Thèse de Doctorat
DOI
https://doi.org/10.11606/T.46.2006.tde-11042007-095255
Document
Auteur
Nom complet
Cassiana Seimi Nomura
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2006
Directeur
Jury
Oliveira, Pedro Vitoriano de (Président)
Flores, Érico Marlon de Moraes
Lago, Claudimir Lucio do
Nogueira, Ana Rita de Araújo
Rocha, Fábio Rodrigo Piovezani
Titre en portugais
Estudo de parâmetros associado à análise direta de sólidos por espectrometria de absorção atômica com atomização eletrotérmica
Mots-clés en portugais
Cabelo
Espectrometria
ETAAS
Fígado
Músculo bovino
Resumé en portugais
Neste trabalho foi feito um estudo sistemático para avaliar a influência dos principais parâmetros associados à análise direta de sólidos por espectrometria de absorção atômica com atomização eletrotérmica. Os parâmetros avaliados foram secagem, moagem, tamanho de partículas, massa de amostra e homogeneidade na determinação de Al, As, Cd, Cr, Cu, Pb, Ni e Zn em fígado e músculo bovino. Além desses estudos foram desenvolvidos métodos para a determinação de As, Cd, Cr e Pb em cabelo e de As, Cd, Cu, Cr, Ni, Pb e Zn em material particulado urbano. A adequada otimização dos programas de aquecimento e o uso de modificadores químicos permitiram que, na maioria dos casos, a calibração do espectrômetro fosse feita com soluções de referência. O fígado e o músculo bovino foram preparados seguindo diferentes procedimentos de secagem: (1) liofilização e (2) secagem em forno de microondas doméstico seguida pela estufa a 60 oC até atingir massa constante. O moinho de bolas e o moinho criogênico foram utilizados para a moagem. Todos os materiais apresentaram homogeneidade adequada para serem aplicados em análises de massas inferiores a 100 µg, exceto o Pb, cuja massa mínima foi de 600 µg. O fígado seco em forno de microondas seguida pela estufa e moído em moinho criogênico foi o que apresentou a melhor homogeneidade, podendo ser aplicado para análise de massas em torno de 30 µg, no caso da determinação de Cu. Devido à capacidade da SS-ETAAS analisar diminutas massas de amostras, foi possível avaliar a distribuição de Cd e Pb ao longo do fio de cabelo. Esse estudo mostrou que, por meio desse tipo de análise, é possível obter informações a respeito dos episódios do passado relevantes à saúde, mesmo que a ação já tenha cessado, podendo ser utilizado em investigações forenses. O trabalho envolvendo a análise de material particulado urbano faz parte do processo de certificação de um novo material de referência certificado para microanálise (SRM 1648a), em processo de produção no National Institute of Standard and Technology (NIST). Resultados da avaliação de homogeneidade indicaram que massas de amostra inferiores a 50 µg podem ser utilizadas.
Titre en anglais
Study of parameters associated to solid sampling electrothermal atomic absorption spectrometry
Mots-clés en anglais
Bovine muscle
ETAAS
Hair
Liver
Spectroscopy
Resumé en anglais
In this work, a systematic study to evaluate the influence of the main parameters associated to solid sampling electrothermal atomic absorption spectrometry was done. The parameters evaluated were the sample drying and grinding, the particle size, the sample size and the homogeneity and their influence on Al, As, Cd, Cr, Cu, Pb, Ni and Zn determinations in bovine liver and muscle. Beyond these studies, methods for As, Cd, Cr and Pb determinations in hair and As, Cd, Cu, Cr, Ni, Pb and Zn determinations in urban particle matter were developed. The heating program optimization and the adoption of some strategies such as the use of chemical modifier allowed, in the most of cases, analyzing solid samples against aqueous calibration. Bovine liver and muscle were prepared following different drying procedures: (1) freeze-drying process and (2) drying in a domestic microwave oven followed by drying in a stove at 60oC until constant mass. Ball and cryogenic mills were used to grind the samples. All prepared materials presented good homogeneity to be applied in analysis of sample mass size lower than 100 µg, except to Pb. In this case, the minimal sample mass size was 600 µg. Bovine liver dried in a microwave oven followed by drying in a stove and ground in a cryogenic mill presented the best homogeneity. For Cu determination, 30 µg of this material could be used. Due to the capacity of SS-ETAAS in analyzing very low sample mass size, it was possible to evaluate the Cd and Pb distribution through the extent of the hair. This study showed that it is possible to retrieve information about past health issues, even if its cause has ceased. In this way, it can be applied in a forensic science. The urban particle matter analysis is related to certification process of the new certified reference material for microanalysis (SRM 1648a) in production process at National Institute of Standard and Technology (NIST). Results of homogeneity evaluation showed sample mass size lower than 50 µg can be used without affecting the precision and accuracy of the results.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
TESE.pdf (918.14 Kbytes)
Date de Publication
2007-04-13
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.