• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.44.1997.tde-26092014-161652
Document
Auteur
Nom complet
Sérgio Benjamin Baggio
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 1997
Directeur
Jury
Reboucas, Aldo da Cunha (Président)
Mendes, Jose Milton Benetti
Quadros, Eda Freitas de
Titre en portugais
Água Subterrânea em Joinville - SC - Avaliação hidrogeológica do aqüífero fraturado
Mots-clés en portugais
Hidrogeologia
Resumé en portugais
As águas subterrâneas são nossas reservas mais importantes e representam 97% da água doce disponível no mundo. Joinville é uma cidade em que a precipitação pluviométrica é uma das mais altas do País, em torno de 2.000 mm/ano. A média anual de ocorrência de chuvas está em torno de 200 dias. Apesar deste aporte hídrico, a distribuição de água apresenta sérios problemas, e o racionamento ou a falta de água, ainda é uma constante no dia a dia dos habitantes da cidade de Joinville. Na região as águas subterrâneas estão acumuladas no Aqüífero Fraturado, representado geologicamente por Rochas do Escudo Catarinense, onde o manto de intemperismo atinge em média 40 m de espessura. Este aqüífero está compartimentado em duas direções principais N30-40E e N20-30W. A produtividade dos poços bem locados está em torno de 10 metros cúbicos por hora. A recarga da água estocada no aqüífero fraturado atualmente alcança aproximadamente 31 milhões de m³ por ano. A exploração atual de água subterrânea atinge aproximadamente 3 milhões de metros cúbicos por ano o que representa 10% da recarga. Para a Bacia do Rio Cubatão a recarga estimada chega a 325 milhões de metros cúbicos de água por ano. Com relação à qualidade da água, as análises realizadas pelo Instituto Tecnológico do Paraná - TECPAR, mostram que as águas subterrâneas de Joinville podem ser localmente definidas como águas alcalinas bicarbonatadas, e ainda não existem problemas de contaminação sanitária. Este aqüífero é uma nova alternativa complementar ao recurso hídrico superficial. É estrategicamente a maior reserva de água potável da cidade e representa uma excelente opção, haja visto que seus mananciais encontram-se relativamente melhor protegidos dos efeitos da poluição. Por estas características poderá ser a futura fonte complementar de água para a coletividade Joinvilense, se forem mantidas as atuais condições de proteção das suas áreas de recarga.
Titre en anglais
Not available.
Mots-clés en anglais
Not available.
Resumé en anglais
The groundwater are the most important reserves and represents 97% of the fresh water in the world. The increasing necessity of good quality water is, and will be, the reason for a large number of studies and investments. The city of Joinville is located northeastern of the state of Santa Catarina horing the geografic coordenates 26°18'05" South Latitude and 48°50'38" Longitude West of Greenwich Meridian. The local pluvial precipitation is one of the highest in Brazil, about 2,000 mm/year. The annual rain precipitation distribution is about 200 days. In spite of such water surplus its irregular distribution presents serious problems and the lack of, and rationing of water are still a constant nowadays among the city's population. In its region the groundwater is situated in the fissured rock zones, geologicaly represented by rocks, of Escudo Catarinense, where the weathered zones reaches at about 40m length. Such aquifer is located in fractured zones into two main directions: N30° - 40°E and N20°-30°W. The well production is around l,0 - 3,0 m³/h, due to the lack of criterious for its location. This amount could be 10 m³/h if improved hydrogeological studies. The amount of water utilized from the fissured aquiferous reaches approximately 3.000.000 m³/year. With relation to the water quality, the analyses made by the Paraná Tecnological Institute (Instituto Tecnológico do Paraná - TECPAR) shows that Joinville's groundwater can be defined as a mineral water and there's no problems of organic contamination yet. There are no doubts that the aquifer is a needed alternative to the Rivers Cubatão and Piraí. lts is strategically the largest reserve of potable water for the city and represents an excellent option, taking into consideration that this option is the one most protected from the effects of the polution.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Baggio_Mestrado.pdf (15.45 Mbytes)
Date de Publication
2014-09-29
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.