• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.46.2018.tde-10092018-153423
Document
Author
Full name
Maura Vincenza Rossi
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 1986
Supervisor
Committee
Neves, Eduardo Fausto de Almeida (President)
Massaro, Sergio
Santoro, Maria Ines Rocha Miritello
Title in Portuguese
Método alternativo para a determinação complexométrica de magnésio. Influência do volume nas titulações potenciométricas
Keywords in Portuguese
EDTA
Magnésio
Potenciometria
Abstract in Portuguese
No presente trabalho comprova-se o efeito prejudicial do oxalato, utilizado para a separação prévia de cálcio e magnésio, na determinação complexométrica deste último com EDTA em águas, usando-se em titulação visual o indicador Negro de Eriocromo T e, em titulação potenciométrica, o sistema indicador Hg/Hg-EDTA. Comprovou-se, também, a viabilidade de se usar como titulante uma solução de EDTA "tetraneutralizado", em titulações potenciométricas com medidas de pH através de eletrodo de vidro combinado. Neste caso o ponto final é obtido através da hidrólise da espécie Y4-, após o ponto de equivalência. Assim evidenciou-se a viabilidade de um novo método para a determinação da mistura de cálcio e magnésio, pelo uso EDTA "tetraneutralizado" e separação prévia dos dois cátions através da adição de oxalato. A detecção do ponto final nestas titulações com EDTA "tetraneutralizado" pode também ser feita visualmente com fenolftaleína. O efeito de volume em titulações potenciométricas em geral, num certo nível de concentração, foi objeto de análises diversas inclusive por cálculo computacional de curvas derivativas. Comprovou-se que quanto menor o volume do titulado maior é o salto potenciométrico obtido, caracterizando-se o que se denominou de "paradoxo potenciométrico", pois uma menor massa de substância pode ser titulada com, teoricamente, o mesmo erro relativo que para uma massa maior de substância.
Title in English
Alternative method for the complexometric determination of magnesium. Influence of volume on potentiometric titrations
Keywords in English
EDTA
Magnesium
Potentiometry
Abstract in English
Alternative method for the complexometric determination of magnesium. Influence of volume on potentiometric titrations. Keywords: Potentiometry, Magnesium, EDTA. Present paper has been found the negative effect of oxalate, used to the previous separation of calcium and magnesium in a complexometric determination of this last with EDTA in waters, using at visual titration Eriochrome black T as indicator and at potentiometric titration the indicator system Hg/Hg-EDTA. It has been found, also, the viability in the use as titrant a "tetraneutralized" EDTA solution, in potentiometric titration with measurements of pH with the glass electrode. In this case the end point is obtained on basis of hydrolysis of Y4- species, after the equivalent point. So it has been displayed the viability of a new method to the determination of the mixture calcium and magnesium by the use of "tetraneutralized" EDTA and previous separation of both cations by addition of oxalate. The end point detection can be visually found, in these titrations with "tetraneutralized" EDTA, by using of phenolphthalein. The effect of volume in potentiometric titration in general, at a defined concentration level, was subject of several analysis incluse using the compute calculation of derivative curves. It has been found that as smaller volume of titrated performes a higher potentiometric jump, this effect was called for us "potentiometric paradox", since an smaller weight of substance can be titrated, with theoretically, the same relative error that to a greater weight of substance.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2018-09-10
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.