Disertación de Maestría
DOI
https://doi.org/10.11606/D.46.2006.tde-12082007-200126
Documento
Autor
Nombre completo
Daniela de Santi Scatamachia
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2006
Director
Tribunal
Oliveira, Pedro Vitoriano de (Presidente)
Correia, Paulo Rogério Miranda
Nóbrega, Joaquim de Araújo
Título en portugués
Explorando a espectrometria de absorção atômica com atomização eletrotérmica e amostragem direta em superfície metálica para a determinação de bário
Palabras clave en portugués
Absorção atômica
Amostragem direta
Bário
Superfície metálica
Resumen en portugués
A eficiência de atomização do bário, em superfície grafítica, é fortemente afetada pela formação de espécies refratárias, como carbetos e óxidos. Várias tentativas vêm sendo propostas no sentido de melhorar o limite de detecção do bário em espectrometria de absorção atômica com forno de grafite. Nesse sentido, o presente trabalho teve como objetivo estudar a viabilidade de se utilizar uma plataforma de tungstênio adaptada ao tubo de grafite do espectrômetro de absorção atômica, visando melhorar a eficiência de atomização do bário bem como a sua determinação em petróleo, óleos lubrificantes, água do mar e água mineral. O sistema proposto constituiu-se de uma plataforma de tungstênio com superfície modificada eletroliticamente com ródio, adaptada a um tubo de grafite com parede interna modificada com irídio. A mistura de 10% (v/v-1) H2 + 90% (v/v-1) Ar como gás de purga aumentou a eficiência de atomização, o tempo de vida do tubo de grafite e da plataforma. O uso de 10 µg de (NH4)2HPO4 como modificador químico foi indispensável para a determinação de bário em água mineral e de mar. O limite de detecção foi de 3,5+/-0,3 µg L-1 e a massa característica de 2,1 pg. Com a plataforma de tungstênio modificada com ródio foi possível gerar um sinal transiente de absorbância com temperatura de atomização de 2400 oC, com tempo de residência de, aproximadamente, 0,5 s, contra uma temperatura de atomização de 2600 oC para o forno de grafite, com tempo de residência de 15 s. A vida útil da plataforma de tungstênio, modificada com ródio, e do tubo de grafite foram, respectivamente, 200 e 750 ciclos de aquecimento.
Título en inglés
Feasibility to use metalic platform to the graphite tube of the electrothermal atomic absorption spectrometry for barium determination
Palabras clave en inglés
Atomic absorption
Barium
Metlic surface
Tungsten
Resumen en inglés
The atomization efficiency of barium in graphite furnace is strongly affected by the refractory species formation, such as, carbides and oxides. Several attempts have been done to overcome these drawbacks and to improve the sensitivity of barium in electrothermal atomic absorption spectrometry. Thus the aim of the present work was to propose a tungsten platform inserted into the graphite tube of the atomic absorption spectrometer for the determination of barium in petrol, lubrificating oil, drinking water and seawater. The proposed system consisted of a tungsten platform electrolitically modified with rhodium and a graphite tube with the internal wall modified with iridium. The mixture of 10 % (v/v-1) H2 + 90% (v/v-1) Ar was used as purge gas, increasing the atomization efficiency, the graphite tube and the tungsten platform lifetime. The use of 10 µg de (NH4)2HPO4 as chemical modifier was imperative for the determination of barium in drinking water and seawater. After the optimization, the detection limit was 3.5+/-0.3 µg L-1 and the characteristic mass was 2.1 pg. By using the tungsten platform modified with rhodium it was possible to obtain a transient absorbance signal at 2400 oC atomization temperature, with residence time of 0.5 s, against 2600 oC atomization temperature in graphite tube platform, with residence time of 15 s. The lifetimes of the tungsten platform modified with rhodium and the graphite tube were 200 and 750 heating cycles, respectively.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
FOLHAS.pdf (11.03 Kbytes)
Fecha de Publicación
2008-01-31
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.