• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.46.2010.tde-12042011-135130
Document
Author
Full name
Rodrigo Matias Trolise
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2010
Supervisor
Committee
Baptista, Mauricio da Silva (President)
Carmona-Ribeiro, Ana Maria
Oliveira Junior, Osvaldo Novais de
Title in Portuguese
Desenvolvimento de metodologia para funcionalizar superfícies de ouro com biomoléculas. Construção de biosensor para detecção de citocromo c.
Keywords in Portuguese
Biosensores
Citocromo c
Fosfolipídeos
Limite de detecção
Quitosana
Ressonância de plasmons de superfície
Abstract in Portuguese
Neste trabalho estão apresentadas novas estratégias para funcionalizar superfícies de ouro baseadas na sustentação de bicamadas lipídicas em superfícies de sensores de imagem por Ressonância de Plasmons de Superfície (SPRi) e a construção de um biosensor para detecção de citocromo c. SPRi é uma técnica ótica de gravimetria em tempo real. Por meio de medidas de variações de índice de refração (n) próximas a uma interface, a adsorção e desorção de moléculas podem ser mensuradas. Inicialmente testamos várias estratégias para encontrar um suporte adequado que se ligasse na superfície de ouro e que oferecesse sustentação e estabilidade para a bicamada de fosfolipídeo biotinilado. Estudos de FT-IR e MEV mostraram que a quitosana facilita a formação de uma bicamada íntegra de fosfolipídeos, de tal modo, que a mesma alcança valores de espessura próximos àqueles previstos, ~ 34,5 Å. Além disso, mostramos que esse sistema apresenta vantagens perante outros modelos, tais como, (poli-lisina/fosfolipídeos) e (tiol hidrofóbico/fosfolipídeo). Utilizando-se o complexo químico biotina/estreptoavidina conseguimos imobilizar o anticorpo anti cit c na bicamada, mantendo-o afastado da superfície de ouro. A construção do biosensor foi acompanhada com experimentos de SPRi. O limite de detecção de citocromo c atingido foi de 10-11mol/L. Um sensor construído somente com BSA e anticorpo anti cit c apresentou sensibilidade semelhante. Esta sensibilidade é em torno de três ordens de grandeza superior aos experimentos de imunoblotting usualmente utilizados para detecção de cit c. A principal limitação deste biosensor, tal como de outros imunoensaios, está intimamente ligada às vantagens e desvantagens dos anticorpos como ferramentas analíticas.
Title in English
Development of methodology to functionalize gold surfaces with biomolecules. Construction of biosensor for detection of cytochrome c
Keywords in English
Biosensors
Chitosan
Cytochrome c
Limit of detection
Phospholipids
Surface plasmon resonance
Abstract in English
In this work we developed new strategies to functionalize gold surfaces based on the support of lipid bilayers on the surfaces of surface plasmon resonance imaging sensors (SPRi) and the construction of a biosensor for detection of cytochrome c. SPRi is an optical gravimetric real time technique. Through measurements of changes in refractive index (n) in close proximity to an interface, the adsorption and desorption of molecules can be measured. Initially we tested several strategies for finding a suitable medium that would adsorb on the gold surface and also support and stabilize a biotinylated phospholipid bilayer. Studies of FT-IR and SEM showed that chitosan induces the formation of an intact phospholipid bilayer, so that it reaches thickness values close to those expected, ~ 34.5 Å. Furthermore, we showed that this system has advantages in relation to other models, such as (poli-lisine/phospholipids) and (thiol hydrophobic / phospholipid). Using the chemical complex biotin/streptavidin anti cyt c antibody could be immobilized in the bilayer, keeping it away from the gold surface. The construction of the biosensor was accompanied with SPRi experiments. The limit of detection of cytochrome c was achieved from 10-11mol / L. A sensor built only with BSA and anti cyt c showed similar sensitivity. This sensitivity is about three orders of magnitude higher than the immunoblotting experiments commonly used for detection of cyt c. The main limitation of this biosensor, like in other immunoassays, is linked to the advantages and disadvantages of antibodies as analytical tools.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2011-06-13
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.