• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.46.2009.tde-05102009-100831
Documento
Autor
Nombre completo
Ivan Alexandre Petroni
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2009
Director
Tribunal
Masini, Jorge Cesar (Presidente)
Assunção, João Vicente de
Freire, Renato Sanches
Título en portugués
Poluição do ar por compostos orgânicos voláteis (COV) em ambiente interno hospitalar
Palabras clave en portugués
Ambientes internos
Ar
Compostos carbonílicos
Compostos orgânicos voláteis (COV)
Fontes de emissão
Hospitais
Química Analítica
Resumen en portugués
A quantificação de 11 compostos carbonílicos (formaldeído, acetaldeído, acetona, acroleína, propionaldeído, crotonaldeído, butiraldeído, benzaldeído, isovaleraldeído, valeraldeído e 2,5-dimetilbenzaldeído) e a identificação de outros 43 compostos orgânicos voláteis (alcanos, alcenos, aromáticos, halogenados e nitrogenados) foram feitas em 9 ambientes diferentes de trabalho localizados em áreas internas do Hospital Universitário, USP, São Paulo. Dentre os compostos carbonílicos, os mais abundantes em ordem decrescente foram formaldeído, acetona, acetaldeído e acroleína. As maiores razões de mistura de formaldeído foram observadas nas salas de Macroscopia (169,9 e 90,2 ppbv) e Técnicas Histológicas (11,7 e 58,7 ppbv), em decorrência da atividade desenvolvida nos locais. Na sala de Macroscopia, os níveis de formaldeído encontrados foram acima do limite (100 ppbv) estabelecido por órgãos internacionais que controlam a qualidade do ar em ambientes internos não industriais. As razões de mistura entre o ambiente interno e o ambiente externo, razões I/E, permitiram indicar a predominância dos compostos carbonílicos nos ambientes internos. A acroleína foi encontrada na faixa de 6,4 a 9,3 ppbv nos ambientes internos estudados. Na área externa, entretanto, foram encontrados valores similares (6,4 e 6,8 ppbv) aos dos ambientes internos obtendo razões I/E próximas de 1. Os compostos podem ter sido emitidos por materiais de construção e acabamento, fumaça do tabaco, adesivos, via metabolismo microbiano e bacteriano ou podem ter sido transportados por correntes de ar do ambiente externo para o ambiente interno
Título en inglés
Air pollution by volatile organic compounds (VOCs) inside hospital
Palabras clave en inglés
Air
Analytical chemistry
Carbonyl compounds
hospital
indoor
Missions sources
volatile organic compound (VOCs)
Resumen en inglés
The quantification of 11 carbonyl compounds (formaldehyde, acetaldehyde, acrolein, acetone, propionaldehyde, crotonaldehyde, butiraldehyde, benzaldehyde, isovaleraldehyde, valeraldehyde and 2,5-dimethylbenzaldehyde) and the identification of another 43 volatile organic compounds (alkanes, alkenes, aromatic, halogenated and nitrogenated compounds) have been done with samples of 9 different indoor places inside the University Hospital at USP in São Paulo. Among the carbonyl compounds, there where found higher quantities of formaldehyde, acetone, acetaldehyde and acrolein in this order. The highest ratios of formaldehyde mixture have been observed at the Macroscopic room (169.88 and 90.2 ppbv) and Histological Techniques (11.7 and 58.7 ppbv), due to the routine activities of these places. At the Macroscopy room, the level of formaldehyde identified (100 ppbv) was above the international limits established to non-industrial internal places. The ratios of the mixture of indoor and outdoor places, I/O, indicate the biggest presence of carbonyl compounds in internal places. Acrolein has been identified (6.4 to 9.3 ppbv) at indoor places. At the external area, there where found similar values (6,4 to 6,8 ppbv), and the ratio I/O obtained is near to 1. The origin of these compounds is possibly construction materials, smoke of cigarettes, adhesives, metabolism of microorganisms or they may have come from the outdoor to the indoor
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
ErrataIvanAPetroni.pdf (21.21 Kbytes)
Fecha de Publicación
2009-12-08
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.