• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Thèse de Doctorat
DOI
https://doi.org/10.11606/T.46.2007.tde-14082007-111340
Document
Auteur
Nom complet
Denise Lowinsohn
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2007
Directeur
Jury
Bertotti, Mauro (Président)
Fatibello Filho, Orlando
Gutz, Ivano Gebhardt Rolf
Richter, Eduardo Mathias
Serrano, Silvia Helena Pires
Titre en portugais
Desenvolvimento de um sensor para análise de lactato em amostras alimentares e biológicas
Mots-clés en portugais
Biossensor
Enzima
Fia
Lactato
Lactato oxidase
Resumé en portugais
Neste trabalho são apresentados resultados relacionados a estudos sobre o comportamento eletroquímico do lactato e do peróxido de hidrogênio em diversos eletrodos em meio de diferentes pHs utilizando voltametria cíclica. Também foi investigado o comportamento eletroquímico do peróxido de hidrogênio em eletrodos modificados com filmes de hexacianoferratos utilizando eletrodos de platina e carbono vítreo. A vantagem do uso do CTAB na modificação da superfície de carbono vítreo com Azul da Prússia foi confirmada no que se refere à melhora da sensibilidade e da estabilidade das medidas. Numa etapa posterior desenvolveu-se um biossensor para a determinação de lactato pelo monitoramento de peróxido de hidrogênio produzido na reação catalisada de lactato com oxigênio na presença da enzima lactato oxidase. Nessa etapa, o trabalho consistiu em imobilizar a enzima lactato oxidase na superfície do eletrodo, previamente, modificado com Azul da Prússia, com o auxílio de Nafion®. Após a construção do biossensor e a otimização das condições de análise (pH, quantidade de enzima, volume da amostra e vazão) para obtenção de maior sinal analítico no desenvolvimento do método para a determinação de lactato por análise em fluxo, averiguou-se a repetibilidade das medidas (Clactato = 0,28 mmol L-1) obtendo-se um desvio padrão de 2,2% para 18 repetições. A freqüência analítica foi estimada em 160 injeções por hora com limite de detecção de 0,84 µmol L-1 e linearidade até 0,28 mmol L-1 de lactato. O biossensor foi aplicado na quantificação de lactato em amostras alimentares (cervejas alcoólicas e não alcoólicas) e biológicas (sangue liofilizado e recém coletado). Por fim, realizaram-se estudos envolvendo a variação da concentração de lactato sanguíneo em função da intensidade de atividade esportiva. Os resultados obtidos pelo método proposto foram comparados com aqueles oriundos do uso de método de referência.
Titre en anglais
Fabrication of a biosensor for determination of lactate in food and blood samples
Mots-clés en anglais
Biosensor
Enzyme
Fia
Lactate
Lactate oxidase
Resumé en anglais
Results on the investigation of the electrochemical behavior of lactate and hydrogen peroxide at various electrodic surfaces at different pHs using cyclic voltammetry are presented. Experiments were also carried out with platinum and glassy carbon electrodes modified with hexacyanoferrate films. The advantage of using CTAB in the electrodeposition step of Prussian Blue films onto glassy carbon surfaces was confirmed taking into account both the stability and sensitivity of measurements. The immobilization of lactate oxidase onto glassy carbon electrodes modified with a Prussian Blue layer using Nafion® was performed to fabricate a biosensor for lactate. The biosensor was used in the development of a FIA amperometric method for the determination of lactate. Under optimal operating conditions (pH = 6.9, E = -0.1 V), the linear response of the method was extended up to 0.28 mmol L-1 lactate with a limit of detection of 0.84 µmol L-1. The repeatability of the method for injections of a 0.28 mmol L-1 lactate solution was 2.2 % (n = 18). The analytical frequency was calculated as 160 injections h-1. The usefulness of the method was demonstrated by determining lactate in beer (alcoholic and nonalcoholic beers) and blood samples (lyophilized and freshly collected). Finally, the influence of physical exercise on the blood lactate level was studied. Results obtained by using the proposed amperometric detector compared well with the reference method.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
LDENISETESE.pdf (1.22 Mbytes)
Date de Publication
2007-09-12
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.