• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tesis Doctoral
DOI
https://doi.org/10.11606/T.46.2010.tde-10112010-113020
Documento
Autor
Nombre completo
Mariana Pereira Massafera
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2010
Director
Tribunal
Torresi, Susana Ines Cordoba de (Presidente)
Bertotti, Mauro
Crespilho, Frank Nelson
Kubota, Lauro Tatsuo
Sumodjo, Paulo Teng An
Título en portugués
Desenvolvimento de novas plataformas poliméricas para detecção eletroquímica de amônia e uréia
Palabras clave en portugués
Amônia
Nanoestruturas
Poli(pirrol)
Sensores
Urease
Uréia
Resumen en portugués
Este trabalho apresenta o desenvolvimento de (bio)sensores baseados em plataformas poliméricas convencionais e nanoestruturadas. Os sensores estudados contém poli(pirrol) como transdutor eletroquímico, responsável pela oxidação de amônia a 0,35 V. Como a enzima urease hidrolisa cataliticamente uréia a amônia, após a imobilização da enzima sobre o poli(pirrol), obtém-se um biossensor para detecção indireta de uréia, via amônia. A detecção de amônia pelo poli(pirrol) foi otimizada em termos da densidade de carga de poli(pirrol) presente no sensor, e do potencial de trabalho. Então verificou-se a ação do polímero poli(5-amino-1-naftol) na redução do sinal dos interferentes ácidos úrico e ascórbico. Após a otimização do sensor-base, estudou-se a influência do tipo de imobilização da urease ao substrato polimérico na sensibilidade e estabilidade do biossensor de uréia. Concluiu-se que a pouca quantidade de enzima imobilizada através das metodologias estudadas era o fator limitante da sensibilidade de detecção, e então implementou-se a nanoestruturação do poli(pirrol), para aumentar a área superficial disponível para a imobilização da urease. Preparou-se filmes de poli(pirrol) nanoestruturado (macroporoso e nanofios), e a compreensão dos fenômenos observados só foi possível ao aliar características geométricas e propriedades físico-químicas intrínsecas de sistemas nanoestruturados.
Título en inglés
Development of new polymeric platforms for ammonia and urea electrochemical detection
Palabras clave en inglés
Ammonia
Nanostructures
Poly(pyrrole)
Sensors
Urea
Urease
Resumen en inglés
This work presents the development of (bio)sensors based on conventional and nanostructured polymeric platforms. The analyzed sensors contain poly(pyrrole) as electrochemical transducer, responsible for ammonia oxidation at 0.35 V. As the enzyme urease catalytically hydrolyses urea to ammonia, after enzyme immobilization onto poly(pyrrole), a biosensor for urea indirect detection, via ammonia, is obtained. Ammonia sensing by poly(pyrrole) was optimized in terms of both charge density of poly(pyrrole) present in the sensor and working potential. In sequence, poly(5-amino-1-naphtol) role as interferents (uric and ascorbic acids) signal blocker was verified. After optimization of the base-sensor, the influence of urease immobilization method on both detection sensitivity and biosensor durability was investigated. It was found that the small amount of enzyme immobilized using the compared methods limited detection sensitivities, and then nanostructuration of poly(pyrrole) was implemented, in order to increase the surface area available for urease immobilization. Nanostructured poly(pyrrole) films (macroporous and nanowires) were prepared, and the fully understanding of the observed phenomena was only possible combining geometric characteristics and physical-chemical properties related to nanostructured systems.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2011-01-20
 
ADVERTENCIA: El material descrito abajo se refiere a los trabajos derivados de esta tesis o disertación. El contenido de estos documentos es responsabilidad del autor de la tesis o disertación.
  • GONçALES, Vinicius R., et al. Nanostructured thin films obtained by electrodeposition over a colloidal crystal template : applications in electrochemical devices [doi:10.1590/S0103-50532009000400010]. Journal of the Brazilian Chemical Society [online], 2009, vol. 20, n. 4, p. 663-673.
  • MASSAFERA, Mariana P., and CóRDOBA DE TORRESI, Susana I.. Evaluating the performance of polypyrrole nanowires on the electrochemical sensing of ammonia in solution [doi:10.1016/j.jelechem.2012.01.004]. Journal of Electroanalytical Chemistry [online], 2012, vol. 669, p. 90-94.
  • MASSAFERA, Mariana P., and DE TORRESI, Susana I. Córdoba. Urea Amperometric Biosensors Based on Nanostructured Polypyrrole [doi:10.1002/elan.201100239]. Electroanalysis [online], 2011, vol. 23, n. 11, p. 2534-2540.
  • MASSAFERA, Mariana P., and TORRESI, Susana I. Córdoba de. Urea amperometric biosensors based on a multifunctional bipolymeric layer : Comparing enzyme immobilization methods [doi:10.1016/j.snb.2009.02.013]. Sensors and Actuators B: Chemical [online], 2009, vol. 137, n. 2, p. 476-482.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.