• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.44.2004.tde-15052008-084945
Document
Author
Full name
Margareth Sugano Navarro
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2004
Supervisor
Committee
Ulbrich, Horstpeter Herberto Gustavo Jose (President)
Enzweiler, Jacinta
Nardy, Antonio Jose Ranalli
Title in Portuguese
A implantação de rotina, e seu refinamento, para a determinação de elementos Terras Raras em materiais geológicos por ICP-OES e ICP-MS. Aplicação ao caso dos granitóides de Piedade-Ibiúna (SP) e Cunhaporanga (PR)
Keywords in Portuguese
Análise de rochas
Elementos terras raras
ICPMS
Abstract in Portuguese
No presente trabalho são descritas as etapas de desenvolvimento e implantação das rotinas analíticas utilizando ICP-OES e ICP-MS para a determinação de elementos terras raras em materiais geológicos. A implantação inclui determinações comparativas de vários granitóides dos maciços ou complexos Ibiúna-Piedade, SP, e Cunhaporanga, PR, já previamente analisados por meio de ICP-MS e INAA (Universidade Kansas, em Lawrence, USA). Através de uma pequena modificação no método inicial, os limites de detecção para a análise dos ETR por ICP-OES foram melhorados para concentrações próximas à 10 vezes o condrito. Porém para a análise de ETR em materiais geológicos com valores inferiores a estes é necessária a utilização de uma técnica mais sensível como o ICP-MS. A técnica ICP-MS não é livre de problemas sendo necessárias correções de interferências moleculares e drift instrumental para a obtenção de resultados com precisão e exatidão adequados. Realizou-se a etapa de validação do método utilizando materiais de referência internacionais geológicos. A análise estatística dos resultados obtidos utilizando três métodos de abertura de amostra (ataque ácido em forno de microondas, em bombas tipo Parr e fusão alcalina) mostrou a possibilidade de utilização do ataque ácido em forno de microondas e da fusão alcalina com posterior separação cromatográfica como alternativas eficientes para a determinação de ETR apesar da baixa eficiência nas recuperações dos elementos Zr e Hf em rochas ácidas e gnáissicas equivalentes.
Title in English
The routine development to determination of Rare Earth elements in geological materials by ICP-OES and ICP-MS. Aplictaion in granitoid rocks from Piedade-Ibiúna (SP) and Cunhaporanga (PR) complexes
Keywords in English
ICPMS
Rare earth elements
Rock analysis
Abstract in English
The steps for the development of the analytical routines leading to the determination of the rare earth elements (REE) with the use of ICP-AES and ICP-MS techniques are discussed in this contribution. The set-up of these routines was also evaluated with determinations of REE in several granitoid rocks from the Piedade-Ibiuna (SP) and Cunhaporanga (PR) complexes, and the results compared with those obtained in other laboratories (University of Kansas, Lawrence) with ICP-MS and INAA. The work previously performed for the adaptation of REE determination with ICPAES was reviewed, allowing analyses to be realized with better results for concentrations close to 10 times the chondrite value. At lower concentrations, REE analysis have to be performed with ICP-MS. The ICP-MS technique shows much better accuracy and precision than ICPAES, but presents problems of its own. Instrumental drift corrections, as well as corrections due to molecular interferences, are mandatory. Evaluation of the successfully adapted routines was realized analyzing international reference materials several times and applying statistical tests. A comparison of results with three dissolution techniques (acid attack in microwave oven, use of Parr type bombs, and alkaline fusion with borates) showed that both acid attack and alkaline fusion with later chromatographic separation are rather efficient alternatives for the determination of REE, although Zr and Hf are not fully recovered in many acid igneous and equivalent gneissic rocks.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
MSN.pdf (1.94 Mbytes)
Publishing Date
2008-05-15
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.