• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.46.2018.tde-15022018-113536
Documento
Autor
Nombre completo
Tan Chun Shan
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2002
Director
Tribunal
Oliveira, Elisabeth de (Presidente)
Krug, Francisco Jose
Rocha, Fabio Rodrigo Piovezani
Título en portugués
Uso de microfrascos de digestão em forno de microondas focalizadas como uma alternativa para a preparação de amostras
Palabras clave en portugués
Absorção (Análise química)
Absorção atômica
Amostragem experimental (Análise química)
Análise elementar em cabelos
FAAS
Microondas focalizadas
Preparação de amostras
Resumen en portugués
Este trabalho propõe o uso de microfrascos de polipropileno adaptados a um forno de microondas focalizadas como um procedimento alternativo para a preparação de amostras. O pré-tratamento de amostras em microfrascos digestores agrega algumas características importantes como aumento da freqüência analítica, pequena massa de amostra e baixo consumo de reagentes. A eficiência do sistema de digestão foi verificada com o desenvolvimento de metodologia para a determinação de cobre, ferro, manganês, selênio e zinco em cabelo por espectrometria de absorção atômica com atomização por chama ou eletrotérmica em forno de grafite. Os elementos selecionados são essenciais para os seres humanos e são indicadores nutricionais e do bom funcionamento enzimático. O sistema de digestão é constituído de um forno de microondas focalizadas e um tubo de vidro com 30 cm de comprimento e 4 cm de largura, ao qual são colocados quatro ou cinco microfrascos de polipropileno com capacidade para respectivamente 4,0 mL e 2,0 mL. Esses microfrascos foram adaptados a um suporte de Teflon® e fixado a uma haste de vidro, facilitando a introdução e retirada do interior do tubo de vidro. O sistema proposto possibilitou uma drástica redução no tempo de preparo de amostra e melhor eficiência de decomposição (menor teor de carbono residual) em comparação com os procedimentos convencionais. O sistema "quase fechado" associado a baixas temperaturas atingidas evitou perdas de elementos por volatilidade, além de apresentar uma ótima homogeneidade de aquecimento entre os microfrascos. A exatidão da metodologia foi verificada através de ensaios de recuperação da análise de um material de referência certificado (IAEA-086) e da análise de amostra com adição e recuperação dos analitos apresentando recuperações de 90 a 103%.
Título en inglés
Use of microwaved digestion microwaves focused as an alternative to the preparation of samples
Palabras clave en inglés
Absorption (Chemical analysis)
Atomic absorption
Elementary hair analysis
Experimental sampling (Chemical analysis)
FAAS
Focused microwaves
Sample preparation
Resumen en inglés
In this work the use of polypropylene vials adapted at focused m1crowaves, as alternative method for sample preparation is proposed. The sample pre-treatment in digestion vials include some desirable characteristics like increase of analytical frequency, low sample mass and low reagents consumption. To check the efficiency of the digestion system the development of a methodology for copper, iron, manganese, selenium and zinc determination using graphite furnace or flame atomic absorption spectrometry was performed. The selected elements are essential for human individual, nutritional indicators and required for enzymatic working. The digestion system is constituted of a focused microwave oven, a glass tube with 30 cm length and 4 cm width, where are setting four or five polypropylene vials with capacity for 4.0 mL and 2.0 mL, respectively, through a Teflon® support assisted by glass haste. The proposed system allowed a drastic reduction of sample preparation time and improved the decomposition efficiency (lower carbon residual content) comparing with conventional methods. The "almost closed" system associated with the low temperature avoids elements losses and improve heating homogeneity among the vials. The accuracy of the methodology was ascertained through good recoveries for a certificate reference material (IAEA-086) analysis and good recovery of spiked sample analysis, presenting recovery 90 to 103%.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2018-02-15
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.