• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.45.2017.tde-17052017-161610
Document
Author
Full name
Rafael Reggiani Manzo
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2017
Supervisor
Committee
Jackowski, Marcel Parolin (President)
Finger, Marcelo
Sato, João Ricardo
Title in Portuguese
Um método de tractografia global usando imagens de ressonância magnética ponderadas por difusão
Keywords in Portuguese
Imagens de ressonância magnética ponderadas por difusão
Simulação de partículas
Tractografia
Abstract in Portuguese
As imagens de ressonância magnética ponderadas por difusão retratam a difusividade de moléculas de água presentes em tecidos biológicos. Em estruturas biológicas altamente organizadas e compactas como fibras nervosas e musculares, a difusividade é maior na direção paralela às fibras do que perpendicularmente às mesmas. Essa propriedade permite a reconstrução digital das trajetórias das fibras, técnica denominada tractografia, representando uma das poucas formas não invasivas de investigação da conectividade anatômica e organização estrutural do cérebro e do coração. A metodologia de tractografia mais difundida faz uso da integração numérica da direção principal de difusividade para reconstruir essas trajetórias. Porém, esta técnica apresenta problemas como o erro intrínseco a métodos de integração numérica e o erro associado a regiões de incerteza nos dados de difusividade. Uma metodologia considerada mais robusta consiste da modelagem da tractografia como a simulação de um sistema de partículas. No entanto, tal metodologia possui diversos parâmetros que precisam ser otimizados para cada caso e apresenta alta complexidade computacional. Esta dissertação apresenta uma metodologia de tractografia global baseada em sistema de partículas, mas com custo computacional reduzido pois evita passos desnecessários da otimização para reconstrução das trajetórias. Avaliamos sua acurácia em conjuntos de dados com graus de complexidade crescentes utilizando imagens sintéticas de difusão construídas digitalmente e em imagens reais de difusão do miocárdio humano. Nesses testes foram observadas reduções no consumo de tempo e maior acurácia para metodologia global apresentada com relação às descritas na literatura. Essa metodologia possui o potencial de evidenciar a organização e arquitetura de diversos tecidos do corpo humano com maior fidelidade e menor tempo de reconstrução.
Title in English
A global tractography method using diffusion magnetic resonance imaging
Keywords in English
Diffusion magnetic resonance images
Particle simulation
Tractography
Abstract in English
The diffusion magnetic resonance imaging portray the diffusivity of water molecules present on biological tissues. High organized and compact biological structures like neuronal fibres and muscles present higher diffusivity parallel to the fibres than perpendicular to those. This property allows the digital reconstruction of fibres trajectories, technique named tractography, being one of the few non invasive ways of investigation of the anatomical connectivity and structural organization of the brain and heart. The most common tractography methodology uses numerical integration following the main diffusion direction in order to reconstruct trajectories. Yet, this technique is prone to intrinsic error to numeric integration and the error associated to uncertainty regions on diffusion data. A methodology considered more robust to such problems consists on modelling tractography as a particle system simulation. However, such methodology has several parameters that require fine tuning for each case and has a high computational complexity. This dissertation presents a global tractography methodology based on particle system but at lower computational cost because of the avoidance of unnecessary optimization steps on trajectory reconstruction. We evaluate its accuracy on synthetic diffusion datasets of increasing complexity and on real human cardiac diffusion images. Theses tests evidence reduced time consumption and increased accuracy for the presented methodology compared to the ones described in the literature. This methodology has the potential to reveal the organization and architecture of several tissues from the human body with higher fidelity and lower reconstruction time.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
main.pdf (24.82 Mbytes)
Publishing Date
2017-05-29
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.