Master's Dissertation
DOI
https://doi.org/10.11606/D.46.2004.tde-14062007-160003
Document
Author
Full name
Thiago Regis Longo Cesar da Paixão
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2004
Supervisor
Committee
Bertotti, Mauro (President)
Agostinho, Silvia Maria Leite
Fatibello Filho, Orlando
Title in Portuguese
Utilização de eletrodos de Cu e Au em eletroanalítica: detecção amperométrica de etanol em ar exalado e outras aplicações
Keywords in Portuguese
Ácido ascórbico
Amperometria
Ar exalado
Dipirona
Eletrodo de cobre
Eletrodo de ouro
Etanol
Glicose
Sistema gerador-coletor em fluxo
Titulação em camada delgada
Abstract in Portuguese
A potencialidade do eletrodo de cobre em meio alcalino foi demonstrada para o determinação de etanol a +0,6 V vs Ag/AgCl. A participação de espécies solúveis de Cu(III) no processo eletrocatalítico envolvendo a oxidação do etanol foi demonstrada por experimentos utilizando eletrodo disco-anel. A influência do potencial de pré-tratamento no sinal anódico foi investigada e correlacionada com a morfologia dos filmes formados na superfície do eletrodo por EDS (Energy Dispersive X-Ray Spectroscopy), indicando que as espécies de Cu(III) são originadas a partir da oxidação da camada de CuO. As medidas de etanol foram realizadas por amperometria em 0,6 V (vs Ag/AgCl). A repetibilidade das medidas utilizando padrão aquoso de etanol 0,05 % (v/v) foi de 3 % (v/v) e os limites de detecção e quantificação foram de 0,005 % (v/v) e 0,01 % (v/v), respectivamente. Nas condições experimentais otimizadas, o sensor amperométrico foi utilizado para o monitoramento da concentração de etanol no ar exalado (BrAC), que foi convenientemente coletado em um balão de borracha (V = 3 L) e introduzido em uma solução de NaOH 1 mol L-1 (V = 10 mL). O sensor apresentou uma faixa linear para concentrações de etanol em ar exalado na faixa de 0,26 – 130 mg L-1, operando de acordo com os parâmetros analíticos especificados na Legislação Brasileira para a quantificação de etanol no ar exalado em condutores de veículos automotores. A constante de eliminação de etanol do corpo humano também foi investigada e os resultados concordaram com os valores da literatura. Empregando-se eletrodos de Cu e Au foram também desenvolvidas outras metodologias para a quantificação de dipirona, glicose e ácido ascórbico e sistemas em fluxo. Estudos sobre o desenvolvimento e propriedades de um sistema gerador-coletor foram realizados e o dispositivo foi utilizado em titulações de substâncias redutoras com iodo gerado eletroquimicamente.
Title in English
Utilization of gold and copper electrodes in electroanalysis: amperometric detection of ethanol in breath and other applications
Keywords in English
Ascorbic acid
Breath alcohol
Copper electrode
Diffusion layer titration
Dypirone
Electrochemical cell
Ethanol
Glucode
Gold electrode
Thin-layered dual-band
Abstract in English
A copper disc working electrode in alkaline solutions was demonstrated to act as a suitable amperometric sensor for ethanol determination at +0.6 V vs Ag/AgCl. The participation of free-soluble Cu(III) species in the electrocatalytic process involving the anodic oxidation of ethanol has been demonstrated by rotating ring-disc electrode voltammetry. The influence of the pretreatment potential on the anodic signal was investigated and a correlation with the morphology of the electrode surface characterized by Energy Dispersive X-Ray Spectroscopy (EDS) indicated that the Cu(III) species is originated from the oxidation of a CuO layer. Ethanol measurements were performed in the amperometric mode at 0.6 V (vs Ag/AgCl). The repeatability of the measurements for a 0.05 % aqueous ethanol solution was estimated as 3 %, and the detection and quantification limits were determined as 0.005 % and 0.01 %, respectively. At the optimum experimental conditions, the amperometric sensor was used to monitor the concentration of ethanol in breath (BrAC), which was conveniently collected in a rubber air balloon (volume = 3 L) and introduced in a 1 mol L-1 NaOH working solution (volume = 10 mL). The sensor can measure a person's breath ethanol over the concentration range 0.26 - 130 mg L-1 by operating it according to an established protocol, of which the analytical parameters are specified by the Brazilian Legislation for BrAC measurements in drivers. The rate of ethanol degradation in the body was followed, and the results agree with predictions in the literature. Methodologies for the determination of dipyrone, glucose and ascorbic acid were also developed by using Cu and Au electrodes. Features of a dual-band electrochemical cell were investigated towards the development of a generator-collector system, which was employed in titrations with electrogenerated iodine.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
dissertacao_final.pdf (9.87 Mbytes)
Publishing Date
2007-06-21
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.