinto Silva
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2003
Supervisor
Committee
Masini, Jorge Cesar (President)
Pedrotti, Jairo Jose
Reis, Boaventura Freire dos
Rocha, Fabio Rodrigo Piovezani
Rohwedder, Jarbas José Rodrigues
Title in Portuguese
Procedimentos de análise por injeção sequencial para determinação espectrofotométrica de sulfeto em amostras ambientais explorando a formação do azul de metileno
Keywords in Portuguese
Águas naturais
Águas residuárias (Análise)
Análise por injeção sequencial
Azul de metileno
Espectrofotometria
Química ambiental
Química analítica
Sedimento
SIA
Sulfeto
Abstract in Portuguese
Esta tese demonstra a aplicação da análise por injeção seqüencial (SIA) para determinação de sulfeto utilizando a química da formação do azul de metileno, a qual se baseia em dois reagentes: solução de cloridrato de dimetil p-fenileno diamina (DMPD) 3,63 mmol L-1 em meio de HCI 1,1 mol L-1 e solução de cloreto de ferro (III) 19 mmol L-1, também em meio de HCI 1, 1 mol L-1. Estas soluções foram aspiradas para dentro de uma bobina coletora do sistema SIA como duas zonas de reagente, entre as quais aspirava-se a solução da amostra. Em condições otimizadas o limite de detecção foi calculado em 40 µg L-1 de S2-, com uma faixa dinâmica de resposta linear entre 0,05 e 2,0 mg L-1 . Esta faixa linear pode ser ampliada até 32 mg L-1 utilizando-se uma etapa de diluição in-line para concentrações maiores do que 2,0 mg L-1 de S2- . As características de robustez do sistema SIA que utiliza uma bomba de pistão, confere alta estabilidade para as curvas analíticas (precisão de 4%), minimizando a trabalhosa preparação de padrões de S2-. O método foi aplicado na determinação de sulfeto volatilizável por ácidos (AVS) em sedimentos coletados em reservatórios da região metropolitana de São Paulo (RMSP) e no reservatório de Barra Bonita no rio Tietê, localizado 270 km a jusante em relação à cidade de São Paulo. As concentrações de AVS foram 9 a 14 mg kg-1 nos sedimentos de Barra Bonita e entre 1,2 e 14 g kg-1 nos sedimentos dos reservatórios Billings, Pirapora e Rasgão. Esta tese também descreve o acoplamento da análise por injeção seqüencial com análise por fluxo monossegmentado (SI-MSFA) para determinação de sulfeto em níveis de concentração típicos de águas residuais. As curvas analíticas foram construídas por diluição in-line de uma única solução padrão. A robustez do método proposto foi verificada construindo-se curvas analíticas em diferentes dias de trabalho e comparando-se os coeficientes angulares, os quais apresentaram um desvio padrão relativo de 5,2% (n=5) para uma faixa de concentração entre 0,17 e 1,0 mg L-1 de S2-. A freqüência de amostragem foi de 38 análises por hora, com um limite de detecção de 40 µg L-1. A adequabilidade do método SI-MSFA para realizar adições de padrão para determinação de S2- também foi descrita. Amostras simuladas foram analisadas pelo método proposto, apresentando taxas de recuperação entre 70 e 115%, demonstrando a adequabilidade do método SI-MSFA para realizar análise in-situ de S2- em estações automáticas de monitoramento.
Title in English
Sequential injection analysis procedure for spectrophotometric determination of sulfide in environmental samples by exploring the formation of methylene blue
Keywords in English
Analytical chemistry
Environmental chemistry
Methylene blue
Natural waters
Sediment
Sequence injection analysis
SIA
Spectrophotometry
Sulfide
Wastewater (Analysis)
Abstract in English
This thesis demonstrates the application of sequential injection analysis (SIA) to perform sulfide determination using the methylene blue chemistry, based on two reagents: 3.63 mmol L-1 N,N dimethyl-p-phenylene diamine hydrochloride in 1.1 mol L-1 HCI solution and 19 mmol L-1 FeCl3, also in 1.1 mol L-1 HCI. These solutions are aspirated inside the holding coil of the sequential injection system as two reagent zones sandwiching the sample zone. Under optimized conditions, the detection limit was calculated at 40 µg L-1 S2-, with a linear dynamic range from 0.05 to 2 mg L-1 S2-. This linear range can be extended up to 32 mg L-1 using in-line dilution for sulfide concentrations greater than 2 mg L-1. The robust characteristic of the SI system with syringe pump leads to very stable analytical curves (precision of 4%), minimizing the laborious preparation of sulfide standards. The method was applied in the determination of acid volatile sulfide in river sediments collected at the Metropolitan Area of São Paulo (MASP) City and at the Barra Bonita reservoir, located in the Tietê River, 270 km down river from São Paulo City. The concentrations of acid volatile sulfide were 9 to 14 mg kg-1 in the Barra reservoir and between 1.2 and 14 g kg-1 in sediments from Billings, Pirapora and Rasgão reservoirs. This thesis also describes the coupling of Sequential Injection with Monosegmented Flow Analysis (SI-MSFA) for determination of sulfide at typical concentrations in wastewaters. The analytical curves were constructed by in-line dilution of a single stock standard solution. The robustness of the proposed method was checked constructing analytical curves in different working days and comparing the slopes, which had a relative standard deviation of 5.2 % (n = 5) for a concentration window inside the monosegment between 0.17 and 1.0 mg L-1 S2-. The analytical throughput was 38 samples per hour and the limit of detection was 40 µg L-1. The feasibility of the SI-MSFA approach to perform standard additions for S2- determination was also described. Simulated samples analyzed by the proposed method showed recoveries between 70 and 115%, demonstrating the feasibility of the SI-MSFA method to perform in-situ analysis of S2- in automatic monitoring stations.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2018-02-16
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.