• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.46.2000.tde-12112007-145103
Document
Author
Full name
Carlos Antonio Neves
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2000
Supervisor
Committee
Lago, Claudimir Lúcio do (President)
Petri, Denise Freitas Siqueira
Rohwedder, Jarbas José Rodrigues
Title in Portuguese
Dispositivos para cristais piezelétricos de quartzo com eletrodos separados para estudos de processos físicos e químicos de superfícies e filmes depositados
Keywords in Portuguese
Análise de impedância
Cristal pizelétrico de quartzo de eletrodos separados
ESPC
PQC
Química analítica
Silanização
Abstract in Portuguese
Este trabalho descreve o desenvolvimento de dispositivos usando cristais piezelétricos de quartzo com eletrodos separados (ESPC) que, através do monitoramento da freqüência de oscilação e do espectro de impedância, permitem estudar modificações superficiais do cristal. Para o monitoramento de freqüência de oscilação, usou-se um circuito oscilador TTL seguido por um freqüencímetro e por uma interface conectada a um microcomputador. Para o controle desta interface, foi desenvolvida uma biblioteca de ligação dinâmica e um programa em HP-VEE 4.0. Os espectros de impedância foram obtidos via programas que controlam um analisador de impedâncias via protocolo GPIB. O primeiro dispositivo presta-se a estudos de filmes depositados (DFD) e é feito em acrílico com eletrodos em latão posicionados a décimos de milímetros do cristal. Sua parte superior possui uma camisa de água para a termostatização. O segundo, semelhante ao primeiro, permite a modificação de superfície (DMS) de ESPC através da introdução de reagentes na fase gasosa. Os dois dispositivos foram caracterizados e o primeiro mostrou boa linearidade entre as massas depositadas e aquelas estimadas pela equação de Sauerbrey. O DFD foi utilizado para monitoramento em tempo não real da modificação superficial do cristal por N-[3-(trimetoxisilil)propil]-1,2-etanodiamina seguida por reação com ácido iodoacético. Os resultados mostraram evidências de aumento de massa e mudança nas propriedades viscoelásticas do filme. O DMS foi utilizado para monitoramento em tempo real da modificação superficial com trimetilclorosilano (TMCS) e dimetildiclorosilano (DMDCS). Com o TMCS, devido à formação de uma monocamada, não foi possível monitorar variações significativas de freqüência de oscilação. Com o DMDCS foi possível verificar a formação de poli(dimetilsiloxano).
Title in English
Separated electrodes piezelectric quartz crystal devices for studies ogf physical and chemical process and film coated
Keywords in English
Analytical chemistry
Electrodes separated piezelectric quartz crystal
ESPC
Impedance analysis
PQC
Sinalization
Abstract in English
This dissertation describes the development of devices based on separated-electrode piezoelectric quartz crystals (ESPC) to study surface modifications. This is accomplished by monitoring the oscillation frequency and impedance spectrum of the crystal in the cell. A TTL oscillator coupled to a frequency counter and a microcomputer interface is used for monitoring the oscillation frequency. A dynamic link library and HP-VEE 4.0 programs were developed to control the interface. Other programs were also developed to acquire the impedance spectra from a spectrum analyzer by using the GPIB protocol. The first device (DFD) is intended to study deposited films. It is made in Plexiglas, with brass electrodes positioned at a few tenths of millimeters from the crystal surface, and a thermostatic water jacket. The second device (DMS) is similar to the first one, but allows the use of corrosive reagents in the gas phase for surface modification. The performance of both devices was evaluated and the results showed good agreement between the deposited mass and the one predicted by Sauerbrey equation. The DFD was used for offline monitoring of the crystal surface modification by N-[3-(triethoxysilyl)propyl]-1,2-ethanediamine followed by iodoacetic acid. The results show evidences of mass and viscoelastic variations of the film. The DMS was used for on-line monitoring during surface modification with trimethylchlorosilane (TMCS) and dimethyldichlorosilane (DMDCS). Due to the monolayer formed by TMCS, no significant frequency variation could be observed. On the other hand, the polymerization of DMDCS could be monitored.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2007-11-14
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.